Skip to main content

Event Notification Report for November 14, 2023

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/13/2023 - 11/14/2023

EVENT NUMBERS
568555685356852

Agreement State
Event Number: 56855
Rep Org: Texas Dept of State Health Services
Licensee: CMT Associates
Region: 4
City: Dallas   State: TX
County:
License #: L06945
Agreement: Y
Docket:
NRC Notified By: Art Tucker
HQ OPS Officer: Ernest West
Notification Date: 11/15/2023
Notification Time: 16:40 [ET]
Event Date: 11/14/2023
Event Time: 00:00 [CST]
Last Update Date: 11/15/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Vossmar, Patricia (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
CNSNS (Mexico) (EMAIL)
Event Text
AGREEMENT STATE - LOST TROXLER GAUGE

The following information was provided by the Texas Department of State Health Services (the Department) via phone and email:

"On November 15, 2023, the Department was notified by the licensee that a Troxler model 3440 moisture/density gauge had been lost. The gauge contains one 8 millicurie Cs-137 source and one 40 millicurie Am-241 source.

"The radiation safety officer (RSO) stated that on November 14, 2023, a licensee technician was performing work at a temporary job site where testing was being performed periodically. While sitting in their truck with the gauge on the tailgate of the truck, the technician realized they needed to go to a second job site about 20 minutes from where he was. When they reached the second job site, the technician realized they had left the gauge on the tailgate.

"The technician notified the licensee's RSO and the licensee conducted multiple searches for the gauge but did not locate the gauge. The RSO was advised to contact local law enforcement about the event. The RSO was advised to check local pawn shops and internet sites such as eBay and Craig's List to watch for the gauge. The RSO does not believe the gauge possesses an exposure risk to any individual. Additional information will be provided as it is received in accordance with SA-300."

Texas Incident Number: 10066

NMED Number: TX230052

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 56853
Rep Org: Florida Bureau of Radiation Control
Licensee: Moffitt Cancer Center
Region: 1
City: Tampa   State: FL
County:
License #: 1739-1
Agreement: Y
Docket:
NRC Notified By: Paul Norman
HQ OPS Officer: Ernest West
Notification Date: 11/14/2023
Notification Time: 16:54 [ET]
Event Date: 11/14/2023
Event Time: 12:11 [EST]
Last Update Date: 11/14/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Defrancisco, Anne (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
DOSE GREATER THAN PRESCRIBED

The following information was provided by the Florida Department of Health via email:

"On 11/14/2023, a patient arrived in the nuclear medicine department for administration of their fourth cycle of Lutathera, a Lu-177 labeled radiopharmaceutical. The standard prescription of Lutathera for patients is 200 mCi in accordance with manufacturer's instructions for use and industry standard. The technologist assayed the vial and went through pre-administration procedures including a pre-treatment time out. 202 mCi of Lutathera was administered via IV in the right upper forearm over the course of thirty minutes. Start time of 1211 [EST] with an end time of 1241.

"Upon completion of the procedure, the technologist noticed that the patient had been prescribed a reduced activity of 150 mCi as opposed to the standard prescription of 200 mCi. Realizing this was a medical event, the technologist notified the radiation safety officer (RSO) at approximately 1330. The technologist also informed the nuclear medicine department supervisor. The RSO proceeded to inform the Authorized User (AU)/prescribing physician.

"The AU spoke with the patient explaining that the activity administered exceeded the prescribed amount. The physician explained that he did not expect any adverse effects from the higher than prescribed activity as the patient had received the standard activity of 200 mCi. The reduced activity of 150 mCi had been decided by the prescribing physician due to borderline renal function and the patient had tolerated all previous three administrations. Since the patient's renal function was not affected by the three previous administrations, the prescribing physician explained that the patient could have received the 200 mCi. The patient did not express concern upon being informed of this event.

"The AU also informed the referring physician.

"An initial report was made to [Florida] via telephone at 1529 in accordance with 64E-5.345(4)(a)."

Florida Incident Number: FL23-164

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Power Reactor
Event Number: 56852
Facility: Farley
Region: 2     State: AL
Unit: [2] [] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: Roosevelt Scott
HQ OPS Officer: Ernest West
Notification Date: 11/14/2023
Notification Time: 14:36 [ET]
Event Date: 11/14/2023
Event Time: 10:41 [CST]
Last Update Date: 11/14/2023
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical 50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Miller, Mark (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 10 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP

The following information was provided by the licensee via phone and email:

"At 1041 CST on 11/14/23 with Farley Unit 2 in Mode 1 at 10 percent power, the reactor was manually tripped due to rising steam generator levels. The trip was not complex, with all systems responding normally post-trip.

"Operations responded and stabilized the plant. Auxiliary feedwater (AFW) was manually initiated in accordance with plant procedures and is feeding the steam generators. Heat removal is being provided via the atmospheric relief valves. Unit 1 is not affected.

"Due to the reactor protection system actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B). This event is also being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(iv)(A) as an event that results in a valid actuation of the auxiliary feedwater system.

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."


The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:

All rods fully inserted. The licensee attempted to take manual control of the feedwater control valves to lower steam generator level but, due to reaching a steam generator level that requires a manual trip, the licensee manually tripped the reactor.