Event Notification Report for July 6, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/05/2000 - 07/06/2000

                              ** EVENT NUMBERS **

37142  37143  37144  37145  37146  37147  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37142       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CLINTON                  REGION:  3  |NOTIFICATION DATE: 07/05/2000|
|    UNIT:  [1] [] []                 STATE:  IL |NOTIFICATION TIME: 13:01[EDT]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        07/05/2000|
+------------------------------------------------+EVENT TIME:        11:05[CDT]|
| NRC NOTIFIED BY:  FUNKHOUSER                   |LAST UPDATE DATE:  07/05/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MICHAEL JORDAN       R3      |
|10 CFR SECTION:                                 |                             |
|AMED 50.72(b)(2)(v)      OFFSITE MEDICAL        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POTENTIALLY CONTAMINATED PERSON TRANSPORTED TO THE HOSPITAL                  |
|                                                                              |
| "On 7/5/00 at 1105, a potentially contaminated worker was taken offsite by   |
| ambulance to John Warner Hospital in Clinton, Illinois. The worker, an       |
| Electrician, was working on the Fuel Building bridge on 755' Fuel Building   |
| when he passed out.  The Electrician was working in a potentially            |
| contaminated area.  Radiation Protection personnel accompanied the           |
| electrician to the hospital but were not able to verify that he was not      |
| contaminated at the time he left site to be taken to the hospital. The       |
| electrician regained consciousness while on the Fuel Building bridge. At     |
| 1132, Radiation Protection personnel frisked the electrician at the hospital |
| and found no contamination on the individual or his clothing. This           |
| notification is being made pursuant to 10CFR50.72(b)(2)(v), Offsite          |
| Medical."                                                                    |
|                                                                              |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37143       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 07/05/2000|
|    UNIT:  [1] [2] []                STATE:  MI |NOTIFICATION TIME: 13:06[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        07/05/2000|
+------------------------------------------------+EVENT TIME:        05:32[EDT]|
| NRC NOTIFIED BY:  COBB                         |LAST UPDATE DATE:  07/05/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MICHAEL JORDAN       R3      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|2     N          Y       98       Power Operation  |98       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POSITIVE FOR-CAUSE ALCOHOL TEST                                              |
|                                                                              |
| A contractor supervisor tested positive for alcohol during a for-cause test  |
| upon entering the site.  His access was suspended at 0930.                   |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37144       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: RIVER BEND               REGION:  4  |NOTIFICATION DATE: 07/05/2000|
|    UNIT:  [1] [] []                 STATE:  LA |NOTIFICATION TIME: 13:58[EDT]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        07/05/2000|
+------------------------------------------------+EVENT TIME:        09:20[CDT]|
| NRC NOTIFIED BY:  FELTNER                      |LAST UPDATE DATE:  07/05/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |DAVID GRAVES         R4      |
|10 CFR SECTION:                                 |                             |
|AESF 50.72(b)(2)(ii)     ESF ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR CORE COOLING SYSTEM ISOLATION DURING A SURVEILLANCE                  |
|                                                                              |
| "On 7/5/2000 at 0920 CDT, the Reactor Core Isolation Cooling (RCIC) System   |
| isolated due to a sensed high steam supply line differential pressure.       |
| Instrument technicians were performing required surveillance test            |
| STP-207-4248 on Division 1 pressure transmitter, E51-PDTN084A. This          |
| surveillance requires the transmitter to be hydraulically isolated from the  |
| system in order to perform a calibration and also generates a Division 1     |
| RCIC Isolation signal.                                                       |
|                                                                              |
| Per the plant design, the Division 1 and 2 pressure transmitters share a     |
| common sensing line.  While removing the Division 1 transmitter from         |
| service, the Division 2 transmitter, E51-PDTN084B, spiked high causing a     |
| Division 2 RCIC isolation signal and subsequent closure of E51-MOVF063, RCIC |
| Steam Supply Inboard Isolation Valve.                                        |
|                                                                              |
| Although the RCIC system was inoperable for scheduled maintenance at the     |
| time of the Division 2 isolation, the containment isolation function was     |
| still in service and considered operable. High Pressure Core Spray and all   |
| other ECCS systems remained operable while the RCIC system was isolated.     |
| RCIC will be returned to service following the completion of the scheduled   |
| maintenance activities.                                                      |
|                                                                              |
| The RCIC System Isolation Instrumentation is designated as an Engineered     |
| Safety Features system and this event is therefore reportable in accordance  |
| with 10CFR50.72."                                                            |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37145       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BEAVER VALLEY            REGION:  1  |NOTIFICATION DATE: 07/05/2000|
|    UNIT:  [1] [] []                 STATE:  PA |NOTIFICATION TIME: 14:17[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        07/05/2000|
+------------------------------------------------+EVENT TIME:        13:07[EDT]|
| NRC NOTIFIED BY:  MUELLER                      |LAST UPDATE DATE:  07/05/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |STEVEN DENNIS        R1      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(ii)     RPS ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       100      Power Operation  |0        Hot Standby      |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR TRIP FROM 100% POWER DUE TO TURBINE TRIP.                            |
|                                                                              |
| The plant had a reactor trip from 100% power due to a turbine trip.  Cause   |
| of the turbine trip is being investigated. All control rods fully inserted   |
| and no relief valves lifted or ECCS actuated.  The plant is stable in mode 3 |
| with RCS temperature and pressure at 547�F and 2235 Psig.  There were no     |
| radiological releases and no RCS or steam generator tube leaks.  All safety  |
| related equipment functioned as required and remains operable.  The aux feed |
| system started as expected and decay heat is being removed via the steam     |
| bypass system to the condenser.                                              |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37146       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MILLSTONE                REGION:  1  |NOTIFICATION DATE: 07/05/2000|
|    UNIT:  [] [] [3]                 STATE:  CT |NOTIFICATION TIME: 15:16[EDT]|
|   RXTYPE: [1] GE-3,[2] CE,[3] W-4-LP           |EVENT DATE:        07/05/2000|
+------------------------------------------------+EVENT TIME:        15:00[EDT]|
| NRC NOTIFIED BY:  LANGAN                       |LAST UPDATE DATE:  07/05/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |STEVEN DENNIS        R1      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|                                                   |                          |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CONTRACT EMPLOYEE FAILS FITNESS FOR DUTY TEST                                |
|                                                                              |
| A contractor employee failed a Fitness For Duty test administered on July 5, |
| 2000. Specific details of the event are not for public disclosure.           |
| Appropriate action has been taken accordance with the company Fitness For    |
| Duty program.                                                                |
|                                                                              |
|                                                                              |
| The NRC Resident Inspector will be notified.  State and Local agencies have  |
| been notified.                                                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37147       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HARRIS                   REGION:  2  |NOTIFICATION DATE: 07/05/2000|
|    UNIT:  [1] [] []                 STATE:  NC |NOTIFICATION TIME: 17:14[EDT]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        07/05/2000|
+------------------------------------------------+EVENT TIME:        10:35[EDT]|
| NRC NOTIFIED BY:  JERNIGAN                     |LAST UPDATE DATE:  07/05/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GEORGE BELISLE       R2      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| USE OF ILLEGAL CONTROLLED SUBSTANCE                                          |
|                                                                              |
| An employee was tested for cause for illegal controlled substance with the   |
| results being negative.  However, he admitted during the interview he had    |
| used such substance.                                                         |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+
