Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for November 26, 2001

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           11/23/2001 - 11/26/2001

                              ** EVENT NUMBERS **

38447  38513  38514  38515  
.
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38447       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FERMI                    REGION:  3  |NOTIFICATION DATE: 10/31/2001|
|    UNIT:  [2] [] []                 STATE:  MI |NOTIFICATION TIME: 14:55[EST]|
|   RXTYPE: [2] GE-4                             |EVENT DATE:        10/30/2001|
+------------------------------------------------+EVENT TIME:        19:00[EST]|
| NRC NOTIFIED BY:  D. COSEO                     |LAST UPDATE DATE:  11/23/2001|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ROGER LANKSBURY      R3      |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24-HOUR REPORT DUE TO VIOLATION OF LICENSE CONDITION                         |
|                                                                              |
| "On 10/30/2001 at 1900 hours, during a walkdown of approximately 600 fire    |
| barrier penetrations which had been mistakenly excluded from the Fermi 2     |
| fire barrier penetration seal inspection program, 11 penetrations were found |
| to have no seal material installed. To date, over 350 of the approximately   |
| 600 fire barrier penetrations not included in the program have been          |
| inspected. The lack of seal material in these penetrations constitutes an    |
| inoperable 10 CFR 50, Appendix R fire rated barrier and is reportable under  |
| License Condition 2.F as a violation of License Condition 2.C (9),           |
| 'Modifications for Fire Protection.' The plant is currently shut down for    |
| refueling. Hourly fire watches have been established in the affected areas   |
| as required by the Technical Requirements Manual. Detroit Edison will report |
| any further missing seals that are identified as part of this inspection."   |
|                                                                              |
| The NRC resident inspector has been informed of this report by the           |
| licensee.                                                                    |
|                                                                              |
| * * * UPDATE 11/23/01 AT 1805EST FROM KEVIN DAHM TO S. SANDIN * * *          |
|                                                                              |
| The licensee is retracting this report based on the following:               |
|                                                                              |
| "The 600 (approximately) fire barrier penetration seals which had been       |
| mistakenly excluded from the Fermi 2 fire barrier penetration seal           |
| inspection program have now all been inspected. Fifteen (15) of these        |
| penetrations were found to have not been sealed. These 15 penetrations are   |
| all in the same fire barrier. This fire barrier has been evaluated in        |
| accordance with Generic Letter 86-10, and it has been determined that the as |
| found configuration is adequate to ensure the capability to achieve and      |
| maintain safe shutdown in the event of a fire. Therefore, this condition     |
| does not constitute a violation of License Condition 2.C.(9) and is not      |
| reportable."                                                                 |
|                                                                              |
| The licensee informed the NRC Resident Inspector.  Notified R3DO(Lipa).      |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38513       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 11/23/2001|
|    UNIT:  [1] [] []                 STATE:  FL |NOTIFICATION TIME: 12:30[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        11/23/2001|
+------------------------------------------------+EVENT TIME:        12:10[EST]|
| NRC NOTIFIED BY:  CHARLIE PIKE                 |LAST UPDATE DATE:  11/23/2001|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO FLORIDA STATE INVOLVING RECOVERED SEA TURTLE
FROM    |
| UNIT 1 INTAKE STRUCTURE                                                      |
|                                                                              |
| "A sea turtle with no external injuries but appearing to be distressed was   |
| recovered from the Unit 1 Intake Structure.  The State Stranding Coordinator |
| for sea turtles has been contacted."                                         |
|                                                                              |
| * * * UPDATE 11/23/01 AT 1255EST FROM CHARLIE PIKE TO S. SANDIN * * *        |
|                                                                              |
| "Turtle has died."                                                           |
|                                                                              |
| The licensee informed both the State of Florida and the NRC Resident         |
| Inspector.                                                                   |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38514       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: OYSTER CREEK             REGION:  1  |NOTIFICATION DATE: 11/23/2001|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 19:38[EST]|
|   RXTYPE: [1] GE-2                             |EVENT DATE:        11/23/2001|
+------------------------------------------------+EVENT TIME:        18:00[EST]|
| NRC NOTIFIED BY:  GLENN HUTTON                 |LAST UPDATE DATE:  11/23/2001|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FITNESS FOR DUTY REPORT INVOLVING A LICENSED OPERATOR                        |
|                                                                              |
| A licensed employee was determined to be under the influence of alcohol      |
| during a random test.  The licensee took the employee home.  The licensee    |
| informed the NRC Resident Inspector.                                         |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38515       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COMANCHE PEAK            REGION:  4  |NOTIFICATION DATE: 11/24/2001|
|    UNIT:  [1] [2] []                STATE:  TX |NOTIFICATION TIME: 11:00[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        11/24/2001|
+------------------------------------------------+EVENT TIME:        03:30[CST]|
| NRC NOTIFIED BY:  LISA EDWARDS                 |LAST UPDATE DATE:  11/24/2001|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CHUCK CAIN           R4      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION REGARDING RELEASE OF NONRADIOACTIVE CHEMICALLY
TREATED  |
| WATER                                                                        |
|                                                                              |
| "During routine surveillance run of Fire Protection Pump X-05, the shutdown  |
| of the pump caused a momentary drop in system pressure resulting in the      |
| autostart of Fire Protection Pump X-04. The start of the second pump         |
| resulted in a momentary pressure surge that caused a pipe cap to separate    |
| releasing approximately 6,500 gallons of nonradioactive, chemically treated  |
| water to the environment and Squaw Creek Reservoir.                          |
|                                                                              |
| "Fire protection water is treated with Bulab 6002. This spill is reportable  |
| to the Texas Natural Resource Conservation Commission (TNRCC). TNRCC was     |
| notified at 0815 CST on 11/24/01.                                            |
|                                                                              |
| "Actions taken to contain/control the spill were adequate. Monitoring for    |
| fish kill is ongoing. No evidence of fish kill is evident to date."          |
|                                                                              |
| The NRC resident inspector has been informed of this event by the licensee.  |
+------------------------------------------------------------------------------+
.

Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021