The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Event Notification Report for March 19, 2025

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/18/2025 - 03/19/2025

EVENT NUMBERS
57598 57614 57615 57616
Agreement State
Event Number: 57598
Rep Org: WA Office of Radiation Protection
Licensee: Terra Associates Inc.
Region: 4
City: Redmond   State: WA
County:
License #: I0246
Agreement: Y
Docket:
NRC Notified By: Dane Blakinger
HQ OPS Officer: Kerby Scales
Notification Date: 03/11/2025
Notification Time: 16:32 [ET]
Event Date: 03/07/2025
Event Time: 14:30 [PST]
Last Update Date: 03/11/2025
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Warnick, Greg (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST/FOUND GAUGE

The following information was received from the Washington State Department of Health (the Department) via email:

"On March 7, 2025, at 1613 PDT, the Department was notified that a portable gauge (Troxler 3411-B) had fallen from a vehicle. This notification initially came from the Washington State Emergency Operations Officer of the Washington Military Department. The notification stated that the licensee had submitted a police report and was actively searching for the source.

"At 1633, the Department Emergency Response Duty Officer (ERDO) forwarded the notification to the Radioactive Materials Section Manager. At 1711, the Materials Section Manager contacted the licensee by phone to determine the scope of response necessary. The licensee informed the Department that the gauge was contained in a locked box and was believed to be lost or stolen. The licensee called back at 1716, informing the Department that the gauge had been found with the box locked, intact, and no signs of damage to the source contained within the shielded gauge. The gauge was found along the side of the road, in a ditch and away from any pedestrian traffic. No exposure is believed to have occurred to the public when considering the source was in a shielded position and inside of a locked Troxler class A container.

"The source was verified to be intact and sealed. Operational verifications of the gauge were performed, and the gauge is functioning normally. The gauge is in the possession of the licensee.

"A final report will be submitted to the NRC after the licensee has responded with corrective actions."

Washington Incident Number: WA-25-005


Power Reactor
Event Number: 57614
Facility: Prairie Island
Region: 3     State: MN
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: Timothy Thomas
HQ OPS Officer: Ernest West
Notification Date: 03/18/2025
Notification Time: 14:04 [ET]
Event Date: 03/18/2025
Event Time: 10:59 [CST]
Last Update Date: 03/18/2025
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Havertape, Joshua (R3DO)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 100
2 N Y 100 100
Event Text
FITNESS FOR DUTY

The following information was provided by the licensee via phone and email:

"At 1059 [CDT] on March 18, 2025, it was determined that a licensed operator failed a [random] test specified by the fitness-for-duty testing program. The individual's authorization for site access has been terminated.

"The NRC Resident Inspector has been notified."


Power Reactor
Event Number: 57615
Facility: Millstone
Region: 1     State: CT
Unit: [3] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: Kevin Woods
HQ OPS Officer: Ernest West
Notification Date: 03/18/2025
Notification Time: 16:59 [ET]
Event Date: 03/18/2025
Event Time: 10:26 [EST]
Last Update Date: 03/18/2025
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
50.72(b)(3)(v)(C) - Pot Uncntrl Rad Rel
Person (Organization):
Elkhiamy, Sarah (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 100
Event Text
SECONDARY CONTAINMENT BOUNDARY INOPERABLE

The following information was provided by the licensee via phone and fax:

"At 1026 [EDT] on March 18, 2025, it was discovered that the secondary containment boundary door was found fully open, rendering the secondary containment boundary inoperable, therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72 (b)(3)(v). The door was closed at 1029 on March 18, 2025, and the secondary containment boundary was declared operable.

"There is no impact on the health and safety of the public or plant personnel.

"The NRC Resident Inspector has been notified.

"There has been no impact to Unit 2 and Unit 3 continues to operate at 100 percent power."


Power Reactor
Event Number: 57616
Facility: Perry
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: Clifford G. Jones, Jr.
HQ OPS Officer: Bethany Cecere
Notification Date: 03/18/2025
Notification Time: 19:53 [ET]
Event Date: 03/18/2025
Event Time: 09:30 [EST]
Last Update Date: 03/18/2025
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Havertape, Joshua (R3DO)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 0 0
Event Text
FAILED FITNESS FOR DUTY TEST

The following information was provided by the licensee via phone and email:

"At 0930 EDT, March 18, 2025, it was determined that a contract supervisor failed a [random] test specified by the fitness-for-duty testing program. The individual's authorization for site access has been terminated.

"The NRC Resident Inspector has been notified."