Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for March 27, 2003




                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           03/26/2003 - 03/27/2003



                              ** EVENT NUMBERS **



39685  39689  39701  39702  39703  39704  



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39685       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 03/21/2003|

|LICENSEE:  LAW ENGINEERING & ENVIRONMENTAL SERVI|NOTIFICATION TIME: 11:58[EST]|

|    CITY:  FORT WORTH               REGION:  4  |EVENT DATE:        03/21/2003|

|  COUNTY:                            STATE:  TX |EVENT TIME:        03:40[CST]|

|LICENSE#:  L05490-000            AGREEMENT:  Y  |LAST UPDATE DATE:  03/21/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |CLAUDE JOHNSON       R4      |

|                                                |LARRY CAMPER         NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  JAMES H. OGDEN, JR.          |                             |

|  HQ OPS OFFICER:  ARLON COSTA                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT: STOLEN TROXLER MOISTURE DENSITY GAUGE                |

|                                                                              |

| "Gauge operator was working the swing shift supporting operations of         |

| construction of the Dallas Area Rapid Transit (DART) in Dallas, Texas.       |

| Enroute to company office, he stopped by his residence from 3:00 a.m. to     |

| 3:40 a.m. for breakfast.  Before departing for the storage location, 2200    |

| Gravel Drive, Fort Worth, he noted that the gauge and chain were missing     |

| from his company [Law Engineering & Environmental Services, Inc.] truck      |

| (Black Ford, F-150).  The stolen gauge is a Troxler 3411 B, Serial No.       |

| 10732, with two sealed sources: Cs-137, 8 millicuries, Serial No. 40-8208    |

| and AM-241/Be, 40 millicuries, Serial No. 46-2134.  A report of the theft    |

| was made to the White Settlement Police Department and to his supervisor,    |

| [DELETED].  The gauge, chain, and lock are completely missing from the       |

| vehicle.                                                                     |

|                                                                              |

| "Licensee notified White Settlement Police Department, and Texas Department  |

| of Health/Bureau of Radiation Control, TDH/BRC will notify NRC, INEEL,       |

| Troxler Electronic Labs, and the states of Arizona, Arkansas, Louisiana, New |

| Mexico, and Oklahoma, as well as, the country of Mexico.                     |

|                                                                              |

| "Media attention: None at this time.  Licensee is debating notifications to  |

| local media and possibly offering a reward for return of the gauge."         |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39689       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  ALABAMA RADIATION CONTROL            |NOTIFICATION DATE: 03/22/2003|

|LICENSEE:  GALLET AND ASSOCIATES                |NOTIFICATION TIME: 18:44[EST]|

|    CITY:  HOMEWOOD                 REGION:  2  |EVENT DATE:        03/22/2003|

|  COUNTY:                            STATE:  AL |EVENT TIME:        09:30[CST]|

|LICENSE#:  991                   AGREEMENT:  Y  |LAST UPDATE DATE:  03/22/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |CAUDLE JULIAN        R2      |

|                                                |LARRY CAMPER         NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  JAMES L. MCNEES              |                             |

|  HQ OPS OFFICER:  ARLON COSTA                  |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NAGR                     AGREEMENT STATE        |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AGREEMENT STATE REPORT: STOLEN MOISTURE DENSITY GAUGE                        |

