Part 21 Report - 1995-122
ACCESSION #: 9505300156 MKW POWER SYSTEMS, Inc. April 24, 1995 Thomas Murley Director Office of Nuclear Reactor Regulation 11555 Rockville Pike Rockville, MD 20852 Reference: Report No. 10CFR21-0071 Subject: Reportable defect with Square D type KPD relay Dear Mr. Murley: MKW Power Systems was notified on 2/23/95 by Wisconsin Electric - Point Beach about a contact failure of a Square D type KPD this relay used in their diesel generator control panel. Our review of this subject is not yet complete. We estimate a completion date of 5/8/95. An interim report is attached which describes the condition. Yours very truly, MKW POWER SYSTEMS, INC. Michael Nuding General Manager - Quality Assurance MN:dg Enclosure Post Office Box 1928 o Rocky Mount, North Carolina 27802-1928 o Phone: (919) 977-2720 TWX: (510) 929-0725 o FAX: (919) 446-3830 MKW POWER SYSTEMS, Inc. Report No. 10CFR21-0071I April 24, 1995 INTERIM REPORT 10CFR21 REPORTING OF DEFECTS AND NON-COMPLIANCE COMPONENT: Square D Class 8501, Type KPD relay SYSTEM: EMD Diesel Generator control systems CONCLUSION: To be determined PREPARED BY: DATE: Donald D. Galeazzi Engineering Manager APPROVED BY: DATE: Michael Nuding General Manager, Quality Assurance Post Office Box 1928 o Rocky Mount, North Carolina 27802-1928 o Phone: (919) 977-2720 TWX: (510) 929-0725 o FAX: (919) 446-3830 REPORT NO. 10CFR21-0071I PAGE: 1 OF 4 SUMMARY Recent information has revealed a change in published DC contact ratings of Square D type KPD relays . These relays are used by MKW Power Systems in diesel generator 125 VDC control circuits. MKW Power Systems received notification on 2/23/95 from Wisconsin Electric - Point Beach about a contact failure of the BTR (breaker trip relay) within the diesel generator control panel. The contact was wired out for customer use; Wisconsin Electric utilized the relay contact to trip their 86 lockout relay. Investigation by Wisconsin Electric revealed that their circuit required approximately 1.3 amps @ 125 VDC. This lead Wisconsin Electric to verify the contact ratings of the BTR relay (Square D class 8501, type KPD-13). Square D indicated that the KPD-13 relay did not have any DC ratings. MKW Power Systems performed further investigation with Square D which revealed that Square D had recently corrected their catalog to remove the DC ratings. Previous issues of the Square D Digest provided the following contact ratings (see Exhibit 2): 1985: 10A continuous, make/break 60 VA @ 125 VDC. 1990: 10A continuous @ 6-120 VDC. 1992: no DC contact ratings. 1994: no DC contact ratings. According to Square D, the above changes in contact ratings were due to catalog errors; not due to design changes of the KPD-13 relay. MKW Power Systems informed Square D that they have been utilizing the KPD-13 relays in 125 VDC circuits for more than twenty years with successful results and therefore the relays have demonstrated their capability to handle DC loads. Square D contacted their supplier and provided the following ratings (see Exhibit 1): 10A continuous, make/break 50 VA (.4A) @ 125 VDC. Some KPD contacts within the MKW Power Systems' control panels are wired- out to terminals for "customer's use". These contacts are used for applications such as: D/G circuit breaker close, D/G circuit break trip, 86 relay trip, etc.. The above contact make/break ratings are less than the original ratings of 60 VA and therefore users should be notified of this deviation. COMPONENTS Square D class 8501, type KPD relays. KPD-13 (3 pole version) KPD-12 (2 pole version) REPORT NO. 10CFR21-0071I PAGE: 2 OF 4 CUSTOMERS AFFECTED To be determined. DEFECT The defect has been identified as a change in the DC