Skip to main content

Power Reactor Status Report for January 25, 2004

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100     *  
Calvert Cliffs 1 100        
Calvert Cliffs 2 0 01/23/2004 MANUAL REACTOR TRIP. SEE EN# 40472.    
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 100   COASTING DOWN TO REFUELING    
Limerick 2 100        
Millstone 2 100        
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 98   COASTING DOWN FOR REFUELING *  
Oyster Creek 100     *  
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 99        
Seabrook 1 100        
Susquehanna 1 91   COASTDOWN TO REFUELING OUTAGE.    
Susquehanna 2 100        
Three Mile Island 1 100        
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 03/03/1985 DEFUELED    
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 94   COASTDOWN TO REFUELING OUTAGE    
Brunswick 2 97     *  
Catawba 1 100        
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 92   COASTDOWN TO REFUELING *  
Hatch 2 100   100% ELECTRICAL CAPABILITY *  
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 100        
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 0 01/15/2004 START UP IN PROGRESS *  
Summer 100        
Surry 1 100        
Surry 2 100        
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 100        
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 95   INCREASING POWER *  
Byron 1 100        
Byron 2 100        
Clinton 80   COASTDOWN TO REFUELING OUTAGE    
D.C. Cook 1 100        
D.C. Cook 2 100        
Davis-Besse 0 02/15/2002 MAINTENANCE OUTAGE    
Dresden 2 95   100% ELECTRICAL CAPABILITY *  
Dresden 3 2   INCREASING POWER *  
Duane Arnold 93   100% ELECTRICAL CAPABILITY    
Fermi 2 100        
Kewaunee 0 01/16/2004 SHUT DOWN DUE TO SI BEING OUT OF SERVICE - SEE EVENT #40452    
La Salle 1 0 01/13/2004 REFUELING OUTAGE    
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 100        
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 85   LIMITED IN POWER (STEAM DRYER MONITORING).    
Quad Cities 2 81   SHUFFLING CONTROL RODS *  

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 100        
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 60   REPAIRING MAIN CONDENSER TUBES *  
Comanche Peak 1 100        
Comanche Peak 2 99        
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 99   T-HOT LIMITED *  
Palo Verde 2 98        
Palo Verde 3 99   T-HOT LIMITED    
River Bend 1 100        
San Onofre 2 100        
San Onofre 3 0 01/24/2004 REPAIRING PRIMARY SYSTEM LEAK ON LETDOWN REGENERATIVE HEAT EXCHANGER *  
South Texas 1 0 01/23/2004 AUTO REACTOR TRIP - SEE EVENT #40473    
South Texas 2 100        
Waterford 3 100        
Wolf Creek 1 100        

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021