Skip to main content

Event Notification Report for January 06, 2023

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/05/2023 - 01/06/2023

EVENT NUMBERS
5630356305

Agreement State
Event Number: 56303
Rep Org: Florida Bureau of Radiation Control
Licensee: Professional Service Industries
Region: 1
City: Tallahassee   State: FL
County:
License #: 0022-17
Agreement: Y
Docket:
NRC Notified By: Mark Seidensticker
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 01/06/2023
Notification Time: 12:27 [ET]
Event Date: 01/06/2023
Event Time: 10:05 [EST]
Last Update Date: 01/06/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Deboer, Joseph (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - DAMAGED TROXLER GAUGE

The following information was provided by the Florida Bureau of Radiation Control (BRC) via email:

"Professional Service Industries (PSI), Inc. called the BRC in Tallahassee to report a Troxler gauge [Troxler model 2440 (serial number (SL): 27404) containing Cs-137(SL: 750-1167) and Am-241:Be (SL:47-23791) sources] had been run over on a construction site in Winter Garden. BRC in Orlando was notified at 1005 EST. The Duty Officer in Orlando called PSI, who reported that the yellow gauge casing was broken, and the guide rod was also damaged. The source rod was reported to be in the fully retracted position. Reported survey readings onsite were normal for the Troxler gauge. An inspector from BRC, who was already enroute to the construction site, was notified and will conduct an investigation."

Florida Event Number: FL23-002


* * * UPDATE ON 01/06/2023 AT 1514 EST FROM FLORIDA BUREAU OF RADIATION CONTROL TO KAREN COTTON * * *
Source date of both isotopes 4/21/1997; initial activity for Cs137 was 8 mCi, serial number 750-1167; initial activity for Am241:Be was 40 mCi, serial number 47-23791. Contact dose rate is 18 mR/hr. Machinery was a tractor driven steam roller that backed over the gauge, with gauge going between the back tires. The rear axle area hit the gauge, not the tires or the steam roller cylinder. Gauge is being transported back to Troxler in the Orlando Metro area, in the original Type A transport case.

Notified R1DO (Deboer) and NMSS Events Notification via email


Agreement State
Event Number: 56305
Rep Org: Tennessee Div of Rad Health
Licensee: NYRSTAR
Region: 1
City: Gordonsville   State: TN
County:
License #: GL-449
Agreement: Y
Docket:
NRC Notified By: Andrew Holcomb
HQ OPS Officer: Ernest West
Notification Date: 01/10/2023
Notification Time: 14:32 [ET]
Event Date: 01/06/2023
Event Time: 00:00 [EST]
Last Update Date: 01/10/2023
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Jackson, Don (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - STUCK SHUTTER

The following information was provided by the Tennessee Division of Radiological Health via email:

"During a scheduled source disposal with a Berthold technician, a licensee staff member broke the handle off the gauge when trying to close the shutter. The technician took surveys to verify the shutter was stuck in the open position. The plan from the Berthold technician is to design lead plates to simulate a closed shutter for the device to be shipped offsite.

"Corrective actions or reports as well as additional information will be updated with an NMED report within 30 days."

Manufacturer: Ohmart/Vega
Model: SH-F1A-0
Model SN: 3368CN
Isotope: Cs-137, 5 mCi

State Event Report ID number: TN-23-001