Skip to main content

Event Notification Report for November 25, 2026

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/24/2026 - 11/25/2026

EVENT NUMBERS
585385853958548

Hospital
Event Number: 58538
Rep Org: Veterans Health Administration
Licensee: US department of Veteran affairs
Region: 3
City: Little Rock   State: AR
County:
License #: 03-23853-01VA
Agreement: N
Docket:
NRC Notified By: Kim Wiebeck
HQ OPS Officer: Philip Alier
Notification Date: 11/17/2026
Notification Time: 10:11 [ET]
Event Date: 11/16/2026
Event Time: 08:30 [CST]
Last Update Date: 11/17/2026
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(1)(i) - Dose <> Prescribed Dosage
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
EDWARD, RHEX (NMSS R3)
Event Text
MEDICAL EVENT

The following information was provided by the Veterans Health Administration (VHA) via phone and email:

"Central Arkansas Veterans Healthcare System, Little Rock, Arkansas, which holds VHA Permit Number 03-01082-01 under the VA Master Materials License (03-23853-01VA), reported discovery of a medical event to the National Health Physics Program (NHPP) at approximately 1500 CST on November 16, 2026.

"A therapeutic administration of yttrium-90 (Y-90) microspheres (TheraSphere) to segment 8 of the right lobe of a patient's liver was performed at approximately 0830 CST on November 16, 2026. Subsequent measurements and calculations indicated that the patient received approximately 278 Gy, representing 56 percent of the prescribed dose of 500 Gy. The total activity required at administration to deliver 500 Gy was 1.09 GBq (29.5 mCi); the administered activity was estimated to be 0.57 GBq (15.4 mCi). A causal analysis of the medical event is being conducted by the medical center.

''The patient and the referring physician have been notified. At this time, short term harm to the patient is not expected. NHPP plans to perform a reactive inspection to assess causes and regulatory compliance. NHPP will follow up with a written report in accordance with NRC requirements in 10 CFR 35.3045."

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Agreement State
Event Number: 58539
Rep Org: Ohio Department of Health
Licensee: University of Cincinnati Medical
Region: 3
City: Cincinnati   State: OH
County:
License #: 02110310001
Agreement: Y
Docket:
NRC Notified By: Joshua Wagner
HQ OPS Officer: Adam Conklin
Notification Date: 11/17/2026
Notification Time: 14:41 [ET]
Event Date: 11/17/2026
Event Time: 00:00 [EST]
Last Update Date: 11/17/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSC (Canada), (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST SOURCES

The following is a summary of information provided by the Ohio Department of Health, Bureau of Environmental Health and Radiation Protection (ODH) via email:

The licensee in Ohio notified ODH that they did not receive two packages of I-125 seeds (133 mCi/4.921 GBq total). The common carrier had reported the packages delivered, potentially resulting in lost/stolen licensed radioactive material. ODH notified the shipper (IsoAid, Florida license 3196-1), Florida's radiation control program, and the NRC. The licensee never received or took possession of the shipped material, and they appear to be lost in transit. ODH will continue to investigate and provide updates on whether the material is found or delivered as intended.

Ohio Item Number: OH260009

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Power Reactor
Event Number: 58548
Facility: Millstone
Region: 1     State: CT
Unit: [3] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: Joshua Keith
HQ OPS Officer: Adam Conklin
Notification Date: 11/24/2026
Notification Time: 05:50 [ET]
Event Date: 11/24/2026
Event Time: 05:07 [EST]
Last Update Date: 11/24/2026
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(i) - Plant S/D Reqd By TS
Person (Organization):
Glenn Dentel (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 0 Startup 0 Hot Standby
Event Text
PLANT SHUTDOWN REQUIRED BY TECHNICAL SPECIFICATIONS

The following information was provided by the licensee via email:

"At 0507 EST on November 24, 2026, Millstone Unit 3 commenced a reactor shutdown and cooldown to mode 4 to comply with technical specification limiting condition for operation (LCO) 3.5.2 'emergency core cooling systems' for subsystems greater than 350 degrees Fahrenheit.

"The 'B' residual heat removal pump could not be restored within the 72 hours allowed LCO time requiring a technical specification shutdown.

"This event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(i)."

The NRC Resident Inspector was notified.