United States Nuclear Regulatory Commission - Protecting People and the Environment


ACCESSION #: 9710150086



Coltec Industries                            Fairbanks Morse

                                             Engine Division

                                             701 White Avenue

                                             Beloit, WI 53511-5492

                                             608/364-4411

                                             FAX: 608/364-0382



                             INTERIM LETTER



                     * Addenda: 1, dated 08 OCT 97 *



To: Document Control Desk

     U.S.  Nuclear Regulatory Commission

     Washington, DC.  20555



From: Coltec Industries-Fairbanks Morse Engine Division (FMED)



Date: 30 September 1997 (original issue date)



Subject: Weldments on Opposed Piston and Coltec-Pielstick Emergency

     Stand-By Diesel Gen-Set Lube-Oil and Jacket Water Piping Systems



Upon further investigation, the list of potentially affected unites is

revised to include the asterisked (*) utilities.



Arkansas Nuclear One               Millstone 1 & 2

Calvert Cliffs 1 & 2               North Anna 1 & 2

Crystal River 3                    Peach Bottom 2 & 3

Duane Arnold Energy Center         Plant Hatch 1 & 2

Farley 1 & 2                       Prairie Island 1 & 2

Fermi 2 & 3                        Three Mile Island 2 & 3

* H. B. Robinson 3                 Vermont Yankee



Sincerely,



Scott A.  Fratianne

Sr.  Quality Assurance Engineer



                                   A division of Coltec Industries Inc.





*** END OF DOCUMENT ***