Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 1998-139

ACCESSION #: 9808100315 Shared Services Group P.O. Box 3707 Seattle, WA 98124-2207 BOEING July 30, 1998 G-1151-SJA-98-385 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Error notices have been sent to our other former customers. Very truly yours, Sandra J. Andrews Nuclear Administrator Phone: (425) 865-6248 FAX: (425) 865-4851 Mail Stop: 7A-33, or e-mail: Sandra.J.Andrews@Boeing.com Enclosure(s): Georgia Institute of Technology GT STRUDL [Registered Trademark] July 23, 1998 Attention: Nuclear Administrator Boeing Information & Support Services P.O. Box 24346, MS 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find copies of GTSTRUDL PROGRAM REPORT FORM 98.10, 98.11, 98.12, and a GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM. Please sign and return the GTSTRUDL QA CUSTOMER ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTSTRUDL Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgement Form. Best regards, CASE Center David C. Key Configuration Control Manager Enclosures Computer Aided Structural Engineering Center Phone: (404) 894-2260 School of Civil & Environmental Engineering Fax: (404) 894-8014 Atlanta, Georgia 30332-0355 USA casec@ce.gatech.edu A Unit of the University System of Georgia GTSTRUDL Program Report Form GPRF No.: DATE: FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. MINOR Problem can be worked around or problem poses high frustration factor. INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed Date Notification Sent Computers Operating System Version Target Release for Correction Signature Title R & D Division Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: DATE: DESCRIPTION: Under certain circumstances, TYPE STRUCTURAL WALL design can "freeze" GTSTRUDL during a PROPORTION command. A non-terminating iteration is entered and the user must halt (abort) the execution of GTSTRUDL and all data is lost. There is no work-around, but this problem is rare, with one reported instance. Relevant documentation: Section 4.2 The DESIGN DATA Command, Volume 4, GTSTRUDL Reference Guide Section 4.3 The PROPORTION MEMBERS Command, Volume 4, GTSTRUDL Reference Guide Rev 2.2 GTSTRUDL Program Report Form GPRF No.: DATE: FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: X URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. MINOR Problem can be worked around or problem poses high frustration factor. INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed Date Notification Sent Computers ALL Operating System ALL Version 9601,9701,9801 Target Release for Correction 9802 Director, R&D Signature Title R & D Division Kenneth Will Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: DATE: DESCRIPTION: When performing an elastic buckling analysis (PERFORM BUCKLING ANALYSIS command) with more than five active loadings, a value of 0.0 will be output for the Buckling Multiplier for the loads beyond the first five active loadings or an abort may occur. Workaround: Peform the buckling analysis for only five active loadings in each execution. Do not use the Load List command due to GPRF 93.25 still being open. Applicable Sections of the Users Manual Documentation: Perform Buckling Analysis - Section 2.8, Volume 3, GTSTRUDL Users Manual GTSTRUDL Program Report Form GPRF No.: 98. DATE: FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: x URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. MINOR Problem can be worked around or problem poses high frustration factor. INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed July 21, 1998 Date Notification Sent Computers PC, SPARC Operating System All Versions: SPARC: 9601; PC: 9601 and later Target Release for Correction: 99.01 Mgr. ASD Signature Title R & D Division Michael H. Swanger Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev. 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: 98. DATE: DESCRIPTION: The scope environment OVERLAY DIAGRAM/ENVELOPE command may abort if the active loading conditions contain no member loads. A workaround is to explicitly specify the number of sections using the SECTION command prior to entering the scope environment and performing the OVERLAY operation. An example of the SECTION command is given as follows: SECTION FR DS 0.0 0.05 $ Produces 21 sections. GTSTRUDL User Reference Manual Sections: The Scope Environment OVERLAY Command Sections 2.7.6.7, Volume 3, GTSTRUDL Reference Manual. Internal Member Results Output - The SECTION Command Section 2.1.14.5, Volume 1, GTSTRUDL Reference Manual. Rev. 2.2 *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021