Event Notification Report for March 10, 2022
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/09/2022 - 03/10/2022
Agreement State
Event Number: 55762
Rep Org: Colorado Dept of Health
Licensee: Avago Tech
Region: 4
City: Fort Collins State: CO
County:
License #: GL002495
Agreement: Y
Docket:
NRC Notified By: Kathryn Mote
HQ OPS Officer: Gerond George
Licensee: Avago Tech
Region: 4
City: Fort Collins State: CO
County:
License #: GL002495
Agreement: Y
Docket:
NRC Notified By: Kathryn Mote
HQ OPS Officer: Gerond George
Notification Date: 03/02/2022
Notification Time: 12:04 [ET]
Event Date: 03/02/2022
Event Time: 12:04 [MST]
Last Update Date: 03/02/2022
Notification Time: 12:04 [ET]
Event Date: 03/02/2022
Event Time: 12:04 [MST]
Last Update Date: 03/02/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Agrawal, Ami (R4)
NMSS_Events_Notification, (EMAIL)
ILTAB, (EMAIL)
Agrawal, Ami (R4)
NMSS_Events_Notification, (EMAIL)
ILTAB, (EMAIL)
EN Revision Imported Date: 3/10/2022
EN Revision Text: AGREEMENT STATE REPORT - LOST TRITIUM EXIT SIGNS
The following information was received via E-mail:
On 01/27/22, Avago Tech reported four tritium exit signs (2.3 Ci each) as lost during their final wrap up shipment for disposal.
NMED No.: CO220005
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf.
EN Revision Text: AGREEMENT STATE REPORT - LOST TRITIUM EXIT SIGNS
The following information was received via E-mail:
On 01/27/22, Avago Tech reported four tritium exit signs (2.3 Ci each) as lost during their final wrap up shipment for disposal.
NMED No.: CO220005
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf.
Agreement State
Event Number: 55763
Rep Org: Iowa Department of Public Health
Licensee: Arconic Davenport, LLC
Region: 3
City: Bettendoff State: IA
County:
License #: 0162182FG
Agreement: Y
Docket:
NRC Notified By: Dahlin Randal
HQ OPS Officer: Karen Cotton-Gross
Licensee: Arconic Davenport, LLC
Region: 3
City: Bettendoff State: IA
County:
License #: 0162182FG
Agreement: Y
Docket:
NRC Notified By: Dahlin Randal
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 03/03/2022
Notification Time: 09:57 [ET]
Event Date: 03/02/2022
Event Time: 00:00 [CST]
Last Update Date: 03/03/2022
Notification Time: 09:57 [ET]
Event Date: 03/02/2022
Event Time: 00:00 [CST]
Last Update Date: 03/03/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Feliz-Adorno, Nestor (R3)
NMSS_Events_Notification, (EMAIL)
Feliz-Adorno, Nestor (R3)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 3/11/2022
EN Revision Text: AGREEMENT STATE REPORT - STUCK SHUTTER GAUGE
The following information was provided by the Iowa Department of Public Health via email:
"A stuck shutter was discovered Wednesday, March 2nd on the B-gauge, shutter 1. Entry to the gauge house has been prohibited per protocol. Measurements indicate an increase dose rate relative to background at the south side adjacent to the gauge and shutter 1 position, with a maximum reading of 0.11 mR/hr. The licensee's service provider, SenTek, has been requested to perform emergency repair work. The B-Gauge was repaired last night around 1900 CST. The shutter failed to close due to the solenoid valve that opens and closes the shutter, which would not vent pressure. The failed solenoid valve was replaced by a new valve. The project to replace these gauges with x-ray technology is ongoing and on track to be replaced by first quarter, 2023."
"Source/Radioactive Material: SEALED SOURCE GAUGE
Manufacturer: Isotope Measuring Systems, Inc.
