Event Notification Report for April 28, 2025
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
04/27/2025 - 04/28/2025
Agreement State
Event Number: 57671
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: Northwestern Memorial Hospital
Region: 3
City: Chicago State: IL
County:
License #: IL-01037-02
Agreement: Y
Docket:
NRC Notified By: Robin Muzzalupo
HQ OPS Officer: Josue Ramirez
Licensee: Northwestern Memorial Hospital
Region: 3
City: Chicago State: IL
County:
License #: IL-01037-02
Agreement: Y
Docket:
NRC Notified By: Robin Muzzalupo
HQ OPS Officer: Josue Ramirez
Notification Date: 04/18/2025
Notification Time: 10:25 [ET]
Event Date: 04/15/2025
Event Time: 00:00 [CDT]
Last Update Date: 04/18/2025
Notification Time: 10:25 [ET]
Event Date: 04/15/2025
Event Time: 00:00 [CDT]
Last Update Date: 04/18/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - MEDICAL EVENT
The following information was provided by the Illinois Emergency Management Agency (the Agency) via phone and email:
"The radiation safety officer for Northwestern Memorial Healthcare contacted the Agency on 4/17/2025 to report a medical underdose. Initial information indicated an underdosing of Y-90 TheraSpheres of 54 percent. The patient reportedly tolerated the procedure well and no further treatment is scheduled. The administering physician reported an issue with vasoconstriction of the target artery. The licensee confirmed that the patient and referring physician were notified. The licensee did not meet reporting requirements, which will be addressed during a reactive inspection to be conducted on 4/21/2025."
The intended activity was 17.03 mCi (630.11 MBq) and the administered activity was 7.84 mCi (290.08 MBq).
Illinois Reference Number: IL250016
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The following information was provided by the Illinois Emergency Management Agency (the Agency) via phone and email:
"The radiation safety officer for Northwestern Memorial Healthcare contacted the Agency on 4/17/2025 to report a medical underdose. Initial information indicated an underdosing of Y-90 TheraSpheres of 54 percent. The patient reportedly tolerated the procedure well and no further treatment is scheduled. The administering physician reported an issue with vasoconstriction of the target artery. The licensee confirmed that the patient and referring physician were notified. The licensee did not meet reporting requirements, which will be addressed during a reactive inspection to be conducted on 4/21/2025."
The intended activity was 17.03 mCi (630.11 MBq) and the administered activity was 7.84 mCi (290.08 MBq).
Illinois Reference Number: IL250016
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Agreement State
Event Number: 57672
Rep Org: Illinois Emergency Mgmt. Agency
Licensee: Isomedix Operations, Inc.
Region: 3
City: Libertyville State: IL
County:
License #: IL-01123-02
Agreement: Y
Docket:
NRC Notified By: Robin Muzzalupo
HQ OPS Officer: Kerby Scales
Licensee: Isomedix Operations, Inc.
Region: 3
City: Libertyville State: IL
County:
License #: IL-01123-02
Agreement: Y
Docket:
NRC Notified By: Robin Muzzalupo
HQ OPS Officer: Kerby Scales
Notification Date: 04/18/2025
Notification Time: 13:29 [ET]
Event Date: 04/17/2025
Event Time: 00:00 [CDT]
Last Update Date: 04/18/2025
Notification Time: 13:29 [ET]
Event Date: 04/17/2025
Event Time: 00:00 [CDT]
Last Update Date: 04/18/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Nguyen, April (R3DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - FAILURE OF EXIT PORTAL MONITOR
The following report was received by the Illinois Emergency Management Agency (the Agency) via phone and email:
"The corporate radiation safety officer for Isomedix Operations, Inc. (IL-01123-02) contacted the Agency on 4/18/2025 to report that during routine monthly testing of the exit portal monitor conducted on 4/17/2025, on the Co-60 pool irradiator (irradiator 192), the monitor failed to respond to radiation. The issue was immediately identified as corrosion on the cable-to-probe connection and was subsequently repaired, tested, and found to be functional. There was no report of exposure to personnel or loss of control. The licensee reported the failure within 24 hours as required by 346.830(a) and will submit a written report within 30 days as required."
