Event Notification Report for April 29, 2002
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 04/26/2002 - 04/29/2002 ** EVENT NUMBERS ** 38875 38878 38879 38880 38881 +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 38875 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: ALABAMA RADIATION CONTROL |NOTIFICATION DATE: 04/24/2002| |LICENSEE: UNIVERSITY OF ALABAMA MEDICAL CENTER |NOTIFICATION TIME: 18:10[EDT]| | CITY: BIRMINGHAM REGION: 2 |EVENT DATE: 04/24/2002| | COUNTY: STATE: AL |EVENT TIME: [CDT]| |LICENSE#: 266 AGREEMENT: Y |LAST UPDATE DATE: 04/24/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |ANNE BOLAND R2 | | |MELVYN LEACH NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: BRADLEY GRINSTEAD | | | HQ OPS OFFICER: RICH LAURA | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT OF LOST IRIDIUM-192 SOURCE | | | | The Alabama State Radiation Control Office reported that the University of | | Alabama Medical Center was missing a 250-millicurie iridium-192 source. The | | source is used for cardiology purposes and was last seen on April 22, 2002. | | The hospital was conducting searches to try to locate the missing source. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38878 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: INDIAN POINT REGION: 1 |NOTIFICATION DATE: 04/26/2002| | UNIT: [2] [] [] STATE: NY |NOTIFICATION TIME: 09:06[EDT]| | RXTYPE: [2] W-4-LP,[3] W-4-LP |EVENT DATE: 04/26/2002| +------------------------------------------------+EVENT TIME: 08:35[EDT]| | NRC NOTIFIED BY: JOHN BALLETTA |LAST UPDATE DATE: 04/26/2002| | HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |CLIFFORD ANDERSON R1 | |10 CFR SECTION: |TOM KOSHY NRR | |ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |2 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | EMERGENCY RESPONSE DATA SYSTEM (ERDS) INOPERABLE DUE TO PLANNED OUTAGE OF | | THE PLANT PROCESS COMPUTER SYSTEM | | | | The following text is a portion of a facsimile received from the licensee: | | | | "On [April 26, 2002,] at 0835 hours EDT, the Indian Point Unit 2 plant ERDS | | was taken out of service to perform planned modifications to the plant | | process computer system. ERDS will remain inoperable until approximately | | May 4, 2002." | | | | "This report is being made in accordance with the requirements of 10 CFR | | 50.72(b)(3)(xiii); any event that results in a loss of offsite | | communications capability." | | | | "The Senior Resident Inspector has been briefed on the modifications and | | schedule. The NRC was previously notified of this planned outage via letter | | dated April 4, 2002." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 38879 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: OHIO BUREAU OF RADIATION PROTECTION |NOTIFICATION DATE: 04/26/2002| |LICENSEE: RIVERSIDE METHODIST HOSPITAL |NOTIFICATION TIME: 13:06[EDT]| | CITY: COLUMBUS REGION: 3 |EVENT DATE: 04/23/2002| | COUNTY: STATE: OH |EVENT TIME: [EDT]| |LICENSE#: 02120-250070 AGREEMENT: Y |LAST UPDATE DATE: 04/26/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |JOHN JACOBSON R3 | | |DOUGLAS BROADDUS NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: MARK LIGHT | | | HQ OPS OFFICER: RICH LAURA | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT OF A MEDICAL MISADMINISTRATION | | | | A medical misadministration occurred on April 23, 2002 that resulted in the | | patient receiving a 36% overdose (i.e., 10.9 gray vice 8 gray) during | | brachytherapy to treat coronary vessels. The isotope being used for the | | treatment is IR-192. The error was discovered on April 25, 2002 when the | | hospital was setting up to treat another patient. Specifically, a wrong | | decay table was used in the calculations. No adverse effect on the patient | | was anticipated. The patient has been notified. | | | | The State reported that RIII (K. NULL) has been notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38880 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: MILLSTONE REGION: 1 |NOTIFICATION DATE: 04/26/2002| | UNIT: [] [] [3] STATE: CT |NOTIFICATION TIME: 16:10[EDT]| | RXTYPE: [1] GE-3,[2] CE,[3] W-4-LP |EVENT DATE: 04/26/2002| +------------------------------------------------+EVENT TIME: 15:51[EDT]| | NRC NOTIFIED BY: ROBERT SMITH |LAST UPDATE DATE: 04/26/2002| | HQ OPS OFFICER: RICH LAURA +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |CLIFFORD ANDERSON R1 | |10 CFR SECTION: |DAVID MATTHEWS NRR | |AUNA 50.72(b)(3)(ii)(B) UNANALYZED CONDITION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | | | | |3 N Y 100 Power Operation |100 Power Operation | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | POTENTIAL FOR HOT SHORTS IN PORV CIRCUITS | | | | "Recent review of Station Procedures regarding fire in the Control Room and | | other specific fire areas reveals an inconsistency with the plant Licensing | | Basis. The unit Licensing Basis takes credit for prevention of spurious | | operation of the PORVs by removing power from the valves prior to spurious | | operation. Current procedures require removing power from the PORVs but does | | not require removal of power prior to spurious operation. Spurious operation | | of the PORVs due to a hot short is an unanalyzed event. | | | | "Compensatory actions to minimize risk of fire in areas of concern are being | | implemented which include increased surveillances to verify operability of | | detection and suppression, control of transient combustibles and ignition | | sources. The PORVs are considered operable. | | | | "This event is being reported lAW 10CFR50.72(b)(3)(ii)(B) as an event or | | condition that results in the Nuclear Power Plant being in an unanalyzed | | condition that significantly degrades plant safety." | | | | The NRC Resident Inspector was notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38881 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: LASALLE REGION: 3 |NOTIFICATION DATE:04/27/2002 | | UNIT: [1] [2] [] STATE: IL |NOTIFICATION TIME:15:51[EDT] | | RXTYPE: [1] GE-5,[2] GE-5 |EVENT DATE: 04/27/2002 | +------------------------------------------------+EVENT TIME: 11:40[CDT] | | NRC NOTIFIED BY: GRANLUND |LAST UPDATE DATE: 04/27/2002 | | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |JOHN JACOBSON R3 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE NOTIFICATION WAS MADE OF A BOATING ACCIDENT ON THE LASALLE STATION | | COOLING LAKE | | | | | | On April 27, 2002, 1140 CDST the Main Control Room received a report from | | Outside Rounds Operator that a fishing boat had capsized on the station | | cooling lake, and two individuals aboard the capsized boat were at the | | Wastewater Treatment Facility after swimming ashore. One individual aboard | | the capsized boat remains missing. Currently the boat has been recovered, | | but after a search of the lake perimeter the individual remains missing. | | The Ottawa Search and Rescue Team was on site to perform rescue operations, | | but has determined that lake conditions are too rough to perform a water | | based rescue operation. State Police and LaSalle County Sheriff have been | | notified. Marseilles and Seneca Fire Departments are coming to the site to | | assist in a ground search. Department of Natural Resources officials are | | also assisting with the missing person search. | | | | | | The NRC Resident Inspector was notified. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021