Part 21 Report - 1996-760
ACCESSION #: 9611060282 ESI ENGINE SYSTEMS, INC. 1220 South Washington St. Rocky Mount, NC 27801 Phone: (919) 977-2720 Fax: (919) 446-1134 TELEFAX DATE: November 4, 1996 COMPANY: Office of Nuclear Reactor Regulation FAX NUMBER: 301/415-1887 ATTENTION: Vern Hodge REFERENCE: Report 10CFR21-0074 FROM: Michael Nuding Dear Sir: Attached is our report 10CFR21-0074 for a 10CFR21 reportable defect with four excitation contactors (EMD #9562575) supplied by ESI to GPU nuclear. GPU is the only user affected by this notification. Should you have any questions, please let us know. Sincerely, Engine Systems, Inc. Michael Nuding, Manager, Quality Assurance Report No. 10CFR21-0074 NOVEMBER, 4, 1996 10CFR21 REPORTING OF DEFECTS AND NON-COMPLIANCE COMPONENT: "EXC" Contractor, EMD #9562575 SYSTEM: EMD MP-45 diesel generator control systems CONCLUSION: Defect is Reportable in Accordance with 10CFR21 PREPARED BY: DATE: Donald D. Galeazzi Engineering Manager REVIEWED BY: DATE: Michael Nuding General Manager, Quality Assurance REPORT NO. 10CFR21-0074 PAGE: 1 OF 2 SUMMARY Engine Systems, Inc. (ESI) received notification on 10/22/96 from GPU Nuclear about problems with EMD contractor #9562575. ESI had further discussions with GPU (Mr. John Rogers) on 11/4/96. The problems reported by GPU are as follows: 1. A wire jumper was installed between one of the contractor coil terminals and one of the contractor auxiliary contact terminals. This jumper is normally supplied with the contractor from EMD; however, it is not required for the wiring configuration in the GPU diesel generator control system. If left connected on the contractor when installed in the GPU control system, a short circuit is created in the DC control power supply when the contractor is energized (causing the auxiliary contact to close). This condition was present on all four of the contactors supplied by ESI. 2. The connection of the stationary contact arm on the auxiliary contact block was loose. This condition was present on two of the four contactors supplied by ESI. The contractor is designated "EXC" (excitation contractor) and is energized to provide excitation to the generator. COMPONENT EMD contractor #9562575. CUSTOMERS AFFECTED: GPU Nuclear, Oyster Creek is the only user of this contractor is nuclear safety related service. DEFECT 1. A wire jumper was installed between one of the contractor coil terminals and one of the contractor auxiliary contact terminals. This jumper is normally supplied with the contractor from EMD; however, it is not required for the wiring configuration in the GPU diesel generator control system. If left connected on the contractor when installed in the GPU control system, a short circuit is created in the DC control power supply when the contractor is energized (causing the auxiliary contact to close). This condition was present on all four of the contactors supplied by ESI. 2. The connection of the stationary contact arm on the auxiliary contact block was loose. This condition was present on two of the four contactors supplied by ESI. REPORT NO. 10CFR21-0074 PAGE: 2 OF 2 CORRECTIVE ACTION 1. GPU has removed the jumper and tightened the connection screws of the auxiliary contact station arm on all four contactors. 2. ESI has revised the component dedication report to require removal of the jumper and to require checking the auxiliary contact arm screws for tightness. GPU is the only user affected by this notification. All contactors supplied to GPU have been corrected; therefore, no further corrective action is required. *** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021