The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Power Reactor Status Report for April 7, 2001

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BEAVER VALLEY 1 100        
BEAVER VALLEY 2 100   UNUSUAL EVENT DECLARED DUE TO FIRE IN EXHAUST HOOD DUCTING - SEE EVENT #37897 *  
CALVERT CLIFFS 1 100        
CALVERT CLIFFS 2 0 03/16/2001 REFUELING OUTAGE *  
FITZPATRICK 1 100        
GINNA 1 100        
HOPE CREEK 1 100        
INDIAN POINT 2 100        
INDIAN POINT 3 100        
LIMERICK 1 100        
LIMERICK 2 0 04/04/2001 REFUELING OUTAGE *  
MILLSTONE 2 100        
MILLSTONE 3 100        
NINE MILE POINT 1 0 03/18/2001 REFUELING OUTAGE *  
NINE MILE POINT 2 100        
OYSTER CREEK 1 100        
PEACH BOTTOM 2 100        
PEACH BOTTOM 3 100        
PILGRIM 1 100        
SALEM 1 0 04/06/2001 REFUELING OUTAGE *  
SALEM 2 100        
SEABROOK 1 100        
SUSQUEHANNA 1 100        
SUSQUEHANNA 2 0 03/09/2001 REFUELING OUTAGE *  
THREE MILE ISLAND 1 100        
VERMONT YANKEE 1 100        

Region 2

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BROWNS FERRY 1 0 03/03/1985 DEFUELED    
BROWNS FERRY 2 0 03/18/2001 REFUELING OUTAGE *  
BROWNS FERRY 3 100        
BRUNSWICK 1 100        
BRUNSWICK 2 100        
CATAWBA 1 100        
CATAWBA 2 100        
CRYSTAL RIVER 3 100        
FARLEY 1 100        
FARLEY 2 0 02/24/2001 REFUELING OUTAGE - DEFUELED    
HARRIS 1 100        
HATCH 1 100        
HATCH 2 100        
MCGUIRE 1 0 03/09/2001 REFUELING OUTAGE *  
MCGUIRE 2 100        
NORTH ANNA 1 100        
NORTH ANNA 2 0 03/10/2001 REFUELING OUTAGE    
OCONEE 1 100        
OCONEE 2 100        
OCONEE 3 0 02/16/2001 MAINTENANCE OUTAGE    
ROBINSON 2 0 04/06/2001 REFUELING OUTAGE - RCS COOLDOWN IN PROGRESS *  
SAINT LUCIE 1 0 04/02/2001 REFUELING OUTAGE *  
SAINT LUCIE 2 100        
SEQUOYAH 1 100        
SEQUOYAH 2 100        
SUMMER 1 100        
SURRY 1 100        
SURRY 2 100        
TURKEY POINT 3 100        
TURKEY POINT 4 100        
VOGTLE 1 100        
VOGTLE 2 93   COASTDOWN TO REFUELING OUTAGE    
WATTS BAR 1 100        

Region 3

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
BRAIDWOOD 1 100     *  
BRAIDWOOD 2 100        
BYRON 1 100        
BYRON 2 0 04/06/2001 REFUELING OUTAGE - CURRENTLY HOLDING RCS TEMP FOR SG HIDEOUT STUDY *  
CLINTON 1 100        
COOK 1 100        
COOK 2 100        
DAVIS BESSE 1 100        
DRESDEN 2 22   INCREASING POWER *  
DRESDEN 3 100        
DUANE ARNOLD 1 100        
FERMI 2 100        
KEWAUNEE 1 96   MAXIMUM POWER LEVEL DUE TO PLUGGED STEAM GENERATOR TUBES    
LASALLE 1 100        
LASALLE 2 0 04/06/2001 AUTOMATIC TURBINE TRIP/REACTOR SCRAM ON HIGH WATER LEVEL DUE TO BLOWN FUSE - SEE EVENT #37895 * 1
MONTICELLO 1 100        
PALISADES 1 0 03/30/2001 REFUELING OUTAGE - REDUCED INVENTORY *  
PERRY 1 20   REDUCED POWER FOR BALANCING TURBINE BEARING - GENERATOR OFFLINE *  
POINT BEACH 1 0 04/06/2001 REFUELING OUTAGE - BORATING PRIOR TO RCS COOLDOWN *  
POINT BEACH 2 100        
PRAIRIE ISLAND 1 100        
PRAIRIE ISLAND 2 40   REDUCED POWER FOR CONDENSER TUBE CLEANING *  
QUAD CITIES 1 100        
QUAD CITIES 2 100        

Region 4

Unit Power Down Reason or Comment Change in report(*) Number of Scrams(#)
ARKANSAS NUCLEAR 1 0 03/16/2001 REFUELING OUTAGE    
ARKANSAS NUCLEAR 2 100        
CALLAWAY 1 0 04/06/2001 REFUELING OUTAGE *  
COLUMBIA GENERATING 100     *  
COMANCHE PEAK 1 0 03/24/2001 REFUELING OUTAGE - DEFUELED    
COMANCHE PEAK 2 100        
COOPER 1 100        
DIABLO CANYON 1 100     *  
DIABLO CANYON 2 100     *  
FT CALHOUN 1 0 03/15/2001 REFUELING OUTAGE - DEFUELED    
GRAND GULF 1 100        
PALO VERDE 1 0 03/31/2001 REFUELING OUTAGE - RESOLUTION OF ISSUE INVOLVING A STUCK CONTROL ELEMENT ASSEMBLY IN PROGRESS    
PALO VERDE 2 99        
PALO VERDE 3 99     *  
RIVER BEND 1 64   REDUCED POWER FOLLOWING TRIP OF THE "A" RECIRC PUMP *  
SAN ONOFRE 2 100        
SAN ONOFRE 3 0 02/03/2001 MAINTENANCE OUTAGE    
SOUTH TEXAS 1 100        
SOUTH TEXAS 2 98     *  
WATERFORD 3 100        
WOLF CREEK 1 100        

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.

Page Last Reviewed/Updated Thursday, March 25, 2021