Illinois Item Number: IL250017
The following report was received by the Illinois Emergency Management Agency (the Agency) via phone and email:
"The corporate radiation safety officer for Isomedix Operations, Inc. (IL-01123-02) contacted the Agency on 4/18/2025 to report that during routine monthly testing of the exit portal monitor conducted on 4/17/2025, on the Co-60 pool irradiator (irradiator 192), the monitor failed to respond to radiation. The issue was immediately identified as corrosion on the cable-to-probe connection and was subsequently repaired, tested, and found to be functional. There was no report of exposure to personnel or loss of control. The licensee reported the failure within 24 hours as required by 346.830(a) and will submit a written report within 30 days as required."
Illinois Item Number: IL250017
Agreement State
Event Number: 57674
Rep Org: Arkansas Department of Health
Licensee: IQS Inspection LLC
Region: 4
City: North Little Rock State: AR
County:
License #: ARK-0773-03320
Agreement: Y
Docket:
NRC Notified By: David Eichenberger
HQ OPS Officer: Kerby Scales
Licensee: IQS Inspection LLC
Region: 4
City: North Little Rock State: AR
County:
License #: ARK-0773-03320
Agreement: Y
Docket:
NRC Notified By: David Eichenberger
HQ OPS Officer: Kerby Scales
Notification Date: 04/21/2025
Notification Time: 14:52 [ET]
Event Date: 04/16/2025
Event Time: 17:30 [CDT]
Last Update Date: 04/21/2025
Notification Time: 14:52 [ET]
Event Date: 04/16/2025
Event Time: 17:30 [CDT]
Last Update Date: 04/21/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Rollins, Jesse (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Rollins, Jesse (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
AGREEMENT STATE REPORT - STUCK SOURCE
The following is a summary of information provided by the Arkansas Department of Health via email:
On Thursday, April 17, 2025, at 1309 CDT, the licensee submitted a notification that on Wednesday, April 16, 2025, at 1730 CDT, they had experienced a radiography source failure to retract. The radiation safety officer (RSO) was notified. They arrived onsite at 1930 CDT with retrieval tools and shielding and was able to retract the source into the camera by 2330 CDT. The location was in an isolated area of the Union Pacific rail yard with concrete abutments that afforded shielding of the source. Exposures were limited to 134 millirem to the RSO, 36 millirem to the radiographer, and 11 millirem to the trainee. There was no exposure to the public.
The exposure device is a SPEC 150, serial number 2240, with a SPEC model G-60 source, serial number FL1805, with 33 curies of Ir-192.
The cause was determined to be a kink or crimp in the guide tubing preventing the source from retracting. The investigation is ongoing, and reporting will proceed in accordance with SA-300.
Arkansas Event Number: AR-2025-002
The following is a summary of information provided by the Arkansas Department of Health via email:
On Thursday, April 17, 2025, at 1309 CDT, the licensee submitted a notification that on Wednesday, April 16, 2025, at 1730 CDT, they had experienced a radiography source failure to retract. The radiation safety officer (RSO) was notified. They arrived onsite at 1930 CDT with retrieval tools and shielding and was able to retract the source into the camera by 2330 CDT. The location was in an isolated area of the Union Pacific rail yard with concrete abutments that afforded shielding of the source. Exposures were limited to 134 millirem to the RSO, 36 millirem to the radiographer, and 11 millirem to the trainee. There was no exposure to the public.
The exposure device is a SPEC 150, serial number 2240, with a SPEC model G-60 source, serial number FL1805, with 33 curies of Ir-192.
The cause was determined to be a kink or crimp in the guide tubing preventing the source from retracting. The investigation is ongoing, and reporting will proceed in accordance with SA-300.
Arkansas Event Number: AR-2025-002
Part 21
Event Number: 57680
Rep Org: Asco Valve
Licensee:
Region: 2
City: Aiken State: SC
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Bryan Causey
HQ OPS Officer: Josue Ramirez
Licensee:
Region: 2
City: Aiken State: SC
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Bryan Causey
HQ OPS Officer: Josue Ramirez
Notification Date: 04/24/2025
Notification Time: 15:56 [ET]
Event Date: 04/24/2025
Event Time: 00:00 [EDT]
Last Update Date: 04/24/2025
Notification Time: 15:56 [ET]
Event Date: 04/24/2025
Event Time: 00:00 [EDT]
Last Update Date: 04/24/2025
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
Pearson, Laura (R2DO)
Part 21/50.55 Reactors, - (EMAIL)
Part 21 Materials, - (EMAIL)
Pearson, Laura (R2DO)
Part 21/50.55 Reactors, - (EMAIL)
Part 21 Materials, - (EMAIL)
PART 21 REPORT - SOLENOID VALVE FAILS TO OPERATE AFTER EXTENDED DE-ENERGIZATION
The following is a summary of the information provided by ASCO via email:
This report relates to the failure of a single air-operated valve identified by Dominion Energy at North Anna due to failure of the associated solenoid valve. The solenoid valve periodically failed to reposition, or only partially repositioned, after periods of extended de-energization.
