Skip to main content

Part 21 Report - 1997-061

ACCESSION #: 9701290314 LIMITORQUE Corporation January 23, 1997 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION: Document Control Desk SUBJECT: Potential 10 CFR 21 Condition - Counterfeit Component Please be advised that Limitorque has discovered the existence of a counterfeit component installed in a Limitorque actuator at a nuclear power plant. This component is classified as "critical" by Limitorque Corporation. The subject component had failed which resulted in actuator inoperability. The component was sent by the nuclear utility to Limitorque for root cause failure analysis. This analysis revealed that the failed component was not manufactured by Limitorque and was deficient in several critical required attributes. It should be noted that this component was not installed in an actuator required to perform a safety related function. This component was apparently purchased from the "surplus" resale market. This advisory does not follow the normal 10 CFR 21 formatting and is intended to act as a vehicle to alert the appropriate organizations to this potential significant Safety issue. Licensee procurement, material control, etc. procedures should be reviewed to ensure adequate controls are in place to prevent a similar occurrence. Limitorque Corporation P. O. Box 11318 5114 Woodall Road Lynchburg, VA 24506-1318 Tel. (804) 528-4400 FAX (804) 845-9736 Page 2 January 23, 1997 Counterfeit Limitorque Actuator Component Any questions on clarifications regarding this notification may be directed Mr. P. McQuillan, Nuclear/Special Projects Manager at (804) 528-4400 Ext 9714, or fax (804) 845-9736. Charles L. Hylton Vice-President of Engineering CLH/lab cc: Part 21 File - Evaluation #57 GENERAL INFORMATION or OTHER EVENT NUMBER: 31665 LICENSEE: LIMITORQUE CORPORATION NOTIFICATION DATE: 01/27/97 CITY: LYNCHBURG REGION: 2 NOTIFICATION TIME: 09:35 [ET] COUNTY: STATE: VA EVENT DATE: 01/27/97 LICENSE#: AGREEMENT: N EVENT TIME: 00:00[EST] DOCKET: LAST UPDATE DATE: 01/27/97 NOTIFICATIONS NRC NOTIFIED BY: HYLTON VERN HODGE NRR HQ OPS OFFICER: CHAUNCEY GOULD EMERGENCY CLASS: NOT APPLICABLE 10 CFR SECTION: NINF INFORMATION ONLY EVENT TEXT LIMITORQUE, HAS DISCOVERED THE EXISTENCE OF A COUNTERFEIT COMPONENT INSTALLED IN A LIMITORQUE ACTUATOR AT A A NUCLEAR POWER PLANT. THE COMPONENT WHICH WAS INSTALLED IS CONSIDERED "CRITICAL" BY LIMITORQUE CORPORATION. THE SUBJECT COMPONENT, WHICH FAILED, WAS SENT TO LIMITORQUE FOR ROOT CAUSE FAILURE ANALYSIS. THE ANALYSIS REVEALED THAT THE FAILED COMPONENT WAS NOT MANUFACTURED BY LIMITORQUE AND WAS DEFICIENT. IT SHOULD BE NOTED THAT THIS COMPONENT WAS NOT INSTALLED IN AN ACTUATOR REQUIRED TO PERFORM A SAFETY RELATED FUNCTION. THE COMPONENT WAS APPARENTLY PURCHASED FROM THE "SURPLUS" RESALE MARKET. *** END OF DOCUMENT ***

Page Last Reviewed/Updated Wednesday, March 24, 2021