Event Notification Report for March 13, 2003
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 03/12/2003 - 03/13/2003 ** EVENT NUMBERS ** 39655 39662 +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 39655 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 03/10/2003| |LICENSEE: PROFESSIONAL SERVICES INDUSTRIES, PSI|NOTIFICATION TIME: 14:54[EST]| | CITY: HOUSTON REGION: 4 |EVENT DATE: 03/08/2003| | COUNTY: STATE: TX |EVENT TIME: 12:45[CST]| |LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 03/10/2003| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |MARK SHAFFER R4 | | |KEVIN HSUEH NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: GLENN CORBIN | | | HQ OPS OFFICER: JOHN MacKINNON | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT: STOLEN TROXLER MOISTURE DENSITY GAUGE | | | | | | "A Troxler model #3430 (serial number 27095), portable moisture/density | | gauge was reported stolen from the Texas Medical Center construction project | | site located at 2450 Holcomb, Houston, Texas between 12:45 p.m. and 1:30 | | p.m. CT on Saturday, March 8, 2003. This device is bright yellow, | | approximately 11" long x 8" wide x 5" tall with two metal posts | | approximately 18" tall protruding from the top of the device and a locked | | handle at the top. The device contains two sealed sources (isotopes) | | double-encapsulated in stainless steel, and is licensed by the Texas | | Department of Health. When not in use, the device emits low-level energy | | equivalent to a single chest x-ray, which poses no threat unless the device | | is tampered with. | | | | "A police report has been filed with the Houston Police Department. | | | | "The company is offering a $500.00 reward for the return of the device on | | the 'no-questions-asked' bases. If found, please do not move the device and | | contact the Houston Police Department and refer to police report no. | | 032141303E. If anyone has any information regarding the theft of the device | | please [call PSI]." | | | | The State of Texas believes the Troxler moisture density gauge contains 10 | | millicuries of Cesium-137 and 40 millicuries of Am/Be-241. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 39662 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: FARLEY REGION: 2 |NOTIFICATION DATE: 03/12/2003| | UNIT: [1] [2] [] STATE: AL |NOTIFICATION TIME: 02:13[EST]| | RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 03/12/2003| +------------------------------------------------+EVENT TIME: 00:25[CST]| | NRC NOTIFIED BY: WAYNE VAN LANDINGHAM |LAST UPDATE DATE: 03/12/2003| | HQ OPS OFFICER: ERIC THOMAS +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |DAVID AYRES R2 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | FUEL OIL SPILL | | | | "At 0025 [on] 3/12/03, notification was made to offsite government agencies, | | the U.S. Coast Guard National Response Center and the Alabama Department of | | Environment Management. The notification was required because approximately | | 50 gallons of fuel oil were spilled on site reaching on site waters. | | Control measures were implemented to prevent oil from reaching navigable | | waters. Plant operations were unaffected." | | | | The source of the spill was the fuel oil storage tank for 2 "C" Emergency | | Diesel Generator. While in the process of filling the tank, the worker | | became distracted and did not secure at 96 percent full per procedure. This | | was not a 'reportable quantity'. | | | | The licensee notified the NRC Resident Inspector. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021