As part of testing, the ASCO NP8321 solenoid valve series and all ASCO NP-series solenoid valves were qualified to sit in a normally energized position and were not tested for extended periods of de-energization. The U-cup seal was tested and ASCO determined that this U-cup seal experienced performance limitations at low air operating pressures (below 40 psi) and the valve did not shift completely to an energized state.
An alternative valve (NP8300) is recommended by ASCO for this customer application. In the interim, ASCO recommends increasing the inlet air pressure to the valve to at least 80 psi not to exceed the maximum 150 psi to conservatively ensure proper operation of the NP8321 series valve in a de-energized state.
ASCO concludes based on design and known operating experience that only the NP8321 model valve exhibits this condition.
ASCO does not have adequate knowledge of the actual installation and operating condition of this valve to determine whether this condition would create a `substantial' safety hazard as defined in 10 CFR 21.3. The report is intended to provide investigation results and recommendations. Each end user needs to perform their own evaluation based on the information provided in this notification.
Bryan Causey
Quality Engineer
Bryan.Causey@Emerson.com
The only plant known to be affected at the time of the report is North Anna.
The following is a summary of the information provided by ASCO via email:
This report relates to the failure of a single air-operated valve identified by Dominion Energy at North Anna due to failure of the associated solenoid valve. The solenoid valve periodically failed to reposition, or only partially repositioned, after periods of extended de-energization.
As part of testing, the ASCO NP8321 solenoid valve series and all ASCO NP-series solenoid valves were qualified to sit in a normally energized position and were not tested for extended periods of de-energization. The U-cup seal was tested and ASCO determined that this U-cup seal experienced performance limitations at low air operating pressures (below 40 psi) and the valve did not shift completely to an energized state.
An alternative valve (NP8300) is recommended by ASCO for this customer application. In the interim, ASCO recommends increasing the inlet air pressure to the valve to at least 80 psi not to exceed the maximum 150 psi to conservatively ensure proper operation of the NP8321 series valve in a de-energized state.
ASCO concludes based on design and known operating experience that only the NP8321 model valve exhibits this condition.
ASCO does not have adequate knowledge of the actual installation and operating condition of this valve to determine whether this condition would create a `substantial' safety hazard as defined in 10 CFR 21.3. The report is intended to provide investigation results and recommendations. Each end user needs to perform their own evaluation based on the information provided in this notification.
Bryan Causey
Quality Engineer
Bryan.Causey@Emerson.com
The only plant known to be affected at the time of the report is North Anna.
Power Reactor
Event Number: 57681
Facility: Farley
Region: 2 State: AL
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Chad Myers
HQ OPS Officer: Karen Cotton-Gross
Region: 2 State: AL
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Chad Myers
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 04/25/2025
Notification Time: 14:51 [ET]
Event Date: 04/24/2025
Event Time: 23:21 [CDT]
Last Update Date: 04/25/2025
Notification Time: 14:51 [ET]
Event Date: 04/24/2025
Event Time: 23:21 [CDT]
Last Update Date: 04/25/2025
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Pearson, Laura (R2DO)
FFD Group, (EMAIL)
Pearson, Laura (R2DO)
FFD Group, (EMAIL)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | 100 | ||
| 2 | N | N | 0 | 0 |
FITNESS FOR DUTY - ALCOHOL CONTAINER FOUND IN PROTECTED AREA
The following information was provided by the licensee via phone and email:
"On April 24, 2025, at approximately 2321 CDT, an empty 100 mL alcohol bottle was found in the protected area by a contract employee. Site security was notified and took possession of the bottle which was removed from the protected area.
"The NRC Resident Inspector was notified."
The following information was provided by the licensee via phone and email:
"On April 24, 2025, at approximately 2321 CDT, an empty 100 mL alcohol bottle was found in the protected area by a contract employee. Site security was notified and took possession of the bottle which was removed from the protected area.
"The NRC Resident Inspector was notified."
