Event Notification Report for April 18, 2002
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 04/17/2002 - 04/18/2002 ** EVENT NUMBERS ** 38856 38859 38862 +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 38856 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: MICHIGAN DEPT OF ENVIRONMENTAL QUAL |NOTIFICATION DATE: 04/15/2002| |LICENSEE: FORD MOTOR COMPANY |NOTIFICATION TIME: 16:00[EDT]| | CITY: DEARBORN REGION: 3 |EVENT DATE: 03/15/2002| | COUNTY: STATE: MI |EVENT TIME: [EDT]| |LICENSE#: AGREEMENT: N |LAST UPDATE DATE: 04/15/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |FRED BROWN NMSS | | |JOHN MADERA R3 | +------------------------------------------------+ | | NRC NOTIFIED BY: JOSEPH BONACCHI | | | HQ OPS OFFICER: RICH LAURA | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF POLONIUM-210 STATIC ELIMINATOR | | | | "This letter is pertinent to the lost of an anti-static air gun. The model | | number is P-2021. The serial number A2AW9S4 is on lease number 007136 and | | was shipped on 3/19/01. The device was used for spraying acrylic and also to | | prevent dust. The device was used in the Plastic Shop. It was last used | | during the month of August, 2001. To my knowledge, the device was misplaced | | or stolen. The efforts that was made was searching of the shop and | | questioning the shop personnel. This situation has been brought to | | management attention, The decision was made to not replace the anti-static | | gun." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38859 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PILGRIM REGION: 1 |NOTIFICATION DATE: 04/17/2002| | UNIT: [1] [] [] STATE: MA |NOTIFICATION TIME: 14:49[EDT]| | RXTYPE: [1] GE-3 |EVENT DATE: 04/17/2002| +------------------------------------------------+EVENT TIME: 13:30[EDT]| | NRC NOTIFIED BY: FRANCIS CLIFFORD |LAST UPDATE DATE: 04/17/2002| | HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |JOHN ROGGE R1 | |10 CFR SECTION: | | |ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF OFFSITE COMMUNICATIONS CAPABILITY VIA ALL EMERGENCY SIRENS DUE TO A | | LOW VOLTAGE CONDITION ON A CIRCUIT BOARD WHICH MAY HAVE RESULTED FROM AN | | ONGOING HEAT WAVE IN THE NORTHEAST | | | | A low voltage condition on a circuit board is believed to have resulted in | | the loss of offsite communication capability via the emergency sirens. | | Preliminary investigations revealed that the failure may have been heat | | related (the result of an ongoing heat wave in the northeast). | | Troubleshooting is currently in progress. | | | | The licensee notified all of the towns within the emergency planning zone, | | and the Fire Departments within the affected area plan to perform route | | alerts (make announcements locally) if there is a need to notify the public | | before the emergency sirens are returned to service. The licensee notified | | the NRC resident inspector but does not plan to issue a press release. | | | | ***** UPDATE FROM FRANCIS CLIFFORD TO LEIGH TROCINE AT 1546 ON 04/17/02 | | ***** | | | | The following text is a portion of a facsimile received from the licensee: | | | | "At 1330 on April 17, 2002, the Prompt Alert and Notification system | | (offsite communication capability - 112 sirens) was determined to be | | inoperable. This event was due to a failed siren that was broadcasting a | | continuous radio frequency transmission to the remaining sirens in the | | system. This condition prevented activation of the remaining 111 sirens. | | The Emergency Planning group is presently attempting to locate and isolate | | the problem. All affected towns have been notified of the loss of siren | | capability. A backup plan is in place (route alerting) in the event of an | | emergency at Pilgrim Station." | | | | "FOLLOWUP: At 1530 on April 17, 2002, the Prompt Alert and Notification | | system was restored to operable status. The failed siren has been isolated | | and will be repaired shortly. The remaining 111 sirens are operational. | | All affected towns have been notified that the system has been restored." | | | | "Notification References: 10CFR50.72(b)(1)(v) and 10CFR50.72(b)(3)(xiii)." | | | | The licensee plans to notify the NRC resident inspector and the Fire | | Departments. The NRC operations officer notified the R1DO (John Rogge). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38862 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: OYSTER CREEK REGION: 1 |NOTIFICATION DATE: 04/17/2002| | UNIT: [1] [] [] STATE: NJ |NOTIFICATION TIME: 16:46[EDT]| | RXTYPE: [1] GE-2 |EVENT DATE: 04/17/2002| +------------------------------------------------+EVENT TIME: 09:50[EDT]| | NRC NOTIFIED BY: GLENN HUTTON |LAST UPDATE DATE: 04/17/2002| | HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |JOHN ROGGE R1 | |10 CFR SECTION: | | |HFIT 26.73 FITNESS FOR DUTY | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | CONTRACT SUPERVISOR FITNESS-FOR-DUTY TEST POSITIVE FOR ALCOHOL | | | | A contract supervisor tested positive for alcohol and has been referred to | | the employee assistance program. (Contact the NRC operations officer for | | additional details.) | | | | The licensee notified the NRC resident inspector. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021