Skip to main content

Event Notification Report for November 05, 2026

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/04/2026 - 11/05/2026

EVENT NUMBERS
58508585095851758520

Agreement State
Event Number: 58508
Rep Org: Equistar Chemicals, LP
Licensee: Equistar Chemicals, LP
Region: 4
City: Westlake   State: LA
County:
License #: LA-2663-L01, Amendment: 41
Agreement: Y
Docket:
NRC Notified By: James Pate
HQ OPS Officer: Jon Lilliendahl
Notification Date: 10/28/2026
Notification Time: 14:20 [ET]
Event Date: 10/27/2026
Event Time: 15:10 [CDT]
Last Update Date: 10/28/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK SHUTTERS

The following is a summary of information provided by the Louisiana Department of Environmental Quality (LDEQ) via email:

On October 27, 2026, Equistar Chemicals, LP, contacted LDEQ concerning stuck shutters on four different fixed gauges. The shutters were determined to be stuck in the open position on October 27, 2026. The licensee will contact a third party, to determine the appropriate solution to correct this situation.

Gauge information:
1) One Ohmart Model Number SH-100, serial number 60828, 100 mCi Cs-137 source. Installed in 1985.
2) Two Ohmart Model Number SHD-45, each with 300 mCi sources.
3) One Ohmart Model Number SH-F, serial number M7122, 250 mCi Cs-137 source.

Louisiana incident number: LA20260013


Non-Agreement State
Event Number: 58509
Rep Org: US Army
Licensee: US Army Aviation and Missile Command
Region: 1
City: Salado   State: TX
County:
License #: 01-00126-22
Agreement: N
Docket:
NRC Notified By: Natalie Lonsberry
HQ OPS Officer: Jon Lilliendahl
Notification Date: 10/28/2026
Notification Time: 18:00 [ET]
Event Date: 08/12/2026
Event Time: 13:35 [CDT]
Last Update Date: 10/28/2026
Emergency Class: Non Emergency
10 CFR Section:
20.2201(a)(1)(ii) - Lost/Stolen LNM>10x
Person (Organization):
Katanic, Janine (NMSS R4)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSNS (Mexico), - (EMAIL)
Ford, Monica (NMSS R1)
Event Text
LOST SOURCES

The following information was provided by the licensee via phone:

On August 12, 2026, at 1335 CDT, an Army helicopter crashed in a field near Salado, TX. The crash caused extensive damage to the helicopter and a large grass fire. A crash investigation team has been recovering the helicopter remains over the last two months.

On October 27, 2026, at approximately 1015 CDT, the radiation safety officer was notified that two foil sources on the helicopter were not recovered and believed to have been incinerated.

The investigation is ongoing. A third party has been contracted to remediate the site.

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Power Reactor
Event Number: 58517
Facility: Arkansas Nuclear
Region: 4     State: AR
Unit: [2] [] []
RX Type: [1] B&W-L-LP,[2] CE
NRC Notified By: Stephen Feemster
HQ OPS Officer: Adam Koziol
Notification Date: 11/03/2026
Notification Time: 13:08 [ET]
Event Date: 11/03/2026
Event Time: 08:38 [CST]
Last Update Date: 11/03/2026
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Dixon, John (R4 DRPBC)
R4 Reactor Events (Email)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 100 Power Operation 0 Hot Standby
Event Text
AUTOMATIC REACTOR TRIP

The following information was provided by the licensee via phone and email:

"On November 3, 2026, at 0838 CST, Arkansas Nuclear One, Unit 2 experienced an automatic reactor trip from 100 percent power due to exceeding the departure from nucleate boiling ratio on reactor protection system (RPS) channels 1 and 2 due to the loss of all reactor coolant pump (RCPs). Emergency feedwater (EFW) actuated automatically due to low water level in the 'A' and 'B' steam generators. EFW responded as designed to feed both steam generators automatically.

"The loss of all RCPs was caused by non-vital 6900-volt buses '2H1' and '2H2' de-energizing. This resulted in a loss of reactor coolant system forced circulation and a loss of main condenser vacuum.

"Both emergency diesel generators (EDGs) automatically started due to the slow transfer of on-site electrical power to offsite power via the startup '3' transformer, but the EDGs did not automatically tie to their respective vital 4160-volt buses. '2A-1' and '2A-2' non-vital buses are supplied from offsite power as designed. The '2A-3' and '2A-4' vital 4160-volt buses remained energized from offsite power via '2A-1' and '2A-2' respectively.

"During the transient, service water pump '2P-4A' automatically tripped. Service water pump '2P-4B' was manually started to restore loop 1 service water to service.

"All control element assemblies fully inserted upon the trip. Unit 2 is currently stable in mode 3 (Hot Standby) maintaining pressure and temperature via emergency feedwater and secondary system steaming to atmosphere via the atmospheric dump valves.

"There are no indications of a radiological release or impact to the health and safety of the public or plant personnel as a result of this event. This event occurred immediately following a lightning strike near the station.

"This report satisfies the reporting criteria of both 10 CFR 50.72(b)(2)(iv)(B) for the RPS actuation and 10 CFR 50.72(b)(3)(iv)(A) for the valid RPS, EFW system, and EDG actuations.

"The NRC Senior Resident Inspector has been notified. Unit 1 was not affected."



Independent Spent Fuel Storage Installation
Event Number: 58520
Rep Org: San Onofre
Licensee: Southern California Edison Company
Region: 4
City: San Clemente   State: CA
County: San Diego
License #: GL
Agreement: Y
Docket: 72-41
NRC Notified By: Rob Doeing
HQ OPS Officer: Josue Ramirez
Notification Date: 11/04/2026
Notification Time: 14:53 [ET]
Event Date: 11/04/2026
Event Time: 09:30 [PST]
Last Update Date: 11/04/2026
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(xi) - Offsite Notification
Person (Organization):
NMSS_Events_Notification, (EMAIL)
Anderson, Stephanie (R4BC)
Event Text
OFFSITE NOTIFICATION

The following information was provided by the licensee via phone and email:

"On November 3, 2026, water from the unit 3 sump was being pumped to the oil waste separator (OWS) at approximately 1015 [PST], a clamp on the hose coupling failed, causing the coupling to separate. Water was released into the environment along the northwest side of the MHF [Material Handling Facility] tent. Upon discovery of the leak, immediate actions were taken to stop the pumping operation.

"On November 4, 2026, at 0930 [PST], San Onofre Nuclear Generating Station (SONGS) notified the San Diego Regional Water Quality Control Board of unplanned discharge associated with the SONGS NPDES [National Pollutant Discharge Elimination System] permit. This report is submitted in accordance with 50.72(b)(2)(xi) for contact with an offsite agency. In addition, this report is part of the voluntary communication protocol described in NEI 07-07 for the groundwater protection initiative.

"Approximately 900 gallons were released, samples were taken and the results are as follows: pH 11.6; total suspended solids 68.4 ppm; Tritium 8.36E-6 microCi/ml (8,360 pCi/l); gamma not detected.

"Based on currently available information, [Southern California Edison] SCE believes there is no adverse impact to ground water and ocean water quality."