Agreement State
Event Number: 57675
Rep Org: California Radiation Control Prgm
Licensee: Ambessaw Consulting
Region: 4
City: Los Angeles State: CA
County:
License #: 8357-19
Agreement: Y
Docket:
NRC Notified By: Donald Oesterle
HQ OPS Officer: Sam Colvard
Licensee: Ambessaw Consulting
Region: 4
City: Los Angeles State: CA
County:
License #: 8357-19
Agreement: Y
Docket:
NRC Notified By: Donald Oesterle
HQ OPS Officer: Sam Colvard
Notification Date: 04/21/2025
Notification Time: 23:59 [ET]
Event Date: 04/20/2025
Event Time: 22:40 [PDT]
Last Update Date: 04/22/2025
Notification Time: 23:59 [ET]
Event Date: 04/20/2025
Event Time: 22:40 [PDT]
Last Update Date: 04/22/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Rollins, Jesse (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSNS (Mexico) (EMAIL)
Rollins, Jesse (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL) (EMAIL)
CNSNS (Mexico) (EMAIL)
AGREEMENT STATE REPORT - LOST OR STOLEN DENSITY GAUGE
The following report was received by the California Radiation Control Program (the Agency) via email:
"On April 21, 2025, the licensee's radiation safety officer (RSO) contacted the Agency to report the theft of a Troxler 3440 moisture density gauge, serial number 31320. The theft occurred on April 20, 2025, at 2240 PDT at a jobsite in Los Angeles, California. The Los Angeles Police Department was contacted, and a police report was filed. The Troxler gauge contains an 8 mCi cesium-137 sealed source and a 40 mCi americium-241/Be sealed source. The investigation is ongoing."
California 5010 Number: 042125
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following report was received by the California Radiation Control Program (the Agency) via email:
"On April 21, 2025, the licensee's radiation safety officer (RSO) contacted the Agency to report the theft of a Troxler 3440 moisture density gauge, serial number 31320. The theft occurred on April 20, 2025, at 2240 PDT at a jobsite in Los Angeles, California. The Los Angeles Police Department was contacted, and a police report was filed. The Troxler gauge contains an 8 mCi cesium-137 sealed source and a 40 mCi americium-241/Be sealed source. The investigation is ongoing."
California 5010 Number: 042125
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
Power Reactor
Event Number: 57683
Facility: Cooper
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Bailey Giles
HQ OPS Officer: Troy Johnson
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Bailey Giles
HQ OPS Officer: Troy Johnson
Notification Date: 04/28/2025
Notification Time: 14:00 [ET]
Event Date: 04/28/2025
Event Time: 10:26 [CDT]
Last Update Date: 04/28/2025
Notification Time: 14:00 [ET]
Event Date: 04/28/2025
Event Time: 10:26 [CDT]
Last Update Date: 04/28/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(xiii) - Loss Comm/Asmt/Response
10 CFR Section:
50.72(b)(3)(xiii) - Loss Comm/Asmt/Response
Person (Organization):
Agrawal, Ami (R4DO)
Agrawal, Ami (R4DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | 100 |
LOSS OF OFF-SITE COMMUNICATION
The following information was provided by the licensee via phone and email:
"On 4/28/2025 at 1026 CDT, the National Weather Service notified Cooper Nuclear Station that the Shubert tower is disabled due to planned maintenance. The planned maintenance will continue from Monday, 4/28/2025 to Wednesday, 4/30/2025. This constitutes a loss of the primary public prompt notification system for greater than 24 hours. The Shubert tower transmitter activates the emergency alert system (EAS)/tone alert radios used for public notification. The backup notification system has been verified to be available for use, if needed, throughout this period. This condition is reportable under 10 CFR 50.72(b)(3)(xiii) as a major loss of the public prompt notification system capability since the backup alert methods do not meet the primary systems design objective.
"The NRC Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The National Weather Service notified the local authorities that the Shubert tower is disabled due to planned maintenance.
The following information was provided by the licensee via phone and email:
"On 4/28/2025 at 1026 CDT, the National Weather Service notified Cooper Nuclear Station that the Shubert tower is disabled due to planned maintenance. The planned maintenance will continue from Monday, 4/28/2025 to Wednesday, 4/30/2025. This constitutes a loss of the primary public prompt notification system for greater than 24 hours. The Shubert tower transmitter activates the emergency alert system (EAS)/tone alert radios used for public notification. The backup notification system has been verified to be available for use, if needed, throughout this period. This condition is reportable under 10 CFR 50.72(b)(3)(xiii) as a major loss of the public prompt notification system capability since the backup alert methods do not meet the primary systems design objective.
"The NRC Resident Inspector has been notified."
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The National Weather Service notified the local authorities that the Shubert tower is disabled due to planned maintenance.