|                                                                              |

| "At 11:12 a.m. on Saturday March 22, 2003 James L. McNees of the Office of   |

| Radiation Control was contacted at his home by Mr. Tad Nelson of Gallet and  |

| Associates, (Alabama Radioactive Material License No. 991) and notified that |

| at approximately 10:00 a.m. this morning that a Campbell Pacific model MC-3  |

| moisture density gauge had been stolen from the back of a company pickup     |

| truck at an employee's home.  Nelson stated that the Homewood (Alabama)      |

| Police Department was currently at the location investigating.  The device   |

| contains approximately 10 mCi [millicuries] of Cs-137 and 40 mCi             |

| [millicuries] of Am-241.  Nelson further stated that the shipping container  |

| housing the device was locked, as was the control mechanism on the device,   |

| and that the thief(s) reportedly obtained the device by cutting the chain by |

| which the shipping container was locked to the bed of the truck.             |

|                                                                              |

| "Alabama Emergency Management Agency was notified at 11:28 a.m., who [in     |

| turn] alerted other civil authorities in the Jefferson County area.  The     |

| principal concern being that once the thief discovers that the stolen device |

| has little value at sale, and is hazardous, that it will be abandoned.       |

|                                                                              |

| "Mr. Nelson agreed that if the device was not recovered by this afternoon    |

| that a press release should be made.  At 5:00 p.m. today, March 22, 2003,    |

| the writer was informed by Mr. Nelson that the device had not been           |

| recovered.  Both agreed that Gallet and Associates should forward the        |

| attached press release to local Jefferson County media outlets.              |

|                                                                              |

| The Licensee, Gullet & Associates, issued the following Press Release on     |

| March 22, 2003:                                                              |

|                                                                              |

| "Around or before 9:30 on March 22, 2003, a moisture-density gauge           |

| containing sealed sources of radioactive material was stolen from its case   |

| locked to a truck owned by Gallet & Associates, Inc. of Birmingham, Alabama. |

| The truck was parked at a home in the Edgewood community of Homewood,        |

| Alabama near the Palisades Shopping Center.  The Homewood Police Department  |

| was notified and is continuing their investigation.                          |

|                                                                              |

| "The Attached is a sketch of the gauge stolen.  Labels indicating the device |

| is radioactive should be visible on the gauge itself.  Normally the          |

| radioactive sealed source is locked in a safe position.  The device does not |

| pose a health hazard as long as it is not tampered with or handled by        |

| untrained individuals.  Please notify the Homewood Police Department at      |

| (205) 877-8637, Gallet & Associates, Inc. at (205) 942-1289, the Alabama     |

| Division of Radiation Control at 1-800-582-1866, or your local police        |

| department if found.                                                         |

|                                                                              |

| "Since the device and sale of such is regulated it therefore has no resale   |

| value and can only be used to determine the moisture content and density of  |

| soils by licensed, qualified personnel.                                      |

|                                                                              |

| "A reward is offered for the recovery or information leading to the recovery |

| of the device."                                                              |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39701       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 03/26/2003|

|    UNIT:  [1] [2] []                STATE:  PA |NOTIFICATION TIME: 00:30[EST]|

|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/25/2003|

+------------------------------------------------+EVENT TIME:        23:58[EST]|

| NRC NOTIFIED BY:  ROBERT BOESCH                |LAST UPDATE DATE:  03/26/2003|

|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |PAMELA HENDERSON     R1      |

|10 CFR SECTION:                                 |                             |

|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          Y       100      Power Operation  |100      Power Operation  |

|2     N          N       0        Refueling        |0        Refueling        |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| OFFSITE NOTIFICATION OF MEDICAL CONDITION                                    |

|                                                                              |

| "On 3/25/03 at 23:45 [EST] the Main Control Room was notified that an        |

| individual with a medical condition (believed to be a kidney stone) needed   |

| to be transported to the hospital by ambulance.  An ambulance was dispatched |

| to the site.   The individual was not contaminated.   The individual was     |

| transported to a local hospital for treatment.                               |

|                                                                              |

| "The Pennsylvania Emergency Management Agency was notified at 23:58 [EST].   |

| Due to notification to another government agency, this event is reportable   |

| under 10CFR50.72(b)(2)(xi)."                                                 |

|                                                                              |

| The licensee notified the NRC Resident Inspector.                            |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39702       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: BROWNS FERRY             REGION:  2  |NOTIFICATION DATE: 03/26/2003|

|    UNIT:  [] [2] []                 STATE:  AL |NOTIFICATION TIME: 06:04[EST]|

|   RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4           |EVENT DATE:        03/26/2003|

+------------------------------------------------+EVENT TIME:        02:45[CST]|

| NRC NOTIFIED BY:  JOE BENNET                   |LAST UPDATE DATE:  03/26/2003|

|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |RUDOLPH BERNHARD     R2      |

|10 CFR SECTION:                                 |                             |

|ASHU 50.72(b)(2)(i)      PLANT S/D REQD BY TS   |                             |

|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|                                                   |                          |

|2     M/R        Y       61       Power Operation  |0        Hot Shutdown     |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| SHUTDOWN REQUIRED BY TECHNICAL SPECIFICATIONS                                |

|                                                                              |

| "On 3/26/03 at 02:45 [CST], Unit 2 experienced a trip of the 2B              |

| Recirculation system variable frequency drive (VFD).  The 2A VFD had tripped |

| earlier in the shift.  This resulted in entry into Technical Specification   |

| 3.4.1 .B, which requires the plant to be placed in Mode 3 within 12 hours.   |

| The unit was manually scrammed at this time in accordance with plant         |

| procedures.                                                                  |

|                                                                              |

| "This event is reportable within 4 hours per 10CFR 50.72 (b)(2)(i) as 'The   |

| initiation of any nuclear plant shutdown required by the plant's Technical   |

| Specifications'.  It is also reportable per 10CFR 50.72(b)(3)(iv)(A) and     |

| 10CFR 50.73(a)(2)(i)(A) and (iv)(B)."                                        |

|                                                                              |

| The cause of the Recirculation System VFD is being investigated.  The        |

| licensee notified the NRC Resident Inspector.                                |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Hospital                                         |Event Number:   39703       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  DOYLESTOWN HOSPITAL                  |NOTIFICATION DATE: 03/26/2003|

