Morning Report for February 1, 2002
Headquarters Daily Report FEBRUARY 01, 2002 *************************************************************************** REPORT NEGATIVE NO INPUT ATTACHED INPUT RECEIVED RECEIVED HEADQUARTERS X REGION I X REGION II X REGION III X REGION IV X PRIORITY ATTENTION REQUIRED MORNING REPORT - HEADQUARTERS FEB. 01, 2002 MR Number: H-02-0014 NRR DAILY REPORT ITEM GENERIC COMMUNICATIONS Subject: Issuance of Regulatory Issue Summary 2002-02 NRC Regulatory Issue Summary 2002-02: Lessons Learned Related to Recently Submitted Decommissioning Plans and License Termination Plans dated January 16, 2002 The U.S. Nuclear Regulatory Commission is issuing this regulatory issue summary to inform addressees of lessons learned from reviews of recently submitted decommissioning plans and license termination plans. ADAMS Accession No.: ML013510432 Contact: Stewart W. Brown, NMSS 301-415-6605 E-mail: swb1@nrc.gov _ HEADQUARTERS MORNING REPORT PAGE 2 FEBRUARY 1, 2002 MR Number: H-02-0015 NRR DAILY REPORT ITEM GENERIC COMMUNICATIONS Subject: Issuance of Information Notice 2002-07 NRC Information Notice 2002-07: Use of Sodium Hypochlorite for Cleaning Diesel Fuel Oil Supply Tanks dated January 28, 2002 The U.S. Nuclear Regulatory Commission is issuing this information notice to alert addressees to the potential problems related to the use of sodium hypochlorite solutions for cleaning diesel fuel oil supply tanks. Use of this chemical in higher concentrations can cause the release of significant amounts of chlorine gas. ADAMS Accession No.: ML013450182 Contacts: Krzysztof Parczewski, NRR M. Scott Freeman, Region II 301-415-2705 864-822-6927 E-mail: kip@nrc.gov E-mail: msf1@nrc.gov _ HEADQUARTERS MORNING REPORT PAGE 3 FEBRUARY 1, 2002 MR Number: H-02-0016 NRR DAILY REPORT ITEM GENERIC COMMUNICATIONS Subject: Issuance of Information Notice 2002-08 NRC Information Notice 2002-08, Pump Shaft Damage Due to Excessive Hardness of Shaft Sleeve dated January 30, 2002 The U.S. Nuclear Regulatory Commission is issuing this information notice to alert addressees of potentially serious damage that occurred to pump shafts manufactured by Bingham-Willamette. The damage resulted from harder-than-specified material used during the manufacture of the thrust sleeve installed on the pump shaft. ADAMS Accession No.: ML020300002 Contacts: J. Melfi, Region IV B. Elliot, NRR 817-860-8269 301-415-2709 E-mail: jfm1@nrc.gov E-mail: bje@nrc.gov W. Poertner, NRR 301-415-1175 E-mail: wkp@nrc.gov _
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021