Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Part 21 Report - 1997-301

ACCESSION #: 9705140409 PSE&G Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, New Jersey 08038-0236 Nuclear Business Unit MAY 07 1997 LR-N970289 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 HOPE CREEK GENERATING STATION DOCKET NO. 50-354 UNIT NO. 1 LICENSEE EVENT REPORT NO. 97-007-00 Dear Sir: This Licensee Event Report entitled "Struthers-Dunn 219NE Series Relay Failures Due to Thermal Degradation of Magnetic Vinyl Plastic Bearing Pad Material" is being submitted pursuant to the requirements of 10 CFR 50.73(a)(2)(v) and 10 CFR 21. Sincerely, Mark Bezilla General Manager, Hope Creek Operations PRD/ SORC Mtg. 97-026 C Distribution LER File The power is in your hands. 95-2168 REV 6/94 Document Control Desk LR-N970289 Attachment A The following items represent the commitments that the Public Service Electric and Gas Company is making to the Nuclear Regulatory Commission relative to LER 354/97-007-00: 1. Panels containing Struthers-Dunn 219NE series relays with degraded magnetic vinyl plastic bearing pad material are being inspected weekly to ensure continued operability until the relays are replaced. 2. Struthers-Dunn 219NE series relays with degraded magnetic vinyl plastic bearing pad material will be replaced as soon as possible within the Hope Creek work week schedule. Replacement will be complete before the end of Hope Creek's seventh refueling outage. 3. Normally energized Struthers-Dunn 219NE series 120 VAC (model number 219BBX222NE) and 24 VAC (model number 219BBX232NE) relays with no bearing pad or with non-degraded magnetic vinyl plastic bearing pad material will be inspected to verify no degradation. The results of this inspection will be assessed to determine the need for additional inspections until the relays are replaced. This activity will be completed by August 29, 1997. 4. The SSWS vacuum breaker relays that were omitted from the EQ Program have been added to the program and will be replaced before the end of their qualified life (November 24, 1997). 5. Normally energized Struthers-Dunn 219NE series 120 VAC (model number 219BBX222NE) and 24 VAC (model number 219BBX232NE) relays with no bearing pad or with non-degraded magnetic vinyl plastic bearing pad material will be replaced before the end of their calculated service life (April 15, 1998). *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021