Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for December 17, 2008

U.S. Nuclear Regulatory Commission
Operations Center

Event Reports For
12/16/2008 - 12/17/2008

** EVENT NUMBERS **


44712 44724

To top of page
General Information or Other Event Number: 44712
Rep Org: OHIO BUREAU OF RADIATION PROTECTION
Licensee: COMMUNITY REGIONAL MEDICAL CENTER
Region: 3
City: LORAIN State: OH
County:
License #: 02120480002
Agreement: Y
Docket:
NRC Notified By: MARK LIGHT
HQ OPS Officer: JOE O'HARA
Notification Date: 12/11/2008
Notification Time: 08:34 [ET]
Event Date: 12/10/2008
Event Time: 14:00 [EST]
Last Update Date: 12/11/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
CHRISTINE LIPA (R3)
TERRY REIS (FSME)

Event Text

DETECTABLE CESIUM CONTAMINATION FOUND IN SOURCE SAFE DRAWER

A contractor removed cesium sources from a source safe located in a storage area. The sources were removed, packaged, shipped without incident. Surveys were conducted in the safe, and the survey in the lower safe drawer revealed contamination levels greater than 5000 dpm per 100 square centimeters. The lower drawer of the safe has not been used during this recent storage and transfer of sources. The licensee reported to the state that they believed it was "legacy" contamination. Individuals involved in the source transfer were surveyed. No contamination was found. The storage area and passageway to and from the storage area were surveyed. No contamination was found. The licensee has secured the safe and the contaminated area. The area is secured and posted with "no access" signs. The state will follow up with their licensee once a decontamination service completes the decontamination of the affected areas and is ready to release the area for general use.

The state notified Region 3 (Jim Lynch).

To top of page
Fuel Cycle Facility Event Number: 44724
Facility: GLOBAL NUCLEAR FUEL - AMERICAS
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
                   LEU FABRICATION
                   LWR COMMERICAL FUEL
Region: 2
City: WILMINGTON State: NC
County: NEW HANOVER
License #: SNM-1097
Agreement: Y
Docket: 07001113
NRC Notified By: SCOTT MURRAY
HQ OPS Officer: HOWIE CROUCH
Notification Date: 12/16/2008
Notification Time: 16:23 [ET]
Event Date: 12/16/2008
Event Time: 06:00 [EST]
Last Update Date: 12/16/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
70.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
JAY HENSON (R2)
PETER HABIGHORST (NMSS)

Event Text

CRITICALITY WARNING SYSTEM DISABLED

"At approximately 0600 on 12/16/2008, the horns of the inside Criticality Warning System (CWS) covering the Fuel Manufacturing Operation (FMO) were discovered to be in manual mode. On 12/12/08 at approximately 0700, the horns had been taken out of automatic mode and placed in manual mode as part of system maintenance activities at 0700 and inadvertently remained in this condition until this morning at 0600. According to a preliminary investigation, it appears that following maintenance on 12/12/08, incomplete system restoration left the automatic horn function disabled but the detection system remained operational.

"Once identified, the system was immediately restored to the automatic mode and the inside FMO CWS system was returned to normal operation. Follow-up tests have confirmed that the warning system horns are fully operational.

"The event is being reported within 24-hours pursuant to 10CFR70.50(b)(2) as an event in which safety equipment was disabled."

During the time that the warning system was disabled, there were no conditions that would have resulted in warning system activation. Corrective actions have been taken to prevent re-occurrence. The licensee will be notifying NRC Region 2 as well as State and local governments.

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021