Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for March 7, 2003








                    U.S. Nuclear Regulatory Commission

                              Operations Center



                              Event Reports For

                           03/06/2003 - 03/07/2003



                              ** EVENT NUMBERS **



39638  39639  



+------------------------------------------------------------------------------+

|Transportation                                   |Event Number:   39638       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  STATE OF WV RAD HEALTH PROGRAM       |NOTIFICATION DATE: 03/06/2003|

|LICENSEE:  UNKNOWN                              |NOTIFICATION TIME: 01:24[EST]|

|    CITY:  PARKERSBURG              REGION:  2  |EVENT DATE:        03/06/2003|

|  COUNTY:                            STATE:  WV |EVENT TIME:        01:15[EST]|

|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  03/06/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |CAROLYN EVANS        R2      |

|                                                |C.W. (BILL) REAMER   NMSS    |

+------------------------------------------------+JOSEPH HOLONICH      IRO     |

| NRC NOTIFIED BY:  DAN HILL                     |NANCY OSGOOD         DOT     |

|  HQ OPS OFFICER:  HOWIE CROUCH                 |GIBSON               DOE     |

+------------------------------------------------+CAPT. HOLLAND        LLEA    |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|NINF                     INFORMATION ONLY       |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| AUTOMOBILE ACCIDENT INVOLVING RADIOGRAPHY SOURCE                             |

|                                                                              |

| At 0124 EST on 3/06/2003, NRC Headquarters was contacted by State of WV      |

| Radiation Health Program that an automobile/truck accident had occurred in   |

| Parkersburg, West Virginia that involved a Iridium-192 radiography source.   |

| Local HazMat responders do not have radiation monitoring equipment.          |

| Currently, LLEA is in contact with Camden-Clark Hospital to obtain proper    |

| radiation monitoring equipment to determine if packaging is intact.  (It was |

| determined that Camden-Clark is unable to respond). Vehicle is located in    |

| local towing impound yard.  West Virginia will be responding in the morning  |

| to perform surveys.                                                          |

|                                                                              |

| Notified NMSS EO (Reamer), R2DO (Evans), DIRO Mgr. (Holonich), NRC           |

| Transportation (Osgood), DOT (LT. (jg) Johnson) and DOE (Gibson).            |

|                                                                              |

| * * * * UPDATE FROM D. HILL TO M. RIPLEY AT 1250 EST 3/6/03 * * *            |

|                                                                              |

| The State of WV Radiation Health Program completed an inspection and         |

| radiation survey.   The Iridium-192 radiography source was found intact.     |

| Radiation levels were normal and there was no spread of radioactivity.  The  |

| radiography equipment was released to the licensee for transport back to the |

| work site where it was being used.                                           |

|                                                                              |

| Notified NMSS EO (Reamer), R2DO (Evans & Pelchat), DIRO Mgr. (Holonich),     |

| DOT-NRC Watch Officer, DOT (LT. Higgins), DOE Watch Officer, NTSB            |

| (Belchius), USCG (LT. Gross), EPA R3 (Minnick).                              |

+------------------------------------------------------------------------------+



+------------------------------------------------------------------------------+

|General Information or Other                     |Event Number:   39639       |

+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+

| REP ORG:  HOLTEC INTERNATIONAL                 |NOTIFICATION DATE: 03/06/2003|

|LICENSEE:  AALBORG                              |NOTIFICATION TIME: 14:10[EST]|

|    CITY:                           REGION:     |EVENT DATE:        01/03/2003|

|  COUNTY:                            STATE:     |EVENT TIME:             [EST]|

|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  03/06/2003|

|  DOCKET:                                       |+----------------------------+

|                                                |PERSON          ORGANIZATION |

|                                                |MOHAMED SHANBAKY     R1      |

|                                                |CAROLYN EVANS        R2      |

+------------------------------------------------+MONTE PHILLIPS       R3      |

| NRC NOTIFIED BY:  HOLTEC (fax)                 |DALE POWERS          R4      |

|  HQ OPS OFFICER:  MIKE RIPLEY                  |TERRY REIS           NRR     |

+------------------------------------------------+                             |

|EMERGENCY CLASS:          NON EMERGENCY         |                             |

|10 CFR SECTION:                                 |                             |

|CCCC 21.21               UNSPECIFIED PARAGRAPH  |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

|                                                |                             |

+------------------------------------------------------------------------------+



                                   EVENT TEXT                                   

+------------------------------------------------------------------------------+

| PART 21 NOTIFICATION - AALBORG FLOW METERS                                   |

|                                                                              |

| Holtec International reports a potential defect in Aalborg model GFM671S     |

| mass flow rate meters.  The instruments are used to verify the correct       |

| amount of helium is backfilled into dry spent fuel storage canisters.  These |

| instruments were never used on a Holtec cask system containing spent nuclear |

| fuel because the problem was discovered during the preparatory phase before  |

| fuel loading.                                                                |

|                                                                              |

| Four meters were purchased for use at the Trojan nuclear plant to measure    |

| the amount of helium gas injected into a loaded Holtec dry spent fuel        |

| Multipurpose Canister (MPC).  It was determined that erroneous data was      |

| coming from the flow rate meters. It was determined by Aalborg that the      |

| published correction factors for helium/nitrogen were incorrect for this     |

| model flow meter.  At the time the discrepant condition was identified, none |

| of the flow meters had been used on an MPC loaded with spent fuel and they   |

| were subsequently removed from service until they could be correctly         |

| calibrated.                                                                  |

|                                                                              |

| Four flow rate meters were procured and delivered to the Trojan nuclear      |

| power plant. Three were not used in actual fuel loading activities due to    |

| the discovery of the mis-calibration during dry run activities.  The fourth  |

| flow rate meter has been removed from the site.                              |

|                                                                              |

| Aalborg is developing new helium correction factors.  In the interim, they   |

| have committed to using helium to calibrate all flow meters destined for use |

| in measuring helium.                                                         |

|                                                                              |

| Trojan plant was the first plant where flow rate meters and flow totalizers  |

| were to be used to confirm adequate helium backfill in Holtec MPCs loaded    |

| with spent fuel.  Therefore, no other Holtec client is affected for past     |

| loading operations. For future MPC loading operations, Holtec users, as well |

| as other purchasers and licensees are being notified via this report that    |

| Aalborg flow meters procured for use in important-to-safety activities may   |

| not be calibrated correctly and that certain catalogue correction factors    |

| have been determined to be incorrect.  The calibration of Aalborg flow       |

| meters should be confirmed prior to use in important-to-safety activities.   |

+------------------------------------------------------------------------------+





                    