Event Notification Report for August 17, 2012
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/16/2012 - 08/17/2012
EVENT NUMBERS
48199482004820248205
Power Reactor
Event Number: 48199
Facility: ROBINSON
Region: 2 State: SC
Unit: [2] [] []
RX Type: [2] W-3-LP
NRC Notified By: BRIAN DALE
HQ OPS Officer: STEVE SANDIN
Region: 2 State: SC
Unit: [2] [] []
RX Type: [2] W-3-LP
NRC Notified By: BRIAN DALE
HQ OPS Officer: STEVE SANDIN
Notification Date: 08/17/2012
Notification Time: 06:32 [ET]
Event Date: 08/17/2012
Event Time: 05:52 [EDT]
Last Update Date: 08/17/2012
Notification Time: 06:32 [ET]
Event Date: 08/17/2012
Event Time: 05:52 [EDT]
Last Update Date: 08/17/2012
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
EUGENE GUTHRIE (R2DO)
ERIC THOMAS (NRR)
WILLIAM GOTT (IRD)
BRUCE BOGER (NRR)
VICTOR McCREE (R2 R)
EUGENE GUTHRIE (R2DO)
ERIC THOMAS (NRR)
WILLIAM GOTT (IRD)
BRUCE BOGER (NRR)
VICTOR McCREE (R2 R)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
UNUSUAL EVENT DECLARED DUE TO THE UNPLANNED LOSS OF ANNUNCIATORS > 15 MINUTES
At 0552 EDT Control Room Operators experienced a Loss of Annunciators. At 0607 EDT, the licensee declared an Unusual Event per EAL SU4.1, " Unplanned loss of most or all Annunciators or Indicators associated with Safety Systems on the RTGB [Remote Turbine Gage Board] Sections A and B, Primary System Annunciators and Indicators > 15 minutes." During an alarm test, the annunciators lit up as expected but did not clear at the completion of the test.
Exit criteria for the Unusual Event will be restoration of the annunciator functions. The licensee has compensatory measures in effect. ERFIS [Emergency Response Facility Information System] and the normal RTGB instruments are available.
The licensee notified the state and informed the NRC Resident Inspector. Notified Other FEDS (FEMA, DHS and NNSA via email).
* * * UPDATE FROM HILL TO KLCO ON 8/17/2012 AT 0954 EDT * * *
On August 17, 2012 at 0940 EDT, the licensee terminated the Unusual Event based on restoring annunciator capability. The licensee notified the NRC Resident Inspector and has terminated ERDS transmission.
Notified NRR-EO(Thomas), R2DO(Guthrie), IRD(Gott) and other FEDS (FEMA, DHS and NNSA via email)
At 0552 EDT Control Room Operators experienced a Loss of Annunciators. At 0607 EDT, the licensee declared an Unusual Event per EAL SU4.1, " Unplanned loss of most or all Annunciators or Indicators associated with Safety Systems on the RTGB [Remote Turbine Gage Board] Sections A and B, Primary System Annunciators and Indicators > 15 minutes." During an alarm test, the annunciators lit up as expected but did not clear at the completion of the test.
Exit criteria for the Unusual Event will be restoration of the annunciator functions. The licensee has compensatory measures in effect. ERFIS [Emergency Response Facility Information System] and the normal RTGB instruments are available.
The licensee notified the state and informed the NRC Resident Inspector. Notified Other FEDS (FEMA, DHS and NNSA via email).
* * * UPDATE FROM HILL TO KLCO ON 8/17/2012 AT 0954 EDT * * *
On August 17, 2012 at 0940 EDT, the licensee terminated the Unusual Event based on restoring annunciator capability. The licensee notified the NRC Resident Inspector and has terminated ERDS transmission.
Notified NRR-EO(Thomas), R2DO(Guthrie), IRD(Gott) and other FEDS (FEMA, DHS and NNSA via email)
Power Reactor
Event Number: 48200
Facility: BROWNS FERRY
Region: 2 State: AL
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: JOHN RIDINGER
HQ OPS Officer: JOHN SHOEMAKER
Region: 2 State: AL
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: JOHN RIDINGER
HQ OPS Officer: JOHN SHOEMAKER
Notification Date: 08/17/2012
Notification Time: 12:20 [ET]
Event Date: 08/17/2012
Event Time: 04:50 [CDT]
Last Update Date: 08/17/2012
Notification Time: 12:20 [ET]
Event Date: 08/17/2012
Event Time: 04:50 [CDT]
Last Update Date: 08/17/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
EUGENE GUTHRIE (R2DO)
EUGENE GUTHRIE (R2DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
INADVERTENT ACTUATION OF PRIMARY CONTAINMENT ISOLATION SYSTEM
"On 08/17/2012, while performing 2-SR-3.3.6.1(3DFT) - HPCI [High Pressure Coolant Injection] Steam Line Space Temperature Functional Test, an inadvertent PCIS [Primary Containment Isolation Signal] Group 4 (HPCI) isolation signal occurred. All automatic actions occurred as designed. Cause of the isolation is unknown with investigation in progress.
"This incident is reportable as an 8-hour ENS notification under 10 CFR 50.72 (b)(3)(v)(D).
"The incident also requires a 60 day written report.
"The NRC [Resident] Inspector has been notified."
The steam supply valves to HPCI remain closed during trouble shooting and repair, however, HPCI remains available for use if needed.
