Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Power Reactor Status Report for December 3, 2012

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100     *  
Calvert Cliffs 2 100        
FitzPatrick 75   DEFISHING WATERBOXES *  
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100   138 KV FEEDER (LINE 33332) OOS    
Indian Point 3 100   138 KV FEEDER (LINE 33332LM) OOS    
Limerick 1 100        
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 0 11/30/2012 MAINTENANCE OUTAGE FOR TURBINE VIBRATION *  
Nine Mile Point 2 100        
Oyster Creek 22   VOLTAGE REGULATOR TESTING *  
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 100        
Seabrook 1 100        
Susquehanna 1 100        
Susquehanna 2 95   INCREASING POWER *  
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 16   TURBINE TESTING *  
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 100        
Brunswick 2 100     *  
Catawba 1 0 11/24/2012 REFUELING OUTAGE *  
Catawba 2 100        
Crystal River 3 0 09/25/2009 DEFUELED - CONT. TENSIONING ON HOLD    
Farley 1 100        
Farley 2 90   GOVERNOR VALVE TESTING *  
Harris 1 100        
Hatch 1 100        
Hatch 2 100        
McGuire 1 100        
McGuire 2 45   VOLTAGE REGULATOR TESTING *  
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100     *  
Saint Lucie 1 100        
Saint Lucie 2 89   HOLDING POWER - HTR DRAIN PUMP MAINTENANCE *  
Sequoyah 1 100   GRID YELLOW FOR SCHEDULED SWYD MAINTENANCE *  
Sequoyah 2 0 10/14/2012 DEFUELED GRID YELLOW FOR SCHEDULED SWYD MAINTENANCE *  
Summer 0 10/12/2012 EXITING REFUELING OUTAGE    
Surry 1 100        
Surry 2 5   HOLD FOR GENERATOR PREPS *  
Turkey Point 3 95   PREPARING TO INCREASE POWER *  
Turkey Point 4 0 11/04/2012 DEFUELED - REFUELING OUTAGE    
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 100        
Dresden 3 0 11/12/2012 REFUELING OUTAGE    
Duane Arnold 0 12/01/2012 GENERATOR FIELD GROUND ISSUE    
Fermi 2 0 11/07/2012 FORCED OUTAGE - SEE EN #48487    
Kewaunee 100        
La Salle 1 100        
La Salle 2 100     *  
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 76   INCREASING POWER *  
Prairie Island 1 0 10/22/2012 DEFUELED - REFUELING OUTAGE    
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100        

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 90   HOLD - CONDENSER AIR INLEAKAGE    
Diablo Canyon 1 50   CONDENSER TUBE CLEANING    
Diablo Canyon 2 100        
Fort Calhoun 0 04/09/2011 DEFUELED - REFUELING OUTAGE    
Grand Gulf 1 100        
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100     *  
River Bend 1 100        
San Onofre 2 0 01/09/2012 REFUELING OUTAGE    
San Onofre 3 0 01/31/2012 DEFUELED - FORCED OUTAGE - S/G REPAIR    
South Texas 1 100        
South Texas 2 100        
Waterford 3 0 10/17/2012 DEFUELED - REFUELING OUTAGE    
Wolf Creek 1 100        

Page Last Reviewed/Updated Tuesday, August 25, 2026

Page Last Reviewed/Updated Tuesday, August 25, 2026