Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Power Reactor Status Report for November 24, 2003

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Beaver Valley 1 100        
Beaver Valley 2 100        
Calvert Cliffs 1 97   REDUCED POWER FOR BOP MAINTENANCE    
Calvert Cliffs 2 100        
FitzPatrick 100        
Ginna 100        
Hope Creek 1 100        
Indian Point 2 100        
Indian Point 3 100        
Limerick 1 100        
Limerick 2 100        
Millstone 2 0 10/11/2003 RETURNING FROM REFUELING OUTAGE    
Millstone 3 100        
Nine Mile Point 1 100        
Nine Mile Point 2 100     *  
Oyster Creek 100        
Peach Bottom 2 100        
Peach Bottom 3 100        
Pilgrim 1 100        
Salem 1 100        
Salem 2 0 10/09/2003 MANUAL REACTOR TRIP - SEE EN #40350 * 1
Seabrook 1 100        
Susquehanna 1 100     *  
Susquehanna 2 100     *  
Three Mile Island 1 0 10/18/2003 COOLDOWN FOR RCS MAINTENANCE *  
Vermont Yankee 100        

Region 2

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Browns Ferry 1 0 03/03/1985 DEFUELED    
Browns Ferry 2 100        
Browns Ferry 3 100        
Brunswick 1 93   100% ELECTRICAL CAPABILITY    
Brunswick 2 96   100% ELECTRICAL CAPABILITY    
Catawba 1 0 11/07/2003 DEFUELED    
Catawba 2 100        
Crystal River 3 100        
Farley 1 100        
Farley 2 100        
Harris 1 100        
Hatch 1 100     *  
Hatch 2 75   REDUCED POWER FOR CRD EXERCISE AND BOP MAINTENANCE *  
McGuire 1 100        
McGuire 2 100        
North Anna 1 100        
North Anna 2 100        
Oconee 1 0 09/19/2003 REFUELING OUTAGE    
Oconee 2 100        
Oconee 3 100        
Robinson 2 100        
Saint Lucie 1 100        
Saint Lucie 2 100        
Sequoyah 1 100        
Sequoyah 2 0 11/09/2003 REFUELING OUTAGE *  
Summer 1   RETURNING FROM REFUELING OUTAGE *  
Surry 1 100        
Surry 2 0 11/22/2003 MAIN GENERATOR INSPECTION - SEAL OIL SYSTEM    
Turkey Point 3 100        
Turkey Point 4 100        
Vogtle 1 95   INCREASING POWER *  
Vogtle 2 100        
Watts Bar 1 100        

Region 3

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Braidwood 1 100        
Braidwood 2 100        
Byron 1 100        
Byron 2 100        
Clinton 89   COASTDOWN TO REFUELING OUTAGE *  
D.C. Cook 1 0 10/17/2003 REFUELING OUTAGE *  
D.C. Cook 2 100        
Davis-Besse 0 02/15/2002 MAINTENANCE OUTAGE    
Dresden 2 97   100% ELECTRICAL CAPABILITY *  
Dresden 3 86   STEAM DRYER CONCERNS HOLDING PRE-EPU POWER LEVELS *  
Duane Arnold 0 11/18/2003 MAINTENANCE OUTAGE    
Fermi 2 100        
Kewaunee 100        
La Salle 1 100        
La Salle 2 100        
Monticello 100        
Palisades 100        
Perry 1 75   INCREASING POWER *  
Point Beach 1 100        
Point Beach 2 100        
Prairie Island 1 100        
Prairie Island 2 100        
Quad Cities 1 0 11/11/2003 FORCED OUTAGE FOR STEAM DRYER MAINTENANCE    
Quad Cities 2 96   100% ELECTRICAL CAPABILITY *  

Region 4

Unit Power Down Reason or Comment Change in report (*) Number of Scrams (#)
Arkansas Nuclear 1 0 11/15/2003 MAIN XFMR REPAIRS    
Arkansas Nuclear 2 100        
Callaway 100        
Columbia Generating Station 100        
Comanche Peak 1 100        
Comanche Peak 2 99   100% ELECTRICAL CAPABILITY    
Cooper 100        
Diablo Canyon 1 100        
Diablo Canyon 2 100        
Fort Calhoun 100        
Grand Gulf 1 100        
Palo Verde 1 98   T-HOT LIMITED    
Palo Verde 2 0 09/26/2003 REFUELING OUTAGE *  
Palo Verde 3 99   T-HOT LIMITED    
River Bend 1 100        
San Onofre 2 100        
San Onofre 3 100        
South Texas 1 100        
South Texas 2 100        
Waterford 3 85   INCREASING POWER *  
Wolf Creek 1 0 10/18/2003 REFUELING OUTAGE    

Page Last Reviewed/Updated Wednesday, March 24, 2021