"On 08/17/2012, while performing 2-SR-3.3.6.1(3DFT) - HPCI [High Pressure Coolant Injection] Steam Line Space Temperature Functional Test, an inadvertent PCIS [Primary Containment Isolation Signal] Group 4 (HPCI) isolation signal occurred. All automatic actions occurred as designed. Cause of the isolation is unknown with investigation in progress.
"This incident is reportable as an 8-hour ENS notification under 10 CFR 50.72 (b)(3)(v)(D).
"The incident also requires a 60 day written report.
"The NRC [Resident] Inspector has been notified."
The steam supply valves to HPCI remain closed during trouble shooting and repair, however, HPCI remains available for use if needed.
Fuel Cycle Facility
Event Number: 48202
Facility: GLOBAL NUCLEAR FUEL - AMERICAS
Region: 2 State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: SCOTT MURRAY
HQ OPS Officer: MARK ABRAMOVITZ
Region: 2 State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: SCOTT MURRAY
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 08/17/2012
Notification Time: 13:36 [ET]
Event Date: 08/17/2012
Event Time: 12:39 [EDT]
Last Update Date: 08/17/2012
Notification Time: 13:36 [ET]
Event Date: 08/17/2012
Event Time: 12:39 [EDT]
Last Update Date: 08/17/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
PART 70 APP A (a)(5) - ONLY ONE SAFETY ITEM AVAILABLE
10 CFR Section:
PART 70 APP A (a)(5) - ONLY ONE SAFETY ITEM AVAILABLE
Person (Organization):
EUGENE GUTHRIE (R2DO)
MICHAEL WATERS (NMSS)
EUGENE GUTHRIE (R2DO)
MICHAEL WATERS (NMSS)
ONLY ONE IROFS AVAILABLE FOR A SPILL IN THE CERAMICS AREA
"At 12:39 PM (EDT) it was discovered that only one Items Relied On For Safety (IROFS) remained in place to prevent a Criticality Event in the ceramics area of the Fuel Manufacturing Operations facility. The failed IROFS was Fuel Business System (FBS) Control of Mass of Uranium Transportable Container (IROFS 900-01), due to an overweight pellet boat. The IROFS that remained in place at all times was Spill Identification and Cleanup (IROFS 900-11). The initiating event for the accident sequences (spill of a pellet boat) did not occur."
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 1456 EDT ON 8/17/2012 FROM SCOTT MURRAY TO MARK ABRAMOVITZ * * *
"The pellets have been removed from the overweight boat and placed into an approved container; the IROFS for these accident sequences have been restored. The extent of condition is being evaluated and at this time no other overweight boats have been identified.
"Region II and NMSS HQ and other notifications have been completed."
Notified the R2DO (Guthrie) and NMSS (Waters).
"At 12:39 PM (EDT) it was discovered that only one Items Relied On For Safety (IROFS) remained in place to prevent a Criticality Event in the ceramics area of the Fuel Manufacturing Operations facility. The failed IROFS was Fuel Business System (FBS) Control of Mass of Uranium Transportable Container (IROFS 900-01), due to an overweight pellet boat. The IROFS that remained in place at all times was Spill Identification and Cleanup (IROFS 900-11). The initiating event for the accident sequences (spill of a pellet boat) did not occur."
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 1456 EDT ON 8/17/2012 FROM SCOTT MURRAY TO MARK ABRAMOVITZ * * *
"The pellets have been removed from the overweight boat and placed into an approved container; the IROFS for these accident sequences have been restored. The extent of condition is being evaluated and at this time no other overweight boats have been identified.
"Region II and NMSS HQ and other notifications have been completed."
Notified the R2DO (Guthrie) and NMSS (Waters).
Non-Agreement State
Event Number: 48205
Rep Org: PSC ENVIRONMENTAL SERVICES LLC
Licensee: PSC ENVIRONMENTAL SERVICES LLC
Region: 3
City: DETROIT State: MI
County:
License #: GL
Agreement: N
Docket:
NRC Notified By: GREG INK
HQ OPS Officer: MARK ABRAMOVITZ
Licensee: PSC ENVIRONMENTAL SERVICES LLC
Region: 3
City: DETROIT State: MI
County:
License #: GL
Agreement: N
Docket:
NRC Notified By: GREG INK
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 08/17/2012
Notification Time: 16:50 [ET]
Event Date: 08/17/2012
Event Time: 00:00 [EDT]
Last Update Date: 08/17/2012
Notification Time: 16:50 [ET]
Event Date: 08/17/2012
Event Time: 00:00 [EDT]
Last Update Date: 08/17/2012
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
JOHN GIESSNER (R3DO)
FSME EVENTS RESOURCE (FSME)
JOHN GIESSNER (R3DO)
FSME EVENTS RESOURCE (FSME)
TEN TRITIUM EXIT SIGNS DAMAGED
Ten tritium exit signs belonging to Bed Bath and Beyond were inadvertently placed into a compactor and damaged. The signs originally contained 7.5 Ci of tritium when they were purchased 7-10 years ago. Shaw Environmental will take smears of the site next week to determine if there is residual contamination or cleanup required. The signs have been placed in drums and the area quarantined.
See report of this same event from the State of Wisconsin EN #48224
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source
Ten tritium exit signs belonging to Bed Bath and Beyond were inadvertently placed into a compactor and damaged. The signs originally contained 7.5 Ci of tritium when they were purchased 7-10 years ago. Shaw Environmental will take smears of the site next week to determine if there is residual contamination or cleanup required. The signs have been placed in drums and the area quarantined.
See report of this same event from the State of Wisconsin EN #48224
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source