Part 21 Report - 1995-146
ACCESSION #: 9506140411 The Boeing Company P.O. Box 3707 Seattle, WA 98124-2207 BOEING June 6, 1995 G-1151-RSO-95-232 Document Control Desk United States Nuclear Regulatory Commission Washington, D.C. 20555 Reference: a) Boeing Letter G-1151-RSO-92-365 dated August 31, 1992; R. S. Orr to the NRC Operations Center b) NRC Letter Docket No. 99901227 dated August 12, 1992; L. J. Norrholm to R. S. Orr; Subject: Response to 10 CFR 21 Inquiry Dear Sir or Madam: In accordance with the reference correspondence and 10 CFR 21, Boeing is sending the NRC the attached error notice(s) received from our former software suppliers. Because of unknown current addresses, the following former customers were not notified: Reactor Controls, Inc. Echo Energy Consultants, Inc. Nuclear Applications and Systems Analysis Company (Japan) Nuclear Power Services Error notices have been sent to our other former customers. Very truly yours, R. S. Orr Nuclear Administrator G-1151 M/S 7A-33 (206) 865-6248 Attachment(s): GTICES Program Report Form No. 95.13 Georgia Tech Computer Aided Structural Engineering Center Georgia Institute of Technology School of Civil & Environmental Engineering Atlanta, Georgia 30332-0355 USA 404 o 894 o 2260 404 o 894 o 8014 FAX June 1, 1995 Attention: Nuclear Administrator JUN 06 1995 Boeing Computer Services P.O. Box 24346, M/S 7A-33 Seattle, Washington 98124-0346 RE: GT STRUDL Dear Sir or Madam: Enclosed please find a copy of GTICES PROGRAM REPORT FORM No. 95.13 and a VENDOR ACKNOWLEDGEMENT FORM. Please sign and return the VENDOR ACKNOWLEDGEMENT FORM to acknowledge receipt of the GTICES Program Report. Thank you for reviewing the Program Report and for returning the Acknowledgement Form. Best regards, CASE Center Catherine Lee Configuration Control Manager CL/jhb Enclosures GTSTRUDL Program Report Form GPRF No.: 95.13 DATE: June 1, 1995 FROM: Computer-Aided Structural Engineering Center Georgia Institute of Technology Atlanta, Georgia 30332-0355 SEVERITY LEVEL: - URGENT Problem results in incorrect answers which may not be apparent or job aborts and cannot be recovered within the session or job. - SERIOUS Problem results in incorrect answers which are obvious or problem prevents completion of a particular user's task. x MINOR Problem can be worked around or problem poses high frustration factor. - INFORMATIVE Documentation error, program usage tip, user inconveniences. Date Problem Confirmed June 1, 1995 Date Notification Sent June 2, 1995 Computers All Operating System All Version 93.01 and later. Target Release for Correction 95.02 Manager, ASD Signature Title R & D Division Michael H. Swanger June 1, 1995 Typed or Printed Name Date of Signature Signature Title Professional Services Division Typed or Printed Name Date of Signature Rev 2.2 GTSTRUDL Program Report Form (Continued) GPRF No.: 95.13 DATE: June 1, 1995 DESCRIPTION: The following sequence of commands has been known to cause an abort in the STIFFNESS ANALYSIS command with the MONITOR option: STRUDL . . . STIFFNESS ANALYSIS MONITOR STRUDL . . . STIFFNESS ANALYSIS (abort) Notice the start of a new job with the STRUDL command immediately following the STIFFNESS ANALYSIS MONITOR command. The second STIFFNESS ANALYSIS command produces monitor output prior to the abort in spite of the fact that the MONITOR option is not given. Applicable sections of User's Manual: The STIFFNESS ANALYSIS command Section 2.1.13.2, Volume 1 Rev. 2.2 *** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021