Event Notification Report for November 24, 2026

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/23/2026 - 11/24/2026

EVENT NUMBERS
58455585475853858539

Part 21
Event Number: 58455
Rep Org: Curtiss Wright Flow Control Co.
Licensee:
Region: 3
City: Cincinnati   State: OH
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Mark Papke
HQ OPS Officer: Robert A. Thompson
Notification Date: 09/18/2026
Notification Time: 10:22 [ET]
Event Date: 07/20/2026
Event Time: 00:00 [EDT]
Last Update Date: 11/23/2026
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
R3 Reactors Group (EMAIL)
Part 21/50.55 Reactors, - (EMAIL)
R2 Reactors Group (EMAIL)
Event Text
EN Revision Imported Date: 11/24/2026

EN Revision Text: PART 21 - RELAY CONTACTS SLOW TO CHANGE STATE

The following is a summary of information provided by the vendor via email:

In early July 2026 HB Robinson identified the relay contacts of a single Tyco relay would not properly actuate. Bench testing by Robinson indicated greater than 1 megaohm across relay contacts when the relay coil was energized and based on those results Robinson concluded that the expected contact transition was not occurring. Robinson returned the relay to Curtiss-Wright.

Curtiss-Wright testing found that the contacts did transition when the relay actuated but observed that a noticeable time delay was identified in the transition of the normally open contacts. Lag times ranged from 479 to 1,500 milliseconds. The relay was returned to Tyco for further evaluation to determine whether the measured response time represents acceptable product performance or is indicative of an abnormal condition or degradation within the relay. This evaluation is still ongoing, however Curtiss-Wright intends to have the final evaluation and report completed by November 17, 2026.

Affected plant: HB Robinson

Tyco part number: E7012PB004, S/N 24240332
Curtiss-Wright tag number: CJ1900501 S/N: 02

* * * UPDATE ON 11/23/2026 AT 1058 EST FROM MARK PAPKE TO JOSUE RAMIREZ * * *

The following information was provided by the vendor via email:

"[Tyco Electronics (TE)] Connectivity's evaluation determined that the barrel spring adjustment screw was not fully seated/torqued. The barrel spring adjustment was found in the fully relaxed position, which explains delay in contact transfer and/or failure to transfer. Contact transfer relies on the snap action of the lever arm/barrel spring in both normally open and normally closed directions. During engineering evaluation, the retainer clip, used to adjust the barrel spring, was found fully open allowing maximum extension of the barrel spring. The screw used to secure the retainer clip was fully thread, head flat against the retainer, but was not fully torqued. Since the screw was not fully torqued, it allowed the retaining clip to slide into the fully open position over time and use.
"TE Connectivity determined that this is not a systemic failure and has implemented a secondary torque verification following completion of terminal block scaling. Verification will be performed over a 3-month period or over a certain number of runs, depending on demand. By adding a secondary torque verification following completion of terminal block scaling, this will ensure that all screws have been torqued before assembly of the relay. Curtiss Wright agrees with this assessment.
"Since 2011 Curtiss Wright has supplied PN: E7012PB004 36 times to 6 different customers with no other reports of this defect."

Affected Customers: HB Robinson, McGuire, Oconee, Fermi, PSEG Nuclear (Hope Creek, Salem), and Enhanced Automation.


Notified R1 Reactors Group, R2 Reactors Group, R3 Reactors Group, and Part 21 group (Email).

Curtiss-Wright responsible manager
Mark Papke
QA Manager
Curtiss-Wright
4500 East Tech Drive
Cincinnati, OH 45245


Power Reactor
Event Number: 58547
Facility: Ginna
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: Sean Gillen
HQ OPS Officer: Robert A. Thompson
Notification Date: 11/22/2026
Notification Time: 10:07 [ET]
Event Date: 11/22/2026
Event Time: 09:22 [EST]
Last Update Date: 11/22/2026
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
R1 Reactor Events, (EMAIL)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY

The following information was provided by the licensee via phone and email:

"At 0922 EST on 11/22/2026, it was determined that a non-licensed supervisor failed a test specified by the fitness for duty testing program. The individual's authorization for site access has been terminated at all Constellation facilities.

"The NRC Resident Inspector has been notified."


Hospital
Event Number: 58538
Rep Org: Veterans Health Administration
Licensee: US department of Veteran affairs
Region: 3
City: Little Rock   State: AR
County:
License #: 03-23853-01VA
Agreement: N
Docket:
NRC Notified By: Kim Wiebeck
HQ OPS Officer: Philip Alier
Notification Date: 11/17/2026
Notification Time: 10:11 [ET]
Event Date: 11/16/2026
Event Time: 08:30 [CST]
Last Update Date: 11/17/2026
Emergency Class: Non Emergency
10 CFR Section:
35.3045(a)(1)(i) - Dose <> Prescribed Dosage
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
EDWARD, RHEX (NMSS R3)
Event Text
MEDICAL EVENT

The following information was provided by the Veterans Health Administration (VHA) via phone and email:

"Central Arkansas Veterans Healthcare System, Little Rock, Arkansas, which holds VHA Permit Number 03-01082-01 under the VA Master Materials License (03-23853-01VA), reported discovery of a medical event to the National Health Physics Program (NHPP) at approximately 1500 CST on November 16, 2026.

"A therapeutic administration of yttrium-90 (Y-90) microspheres (TheraSphere) to segment 8 of the right lobe of a patient's liver was performed at approximately 0830 CST on November 16, 2026. Subsequent measurements and calculations indicated that the patient received approximately 278 Gy, representing 56 percent of the prescribed dose of 500 Gy. The total activity required at administration to deliver 500 Gy was 1.09 GBq (29.5 mCi); the administered activity was estimated to be 0.57 GBq (15.4 mCi). A causal analysis of the medical event is being conducted by the medical center.

''The patient and the referring physician have been notified. At this time, short term harm to the patient is not expected. NHPP plans to perform a reactive inspection to assess causes and regulatory compliance. NHPP will follow up with a written report in accordance with NRC requirements in 10 CFR 35.3045."

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Agreement State
Event Number: 58539
Rep Org: Ohio Department of Health
Licensee: University of Cincinnati Medical
Region: 3
City: Cincinnati   State: OH
County:
License #: 02110310001
Agreement: Y
Docket:
NRC Notified By: Joshua Wagner
HQ OPS Officer: Adam Conklin
Notification Date: 11/17/2026
Notification Time: 14:41 [ET]
Event Date: 11/17/2026
Event Time: 00:00 [EST]
Last Update Date: 11/17/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSC (Canada), (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST SOURCES

The following is a summary of information provided by the Ohio Department of Health, Bureau of Environmental Health and Radiation Protection (ODH) via email:

The licensee in Ohio notified ODH that they did not receive two packages of I-125 seeds (133 mCi/4.921 GBq total). The common carrier had reported the packages delivered, potentially resulting in lost/stolen licensed radioactive material. ODH notified the shipper (IsoAid, Florida license 3196-1), Florida's radiation control program, and the NRC. The licensee never received or took possession of the shipped material, and they appear to be lost in transit. ODH will continue to investigate and provide updates on whether the material is found or delivered as intended.

Ohio Item Number: OH260009

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf