Skip to main content

Part 21 Report - 1998-174

LICENSEE: ILLINOIS POWER CO. SITE: CLINTON 1 EN NUMBER:34294 DOCKET: 05000461 EVENT DATE: 05-28-98 RX TYPE: BWR EVENT TIME: 10:00 VENDORS: GE-6 NOTIFY DATE: 05-28-98 EMERGENCY CLASS: N/A REGION: 3 STATE: IL TIME: 12:15 OPS OFFICER: FANGIE JONES 10 CFR SECTION: CDEG 21.21(c)(3)(i) DEFECTS/NONCOMPLIANCE UNIT SCRAM RX INIT INITIAL MODE CURR CURRENT MODE CODE CRIT PWR PWR 1 N N 0 COLD SHUTDOWN 0 COLD SHUTDOWN 10 CFR PART 21 FINAL REPORT REGARDING WESTINGHOUSE MODEL DHP CIRCUIT BREAKER AUXILIARY SWITCH OPERATING ASSEMBLY ANOMALIES ON JANUARY 16, 1998, ILLINOIS POWER (IP) ISSUED 10CFR21 INTERIM REPORT 21-97-055 IN LETTER U-602910. THIS NOTIFIED THE NRC THAT AN EVALUATION UNDER THE PROVISIONS OF PART 21 OF 10CFR WAS NOT COMPLETE FOR ANOMALIES IN SAFETY-RELATED WESTINGHOUSE MODEL DHP CIRCUIT BREAKER AUXILIARY SWITCH OPERATING ASSEMBLIES. IP PROVIDED AN UPDATE IN LETTER U-602968 ON MARCH 24, 1998 TO THE NRC. IP HAS COMPLETED THE EVALUATION OF THIS ISSUE AND CONCLUDES THAT IT SHOULD BE REPORTED UNDER THE PROVISIONS OF 10CFR21. THE BASIS FOR THIS CONCLUSION IS THAT THE ANOMALIES COULD CAUSE A FAILURE OF THE AUXILIARY SWITCH OPERATING ASSEMBLY DURING BREAKER OPERATION, RESULTING IN LOSS OF THE BREAKER SAFETY FUNCTION. THE ANOMALIES INCLUDED FOUR CASES OF BENT AUXILIARY SWITCH LINK AND TWO CASES OF MISSING "E" CLIPS. THE BASIC COMPONENT INVOLVED IN THIS CONDITION IS THE AUXILIARY SWITCH OPERATING ASSEMBLY, INCLUDING THE AUXILIARY SWITCHES, THE OPERATING LINK, AND THE OPERATING CAM (IF APPLICABLE), FOR WESTINGHOUSE MODEL DHP 4160-VOLT AND 6900-VOLT CIRCUIT BREAKERS. THE ASSEMBLY WAS SUPPLIED BY WESTINGHOUSE, PITTSBURGH, PA, AS PART OF MODEL DHP CIRCUIT BREAKERS. CLINTON POWER STATION HAS 43 DHP BREAKERS INSTALLED IN SAFETY-RELATED APPLICATIONS AND 2 SPARE SAFETY-RELATED DHP BREAKERS POTENTIALLY AFFECTED BY THE AUXILIARY SWITCH OPERATING ASSEMBLY DEFICIENCIES. DHP CIRCUIT BREAKERS WILL BE INSPECTED AND REWORKED/REFURBISHED AS NECESSARY PRIOR TO STARTUP FROM THE CURRENT OUTAGE.

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021