Event Notification Report for December 21, 1999
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 12/20/1999 - 12/21/1999 ** EVENT NUMBERS ** 36526 36527 36528 36529 +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 36526 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: U.S. ARMY |NOTIFICATION DATE: 12/20/1999| |LICENSEE: U.S.ARMY |NOTIFICATION TIME: 11:09[EST]| | CITY: Rock Island REGION: 3 |EVENT DATE: 12/10/1999| | COUNTY: STATE: IL |EVENT TIME: [CST]| |LICENSE#: 12-00722-06 AGREEMENT: Y |LAST UPDATE DATE: 12/20/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |THOMAS KOZAK R3 | | |BILL RULAND R1 | +------------------------------------------------+JOSIE PICCONE NMSS | | NRC NOTIFIED BY: JEFF HAVENER |FRANK CONGEL IRO | | HQ OPS OFFICER: LEIGH TROCINE | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | DISCOVERY OF A MISSING M-58 AIMING POST LIGHT SOURCE CONTAINING | | APPROXIMATELY 5 Ci OF TRITIUM | | | | On 12/10/99, the U.S. Army in Rock Island, Illinois, was notified that an | | M-58 aiming post light source was missing from a U.S. Army facility in Ft. | | Drum, New York. The missing source contained approximately 5 Ci of tritium, | | and the source had been removed from the aiming post light. Because there | | are typically no maintenance activities associated with aiming post lights, | | it is currently believed that the source was stolen. The source was | | discovered to be missing on approximately 12/06/99. | | | | (Call the NRC operations officer for licensee contact information.) | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 36527 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: KEWAUNEE REGION: 3 |NOTIFICATION DATE: 12/20/1999| | UNIT: [1] [] [] STATE: WI |NOTIFICATION TIME: 12:04[EST]| | RXTYPE: [1] W-2-LP |EVENT DATE: 12/20/1999| +------------------------------------------------+EVENT TIME: 07:10[CST]| | NRC NOTIFIED BY: MR. HUJET |LAST UPDATE DATE: 12/20/1999| | HQ OPS OFFICER: DOUG WEAVER +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |THOMAS KOZAK R3 | |10 CFR SECTION: | | |AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 97 Power Operation |97 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OUTSIDE DESIGN BASIS - BOTH TRAINS OF CONTROL ROOM AIR CONDITIONING | | INOPERABLE | | | | "At 0710 [CST], while attempting to rotate running equipment, the operator | | placed the control switch for the B Train control Room A/C to ON. | | Subsequently, the A Train switch was placed to OFF to allow the B Train to | | start. The B Train failed to start, and the A Train switch was placed back | | to AUTO. Further investigation determined that the A Train switch was | | placed to OFF greater than 20 seconds following the B switch being placed to | | ON. This resulted in a Trip signal being generated for the B Train unit. | | Therefore, both trains of Control Room A/C were out of service with the B | | Train Trip signal and the A Train switch in the OFF position. This | | condition existed for a total of 12 seconds before the A Train unit was | | restarted. The need to report this condition was not identified until 1025 | | [CST]." | | | | The licensee will inform the NRC resident inspector. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 36528 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: ARIZONA RADIATION REGULATORY AGENCY |NOTIFICATION DATE: 12/20/1999| |LICENSEE: ARIZONA STATE UNIVERSITY |NOTIFICATION TIME: 16:11[EST]| | CITY: TEMPE REGION: 4 |EVENT DATE: 12/16/1999| | COUNTY: STATE: AZ |EVENT TIME: 12:00[MST]| |LICENSE#: AZ 7-37 AGREEMENT: Y |LAST UPDATE DATE: 12/20/1999| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WILLIAM JOHNSON R4 | | |DR. COOL NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: AUBREY GODWIN | | | HQ OPS OFFICER: DOUG WEAVER | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT - LOST P32 | | | | "On December 16, 1999, the Agency was notified by the Licensee that a vial | | of P-32 labeled ATP was missing from the Department of Microbiology. The | | vial, the inner package, of a shipping container was placed in a storage | | freezer on November 17, 1999. The vial contained 0.5 millicuries on November | | 17, 1999. As of December 16, 1999, it contained 0.123 millicuries. An | | initial search by the Licensee failed to locate the missing vial or its | | contents. The initial search included surveys of the research laboratory in | | which the material was stored. The loss was detected on December 15, 1999, | | when a technician prepared to use the material. | | | | "ASU Department of Public Safety is investigating this incident. ... | | | | "The Agency is investigating the radiation safety issues. | | | | "The FBI and the U.S. Nuclear Regulatory Commission are being notified of | | this incident." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 36529 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 12/20/1999| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 19:38[EST]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 12/20/1999| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 15:45[EST]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 12/20/1999| | CITY: PIKETON REGION: 3 +-----------------------------+ | COUNTY: PIKE STATE: OH |PERSON ORGANIZATION | |LICENSE#: GDP-2 AGREEMENT: N |THOMAS KOZAK R3 | | DOCKET: 0707002 |JOHN SURMEIER NMSS | +------------------------------------------------+FRANK CONGEL IRO | | NRC NOTIFIED BY: DALE NOLE | | | HQ OPS OFFICER: DOUG WEAVER | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NCFR NON CFR REPORT REQMNT | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE NOTIFICATION TO DOE - MINOR OUT-GASSING OF UF6 WHILE SAMPLING | | CYLINDER | | | | ON 12/20/99, AT 1545 A DEPARTMENT OF ENERGY (DOE) OFF-NORMAL OCCURRENCE WAS | | INITIATED REGARDING A MINOR OUT-GASSING AT THE X-343 FEED VAPORIZATION AND | | SAMPLING FACILITY WHILE SAMPLING A DOE CYLINDER IN AUTOCLAVE SIX. RESPONSE | | PERSONNEL STOPPED THE OUT-GASSING AND STABILIZED THE CYLINDER FOR COOLDOWN. | | THIS EVENT IS REPORTABLE DUE TO NOTIFICATION BEING MADE TO AN OUTSIDE AGENCY | | (DOE). THE OUT-GASSING WAS DUE TO A CRACKED BONNET NUT ON THE CYLINDER | | VALVE. | | | | THE NRC RESIDENT INSPECTOR WILL BE INFORMED. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021