Model Number: NOT KNOWN IAEA Category: 3
Serial Number: 2332-2336L
Radionuclide: AM-241
Activity: 5 Ci (185 GBq)"
Iowa Event Number: IA220001
EN Revision Text: AGREEMENT STATE REPORT - STUCK SHUTTER GAUGE
The following information was provided by the Iowa Department of Public Health via email:
"A stuck shutter was discovered Wednesday, March 2nd on the B-gauge, shutter 1. Entry to the gauge house has been prohibited per protocol. Measurements indicate an increase dose rate relative to background at the south side adjacent to the gauge and shutter 1 position, with a maximum reading of 0.11 mR/hr. The licensee's service provider, SenTek, has been requested to perform emergency repair work. The B-Gauge was repaired last night around 1900 CST. The shutter failed to close due to the solenoid valve that opens and closes the shutter, which would not vent pressure. The failed solenoid valve was replaced by a new valve. The project to replace these gauges with x-ray technology is ongoing and on track to be replaced by first quarter, 2023."
"Source/Radioactive Material: SEALED SOURCE GAUGE
Manufacturer: Isotope Measuring Systems, Inc.
Model Number: NOT KNOWN IAEA Category: 3
Serial Number: 2332-2336L
Radionuclide: AM-241
Activity: 5 Ci (185 GBq)"
Iowa Event Number: IA220001
Power Reactor
Event Number: 55775
Facility: Davis Besse
Region: 3 State: OH
Unit: [1] [] []
RX Type: [1] B&W-R-LP
NRC Notified By: Robert Oesterle
HQ OPS Officer: Donald Norwood
Region: 3 State: OH
Unit: [1] [] []
RX Type: [1] B&W-R-LP
NRC Notified By: Robert Oesterle
HQ OPS Officer: Donald Norwood
Notification Date: 03/09/2022
Notification Time: 00:47 [ET]
Event Date: 03/08/2022
Event Time: 19:19 [EST]
Last Update Date: 03/09/2022
Notification Time: 00:47 [ET]
Event Date: 03/08/2022
Event Time: 19:19 [EST]
Last Update Date: 03/09/2022
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
Hanna, John (R3DO)
FFD Group, (EMAIL)
Hanna, John (R3DO)
FFD Group, (EMAIL)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
EN Revision Imported Date: 3/11/2022
EN Revision Text: FITNESS-FOR-DUTY REPORT - CONTRACT SUPERVISOR FAILED FITNESS-FOR-DUTY TEST
The following information was provided by the licensee via phone and email:
A non-licensed, contract employee supervisor had a confirmed positive for alcohol during a follow-up fitness-for-duty test. The employee's access to the plant has been terminated.
The NRC Resident Inspector has been notified.
EN Revision Text: FITNESS-FOR-DUTY REPORT - CONTRACT SUPERVISOR FAILED FITNESS-FOR-DUTY TEST
The following information was provided by the licensee via phone and email:
A non-licensed, contract employee supervisor had a confirmed positive for alcohol during a follow-up fitness-for-duty test. The employee's access to the plant has been terminated.
The NRC Resident Inspector has been notified.
Power Reactor
Event Number: 55780
Facility: Brunswick
Region: 2 State: NC
Unit: [2] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: Jason Krupp
HQ OPS Officer: Dan Livermore
Region: 2 State: NC
Unit: [2] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: Jason Krupp
HQ OPS Officer: Dan Livermore
Notification Date: 03/09/2022
Notification Time: 23:20 [ET]
Event Date: 03/09/2022
Event Time: 20:13 [EST]
Last Update Date: 03/09/2022
Notification Time: 23:20 [ET]
Event Date: 03/09/2022
Event Time: 20:13 [EST]
Last Update Date: 03/09/2022
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
10 CFR Section:
50.72(b)(3)(v)(D) - Accident Mitigation
Person (Organization):
Miller, Mark (R2DO)
Miller, Mark (R2DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
EN Revision Imported Date: 3/11/2022
EN Revision Text: HIGH PRESSURE COOLANT INJECTION (HPCI) INOPERABLE
The following information was provided by the licensee:
"At 2013 EST on March 9, 2022, the HPCI System was declared inoperable following evaluation of routine HPCI surveillance testing data indicating that the required response time for reaching rated conditions was not met. Therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v)(D). The Reactor Core Isolation Cooling (RCIC) System and Automatic Depressurization System (ADS) are operable.
