United States Nuclear Regulatory Commission - Protecting People and the Environment
Home > NRC Library > Document Collections > ACRS > Meeting Schedule and Related Documents > 1999 > Plant License Renewal Subcommittee Meeting

ACRS Plant License Renewal Subcommittee Meeting - June 30, 1999

ADVISORY COMMITTEE ON REACTOR SAFEGUARDS
PLANT LICENSE RENEWAL SUBCOMMITTEE MEETING
OCONEE APPLICATION
JUNE 30, 1999
ROCKVILLE, MARYLAND

- PROPOSED SCHEDULE -


TOPIC 						PRESENTER		 TIME



I.	Opening Remarks					M. Bonaca, ACRS		8:30-8:35 a.m.


II.  	Staff Introduction 				C. Grimes, NRR 		8:35-8:40 a.m.

III.	Topical Report BAW-2251, "Reactor Vessel"   	Duke Staff       	8:40-10:00 a.m.

     	A.  Appendix B: BAW-2275, Low Upper-Shelf
       	    Toughness
        B.  Appendix C: BAW-2274, Fracture Mechanics
        C.  Action Items


            ***BREAK***                                				10:00-10:15 a.m.


IV.   Topical Report BAW-2251 (Continued)		Duke Staff     		10:15-11:30 a.m.

V.    Final Safety Evaluation Related to  BAW-2251     	NRC Staff     		11:30-12:00 noon

            ***LUNCH***                             				12:00-1:00 p.m.

VI.   Status of License Renewal Activities  		NRC Staff         	1:00-1:45 p.m.

      A.  License Renewal Issues
      B.  Standard Format of Applications
      C.  Standard Review Plan, Regulatory Guide,
          and NEI 95-10

VII.  Overview of SER Related to Oconee License      	NRC Staff         	1:45-2:15 p.m.
      Renewal

      A.  Background
      B.  Organization of SER
      C.  Scoping and Screening Process (IPA)
      D.  Aging Management Programs
      E.  Time Limiting Aging Analyzes

            ***BREAK***                                    			2:15-2:30 p.m.


VIII.  Duke Energy Corporation Presentation         	Duke Staff        	2:30-3:30 p.m.



       A.  Background
       B.  License Renewal Application Scoping and
          Screening Process (IPA)
       C.  Aging Effects
       D.  Aging Management Programs
       E.  Time Limiting Aging Analyzes



IX.    SER Chap. 2.0 - Structures and Components      	NRC Staff         	3:30-3:55 p.m.
       Subject to an Aging Management Review


X.     SER Chap. 3.1 - Applicable Aging Effects for    	NRC Staff         	3:55-4:10 p.m.
       Mechanical Components



XI.    SER Chap. 3.2 - Common Aging Management        	NRC Staff         	4:10-4:30 p.m.
       Programs

XII.   Discussion                         		M. Bonaca, ACRS         4:30-5:30 p.m.

XIII.  Recess                                       	M. Bonaca, ACRS         5:30 p.m.


- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

ADVISORY COMMITTEE ON REACTOR SAFEGUARDS
PLANT LICENSE RENEWAL SUBCOMMITTEE MEETING
OCONEE APPLICATION
JULY 1, 1999
ROCKVILLE, MARYLAND

- PROPOSED SCHEDULE -


TOPIC						PRESENTER		TIME

I.   Opening Remarks     				M. Bonaca, ACRS        	8:30-8:35 a.m.

II.  SER Chap. 3.3 - Containment Structures  		NRC Staff      		8:35-9:00 a.m.

III. SER Chap. 3.4 - Reactor Coolant System  		NRC Staff      		9:00-9:20 a.m.

IV.  SER Chap. 3.5 - Engineered Safety Features		NRC Staff      		9:20-9:40 a.m.
     Systems

V.   SER Chap. 3.6  - Auxiliary Systems 		NRC Staff     		9:40-10:00 a.m.

     		***BREAK***          						10:00-10:15 a.m.

VI.  SER Chap. 3.7: Steam and Power Conversion		NRC Staff   		10:15-10:35 a.m.
     Systems

VII. SER Chap. 3.8: Structures and Component 		NRC Staff   		10:35-11:00 a.m.
     Support

VIII. SER Chap. 3.9: Electrical Components    		NRC Staff   		11:00-11:20 a.m.

IX.  SER Chap. 4.0: Time-Limited Aging Analyses   	NRC Staff   		11:20-11:40 a.m.

X.   Subcommittee Discussion  				M. Bonaca, ACRS  	11:40-12:00 noon

     A.   Presentations for the September 1-3, 1999
          ACRS Full Committee Meeting

     B.   Topics for ACRS Interim Letter

          	***LUNCH***           						12:00-1:00 p.m.



XI.  Options For Crediting Existing Programs 		NRC Staff      		1:00-2:00 p.m.



XII. Crediting Existing Programs 	  		NEI       		2:00-2:45 p.m.

     		***BREAK***             					2:45-3:00 a.m.


XIII.Subcommittee Discussion  				M. Bonaca, ACRS   	3:00-4:00 p.m.

          A.   Presentations for the July 14, 1999
               ACRS Full Committee Meeting
          B.   Topics for ACRS Letter
          C.   Additional Staff Presentations
          D.   Future Meetings

XIV. Adjourn        					M. Bonaca, ACRS          4:00 p.m.



NOTE:     Presentation time should not exceed 50 percent of the total time allocated for
          specific item.  The remaining 50 percent of the time is reserved for discussion.

          Number of copies of the presentation materials to be provided to the ACRS - 25.



CONTACT: N. Dudley NFD@NRC.GOV ACRS Senior Staff Engineer



Page Last Reviewed/Updated Monday, June 04, 2018