|LICENSEE:  DOYLESTOWN HOSPITAL                  |NOTIFICATION TIME: 11:10[EST]|

|    CITY:  DOYLESTOWN               REGION:  1  |EVENT DATE:        03/25/2003|

|  COUNTY:                            STATE:  PA |EVENT TIME:        09:00[EST]|

|LICENSE#:  37-13234-01           AGREEMENT:  N  |LAST UPDATE DATE:  03/26/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |PAMELA HENDERSON     R1      |

|                                                |TOM ESSIG            NMSS    |

+------------------------------------------------+                             |

| NRC NOTIFIED BY:  NUNNO                        |                             |

|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|LDIF 35.3045(a)(1)       DOSE <> PRESCRIBED DOSA|                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| MEDICAL EVENT WHICH INVOLVED EXCEEDING THE PRESCRIBED DOSE TO A PATIENT      |

|                                                                              |

| During a procedure using a Galileo 3 IVB made by Guidant, the company        |

| trainer was demonstrating how to conduct the procedure.  A "hot" (wire       |

| containing approximately 100 millicuries of P-32)  wire was to be inserted   |

| into the patient's coronary vessel, but prior to this a dummy wire was to be |

| inserted.  The dummy wire was inserted but not all the way.  It was removed  |

| and then the "hot" wire was inserted to the same position and then removed.  |

| It was then realized that it was not fully inserted, so they reinserted it   |

| to the full position realizing that the patient would get more that the      |

| prescribed dose of 2,000 rads (actual dose received was 2,833 rads or 41%    |

| more than the prescribed dose), but the treatment was needed by the patient. |

| There would be no adverse affects to the patient and both the patient and    |

| prescribing physician were notified.                                         |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|Power Reactor                                    |Event Number:   39704       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| FACILITY: SEQUOYAH                 REGION:  2  |NOTIFICATION DATE: 03/26/2003|

|    UNIT:  [1] [] []                 STATE:  TN |NOTIFICATION TIME: 11:16[EST]|

|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/26/2003|

+------------------------------------------------+EVENT TIME:        10:12[EST]|

| NRC NOTIFIED BY:  MICHAEL HOWARD               |LAST UPDATE DATE:  03/26/2003|

|  HQ OPS OFFICER:  MIKE RIPLEY                  +-----------------------------+

+------------------------------------------------+PERSON          ORGANIZATION |

|EMERGENCY CLASS:          NON EMERGENCY         |RUDOLPH BERNHARD     R2      |

|10 CFR SECTION:                                 |                             |

|ADEG 50.72(b)(3)(ii)(A)  DEGRADED CONDITION     |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |

+-----+----------+-------+--------+-----------------+--------+-----------------+

|1     N          N       0        Refueling Shutdow|0        Refueling Shutdow|

|                                                   |                          |

|                                                   |                          |

+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| REACTOR VESSEL HEAD DEGRADED CONDITION                                       |

|                                                                              |

| "During the unit 1 cycle 12 refueling and steam generator replacement        |

| outage, an inspection was performed of the vessel head in accordance with    |

| NRC Order EA-03-009.  This bare metal inspection identified a potential leak |

| indication at the head to penetration interface for CRDM (Control Rod Drive  |

| Mechanism) penetration #3.  On March 26, 2003, at approximately 1012 hours   |

| EST, it was decided that the chemical samples have confirmed that the        |

| residue found at this interface contains boron, iron, and zinc, indicating   |

| that this was an RCS leak.  This leak is most likely from a through wall     |

| crack in the RCS pressure boundary at the CRDM interface.  Volumetric exams  |

| are planned to confirm the crack and to determine the scope of any repairs.  |

| In accordance with the Order, a 100% volumetric inspection is being prepared |

| for this outage.  Prior to this identification, this unit was rated as a     |

| 'low susceptibility category.'  There had been no indication of RCS leakage  |

| during the previous cycle's operation.  This notification is being made in   |

| accordance with 10 CFR 50.72(b)(3)(ii)(A)."                                  |

|                                                                              |

| The licensee has notified the NRC Resident Inspector.                        |

+------------------------------------------------------------------------------+              

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021