"There was no impact on the health and safety of the public or plant personnel. Investigation is in-progress to determine the cause.
"Unit 1 is not affected by this event. Unit 1 is in a refueling outage.
"The NRC Resident Inspector has been notified."
EN Revision Text: HIGH PRESSURE COOLANT INJECTION (HPCI) INOPERABLE
The following information was provided by the licensee:
"At 2013 EST on March 9, 2022, the HPCI System was declared inoperable following evaluation of routine HPCI surveillance testing data indicating that the required response time for reaching rated conditions was not met. Therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v)(D). The Reactor Core Isolation Cooling (RCIC) System and Automatic Depressurization System (ADS) are operable.
"There was no impact on the health and safety of the public or plant personnel. Investigation is in-progress to determine the cause.
"Unit 1 is not affected by this event. Unit 1 is in a refueling outage.
"The NRC Resident Inspector has been notified."
Agreement State
Event Number: 55766
Rep Org: PA Bureau of Radiation Protection
Licensee: Reading Hospital
Region: 1
City: Reading State: PA
County:
License #: PA-0023
Agreement: Y
Docket:
NRC Notified By: John Chippo
HQ OPS Officer: Thomas Herrity
Licensee: Reading Hospital
Region: 1
City: Reading State: PA
County:
License #: PA-0023
Agreement: Y
Docket:
NRC Notified By: John Chippo
HQ OPS Officer: Thomas Herrity
Notification Date: 03/04/2022
Notification Time: 11:23 [ET]
Event Date: 03/03/2022
Event Time: 00:00 [EST]
Last Update Date: 03/04/2022
Notification Time: 11:23 [ET]
Event Date: 03/03/2022
Event Time: 00:00 [EST]
Last Update Date: 03/04/2022
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
Lilliendahl, Jon (R1)
NMSS_Events_Notification, (EMAIL)
Lilliendahl, Jon (R1)
NMSS_Events_Notification, (EMAIL)
EN Revision Imported Date: 3/11/2022
EN Revision Text: AGREEMENT STATE - UNDERDOSE
The following was received from the Commonwealth of Pennsylvania, Department of Environmental Protection (DEP) via e-mail:
"On March 3, 2022 a patient was receiving a Lutetium-177 (Lutatherar) treatment. During treatment, the vial lost pressure resulting in the inability to deliver the majority of the dose to the patient. Remedial measures were attempted, such as Dermabond and the addition of air, however, the procedure still could not continue, and it was terminated. No contamination was found outside of the delivery box. The prescribed dose was 200 milliCuries and it is estimated that the patient received 1.4 milliCuries. An investigation into the cause of the event is underway by the licensee. No adverse effects to the patient are noted at this time and the patient and prescribing physician have been informed. The DEP will update this event as soon as more information is provided."
PA Event Report ID No: PA220009
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
EN Revision Text: AGREEMENT STATE - UNDERDOSE
The following was received from the Commonwealth of Pennsylvania, Department of Environmental Protection (DEP) via e-mail:
"On March 3, 2022 a patient was receiving a Lutetium-177 (Lutatherar) treatment. During treatment, the vial lost pressure resulting in the inability to deliver the majority of the dose to the patient. Remedial measures were attempted, such as Dermabond and the addition of air, however, the procedure still could not continue, and it was terminated. No contamination was found outside of the delivery box. The prescribed dose was 200 milliCuries and it is estimated that the patient received 1.4 milliCuries. An investigation into the cause of the event is underway by the licensee. No adverse effects to the patient are noted at this time and the patient and prescribing physician have been informed. The DEP will update this event as soon as more information is provided."
PA Event Report ID No: PA220009
A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.