Event Number: 55397
Rep Org: TEXAS DEPT OF STATE HEALTH SERVICES
Licensee: Total Petrochemicals & Refining USA, Inc.
Region: 4
City: Port Arthur   State: TX
County:
License #: L 03498
Agreement: Y
Docket:
NRC Notified By: Matt Kennington
HQ OPS Officer: Thomas Kendzia
Notification Date: 08/05/2021
Notification Time: 11:39 [ET]
Event Date: 08/04/2021
Event Time: 00:00 [CDT]
Last Update Date: 08/05/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
GEPFORD, HEATHER (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
Event Text
EN Revision Imported Date: 9/3/2021

EN Revision Text: AGREEMENT STATE REPORT - STUCK SHUTTER

The following was received from the Texas Department of State Health Services (Agency) via email:

"On August 4, 2021, a consultant for the licensee reported to the Agency a stuck shutter on a VEGA SHLG-2 fixed gauge with a 5 Ci Cs-137 source. The shutter is stuck in the open position. Open is the normal operating position. The gauge is located at the top of a ladder and does not pose an increased risk of exposure due to the malfunction. The licensee has contacted the manufacturer for repair."

Texas incident number: I-9872



Power Reactor
Event Number: 55440
Facility: South Texas
Region: 4     State: TX
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Keith Mink
HQ OPS Officer: Joanna Bridge
Notification Date: 08/31/2021
Notification Time: 16:00 [ET]
Event Date: 08/04/2021
Event Time: 12:00 [CDT]
Last Update Date: 08/31/2021
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
JOSEY, JEFFREY (R4)
FFD GROUP, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
EN Revision Imported Date: 9/30/2021

EN Revision Text: LICENSED OPERATOR VIOLATED FFD POLICY

On August 4, 2021 a Licensed Reactor Operator violated the station's FFD policy. The employee's unescorted access to South Texas has been terminated. The event was determined to be reportable under 10 CFR 26.719(b)(2)(ii).

The NRC Resident Inspector will be been notified.


Agreement State
Event Number: 55471
Rep Org: COLORADO DEPT OF HEALTH
Licensee: T-Mobile - Greeley
Region: 4
City: Greeley   State: CO
County:
License #: GL002207
Agreement: Y
Docket:
NRC Notified By: Kathryn Mote
HQ OPS Officer: Donald Norwood
Notification Date: 09/17/2021
Notification Time: 13:46 [ET]
Event Date: 08/04/2021
Event Time: 00:00 [MDT]
Last Update Date: 09/17/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
AZUA, RAY (R4)
NMSS_EVENTS_NOTIFICATION, (EMAIL)
ILTAB, (EMAIL)
Event Text
EN Revision Imported Date: 10/15/2021

EN Revision Text: AGREEMENT STATE REPORT - FOUR LOST TRITIUM EXIT SIGNS

The following was received from the Colorado Department of Health via email:

"Four exit signs, each containing 6.2 Ci of tritium, were reported as lost during annual registration. New owner as of 04/01/2021. Upon inspecting the property, unable to locate signs registered with the State."

NMED No.: CO210029

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Part 21
Event Number: 55505
Rep Org: FLOWSERVE
Licensee:
Region: 1
City: Lynchburg   State: VA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: Chris Shaffer
HQ OPS Officer: Brian Lin
Notification Date: 10/04/2021
Notification Time: 12:04 [ET]
Event Date: 08/04/2021
Event Time: 00:00 [EDT]
Last Update Date: 10/04/2021
Emergency Class: Non Emergency
10 CFR Section:
21.21(d)(3)(i) - Defects And Noncompliance
Person (Organization):
MILLER, MARK (R2DO)
PART 21/50.55 REACTORS, - (EMAIL)
Event Text
EN Revision Imported Date: 11/4/2021

EN Revision Text: PART 21 - ACTUATOR FAILURE

The following is a summary of the report provided by Flowserve:

Flowserve - Limitorque was notified by Framatome Nuclear Parts Center that TVA Browns Ferry Nuclear (BFN) plant reported that a Limitorque SMB actuator had failed to operate electrically. It was noted by TVA that the actuator failure was discovered following a recent steam leak in the vicinity of the actuator. Investigation at BFN identified the failed component as the DC electric motor. The motor was removed from the actuator and disassembled by BFN personnel. Subsequently the motor was returned to Flowserve - Limitorque for evaluation. The subject motor is designated as a safety related basic component. Flowserve' s investigation, in conjunction with the motor original equipment manufacturer (OEM), has concluded that during manufacture, the subject motor sustained mechanical damage to the stator assembly field coil which led to the failure. As the dedicating entity, Flowserve is reporting this deviation in the assembly of the motor as a defect per the requirements of 10 CFR 21. Flowserve's investigation has concluded that this manufacturing defect is an isolated occurrence. No other instances of similar mechanical damage to the stator field coil insulation of Peerless DC motors have been observed or reported. The defect is specific to a quantity of one motor originally supplied to Framatome NPC on Limitorque Order Number 164879.001. This motor was subsequently supplied to the TVA Browns Ferry Nuclear Plant.

Identification of Component: Limitorque part # P-140-851-18F0
Description: Peerless 7.5 ft-lb, 250 volt DC motor
Serial Number: E18-99091-2 manufactured in August 2018

Corrective Actions to Date: The motor OEM is implementing additional assembly controls and quality control verification concerning the installation and final appearance of the coil support rod that damaged the stator field coil. This action, to be completed by October 15, 2021 will supplement the existing inspection checks on fully assembled motors, which includes insulation resistance tests and high potential tests which verify the integrity of the motor insulation system.

Technical questions concerning this notification can be directed to Kyle Ramsey, Engineering Specialist, Flowserve - Limitorque Actuation Systems: kramsey@flowserve.com