make/break contact rating of the Square D type KPD relay. Square D's most recent publications show the relay as not having any DC contact ratings, but they have verified with their relay supplier that the relay can make/break 0.4 amps (50 VA) and carry 10 amps continuously @ 125 VDC. This make/break rating is less than the originally published rating of 60 VA @ 125 VDC. MKW Power Systems has been utilizing the KPD relay in their 125 VDC control circuitry for more than twenty (20) years. During this time period, contact failures due to excessive current have not been a problem. All customers (except FP&L - Turkey Point and Wisconsin Electric - Point Beach) have at least ten (10) years of operating experience. Because of this operating experience MKW Power Systems does not believe that the described change in contact ratings will affect the operability of its diesel generators in nuclear safety related service. Circuitry for FP&L and Wisconsin Electric control panels is being reviewed to determine if loads beyond the 50 VA contact rating exist. CORRECTIVE ACTION Users should review their circuitry which utilize "customer use" KPD relay contacts and verify that the new contact ratings are not exceeded. For Wisconsin Electric-Point Beach relays SDRX2 and BTR have been identified as being utilized in circuitry which exceeds the 50 VA contact rating. Wisconsin Electric has replaced these relays with ones having adequate contact ratings. REPORT NO. 10CFR21-0071I PAGE: 3 OF 4 EXHIBIT 1 (1 pages) SQUARE D TO MKW POWER SYSTEMS KPD RELAY CONTACT RATINGS FACSIMILE TRANSMITTAL SQUARE D COMPANY AUTOMATION AND CONTROL BUSINESS HIGHWAY 64 EAST, KNIGHTDALE, NC 27545 NUMBER OF PAGES INCLUDING THIS PAGE: 1 IF YOU HAVE NOT RECEIVED ALL PAGES CALL: 919-266-8298. DATE: March 17, 1995 TO: Michael Nuding FAX NO. 919 / 446 - 6112 MKW Power Systems FROM: John Nussbaum - Raleigh Marketing FAX NO. 919 / 266 - 8393 SUBJECT: 8501 KPD13 Relays DC Contact Ratings The 8501 KPD13 relay doesn't have any UL approved DC contact ratings. The information published in our 1990 Digest was incorrect. The information shown in our current Digest is correct. Our supplier has done some in home testing and they say it will make and break 10 amp, at 28 VDC and 0.4 amps, at 125 VDC. The contacts will continuously carry, but not make or break, 10 amps, at 125 VDC. There is no testing available to support a 60 VA rating. I hope this information helps you. If I can be of any further help, please call me at (919) 266 - 8298. Regards, Page 1 REPORT NO. 10CFR21-0071I PAGE: 4 OF 4 EXHIBIT 2 (4 pages) SQUARE D CATALOG PAGES KPD RELAY CONTACT RATINGS (1985, 1990, 1992, 1994) Figure "GENERAL PURPOSE CONTROL RELAYS, TYPE K, CLASS 8501" omitted. Figure "LOGIC PRODUCTS, GENERAL PURPOSE RELAYS, TYPE K -- PLUG-IN, CLASS 8501" omitted. Figure "General Purpose Relays, Type K -- Plug-in Relay, Application Data, Dimensions, Wiring Diagrams, Class 8501", 2 pages, omitted. MKW POWER SYSTEMS, Inc. 301 South Church Street Station Square, Suite 100 Rocky Mount, NC 27804 Phone: (919) 977-2720 TWX: (510) 929-0725 FAX: (919) 446-1134 TELEFAX DATE: April 24, 1995 COMPANY: Office of Nuclear Reactor Regulation FAX NUMBER: 301-415-1887 ATTENTION: Thomas Murley REFERENCE: Interim Report #10CFR21-0071I FROM: Michael Nuding IF YOU DO NOT RECEIVE ALL PAGES LISTED, PLEASE CALL EXTENSION 253. PAGES (INCLUDING COVER SHEET): 12 Dear Sir: Following this cover is a copy of an interim report for the Square D type KPD relay. Should you have questions, please let us know. Sincerely, MKW POWER SYSTEMS, INC. Michael Nuding General Manager-Quality Assurance *** END OF DOCUMENT ***
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021