Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Beaver Valley 1 100
Beaver Valley 2 100
Calvert Cliffs 1 100
Calvert Cliffs 2 100
FitzPatrick 50 HOLDING POWER FOR REPLACEMENT OF "B" REACTOR FEED PUMP SEAL
Ginna 100
Hope Creek 1 100
Indian Point 2 0 2000-02-15 REFUELING OUTAGE
Indian Point 3 100
Limerick 1 100
Limerick 2 100
Millstone 2 100
Millstone 3 100
Nine Mile Point 1 100
Nine Mile Point 2 100
Oyster Creek 0 2000-08-15 MAINTENANCE OUTAGE
Peach Bottom 2 87 COASTDOWN TO REFUELING OUTAGE
Peach Bottom 3 100
Pilgrim 1 100
Salem 1 100
Salem 2 100
Seabrook 1 100
Susquehanna 1 100
Susquehanna 2 0 2000-08-17 MAINTENANCE OUTAGE *
Three Mile Island 1 100
Vermont Yankee 100

Region 2

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Browns Ferry 1 0 1985-03-03 DEFUELED
Browns Ferry 2 100
Browns Ferry 3 100
Brunswick 1 100
Brunswick 2 100
Catawba 1 100
Catawba 2 100
Crystal River 3 82 REDUCED POWER FOR "D" WATERBOX CLEANING *
Farley 1 100
Farley 2 100 *
Harris 1 100
Hatch 1 100
Hatch 2 100
McGuire 1 100
McGuire 2 81 COASTDOWN TO REFUELING OUTAGE *
North Anna 1 100
North Anna 2 100
Oconee 1 100
Oconee 2 100
Oconee 3 100
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 100 *
Sequoyah 1 100
Sequoyah 2 100
Summer 100
Surry 1 100
Surry 2 100
Turkey Point 3 100
Turkey Point 4 100
Vogtle 1 98 COASTDOWN TO REFUELING OUTAGE *
Vogtle 2 100
Watts Bar 1 89 COASTDOWN TO REFUELING OUTAGE

Region 3

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Braidwood 1 100
Braidwood 2 100
Byron 1 100
Byron 2 100
Clinton 100
D.C. Cook 1 0 1997-09-08 REFUELING OUTAGE - DEFUELED
D.C. Cook 2 100
Davis-Besse 100
Dresden 2 100
Dresden 3 97 COASTDOWN TO REFUELING OUTAGE *
Duane Arnold 100
Fermi 2 100
Kewaunee 94 MAXIMUM POWER DUE TO PLUGGED STEAM GENERATOR TUBES
La Salle 1 100
La Salle 2 100
Monticello 100
Palisades 99 *
Perry 1 98
Point Beach 1 100
Point Beach 2 100
Prairie Island 1 100
Prairie Island 2 100
Quad Cities 1 98 *
Quad Cities 2 100

Region 4

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Arkansas Nuclear 1 100
Arkansas Nuclear 2 97 *
Callaway 100
Columbia Generating Station 60 SINGLE LOOP OPERATION FOR PUMP REPAIR *
Comanche Peak 1 100
Comanche Peak 2 100
Cooper 100
Diablo Canyon 1 100
Diablo Canyon 2 100
Fort Calhoun 100
Grand Gulf 1 100
Palo Verde 1 98 REDUCED POWER FOR HIGH RATE SG BLOWDOWN *
Palo Verde 2 100
Palo Verde 3 99
River Bend 1 100
San Onofre 2 100
San Onofre 3 100
South Texas 1 100
South Texas 2 100
Waterford 3 100
Wolf Creek 1 100