Skip to main content

Power Reactor Status Report for August 22, 2010

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 100        
Calvert Cliffs 2 100        
FitzPatrick 96   COASTDOWN TO REFUELING OUTAGE *  
Ginna 100        
Hope Creek 1 93   REDUCED POWER DUE TO CONDENSER BACKPRESSURE *  
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 100        
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100        
Oyster Creek 100        
Peach Bottom 2 96   COASTDOWN TO REFUELING OUTAGE *  
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 100        
Seabrook 1 100        
Susquehanna 1 100        
Susquehanna 2 94   100% ELECTRICAL CAPABILITY    
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 70   LIMITED BY COOLING WATER DISCHARGE TEMPERATURES    
Browns Ferry 2 62   LIMITED BY COOLING WATER DISCHARGE TEMPERATURES    
Browns Ferry 3 68   LIMITED BY COOLING WATER DISCHARGE TEMPERATURES    
Brunswick 1 100        
Brunswick 2 100        
Catawba 1 100        
Catawba 2 100        
Crystal River 3 0 09/25/2009 DEFUELED    
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100        
Hatch 2 99   INCREASING POWER TO 100% *  
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 85   ONE CIRC WATER PUMP OUT OF SERVICE    
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 100        
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 54   INCREASING POWER *  
Braidwood 2 10   PREPARING TO ROLL TURBINE *  
Byron 1 100        
Byron 2 100        
Clinton 97   100% ELECTRICAL CAPABILITY    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 100        
Dresden 2 100        
Dresden 3 100        
Duane Arnold 98   HOLDING *  
Fermi 2 100        
Kewaunee 100        
La Salle 1 100        
La Salle 2 100        
Monticello 95   REDUCED POWER TO EVALUATE FEEDWATER HEATER TUBE LEAKS. *  
Palisades 100        
Perry 1 100     *  
Point Beach 1 100     *  
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 100        
Quad Cities 2 100     *  

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 100        
Cooper 100        
Diablo Canyon 1 100   230 KV STANDBY LINE OUTAGE    
Diablo Canyon 2 100   230 KV STANDBY LINE OUTAGE    
Fort Calhoun 100        
Grand Gulf 1 88   TURBINE STOP VALVE TESTING *  
Palo Verde 1 100        
Palo Verde 2 100        
Palo Verde 3 100        
River Bend 1 100        
San Onofre 2 100     *  
San Onofre 3 100        
South Texas 1 13   STABLE - PREPARING TO ROLL TURBINE *  
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

Page Last Reviewed/Updated Tuesday, August 25, 2026

Page Last Reviewed/Updated Tuesday, August 25, 2026