Skip to main content

Power Reactor Status Report for March 05, 2015

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Beaver Valley 1 100
Beaver Valley 2 100
Calvert Cliffs 1 100
Calvert Cliffs 2 0 2015-02-15 REFUELING OUTAGE *
FitzPatrick 100
Ginna 100
Hope Creek 1 100
Indian Point 2 100
Indian Point 3 0 2015-03-01 REFUELING OUTAGE
Limerick 1 100
Limerick 2 93 COASTDOWN TO REFUELING OUTAGE
Millstone 2 100
Millstone 3 100
Nine Mile Point 1 93 COASTDOWN TO REFUELING OUTAGE *
Nine Mile Point 2 100
Oyster Creek 100
Peach Bottom 2 89 HOLDING POWER FOR EPU TESTING
Peach Bottom 3 100
Pilgrim 1 100
Salem 1 100
Salem 2 100
Seabrook 1 100
Susquehanna 1 100
Susquehanna 2 100
Three Mile Island 1 100

Region 2

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Browns Ferry 1 100 CONSERVATIVE OPERATIONS ALERT AND EXTREME WEATHER ALERT DUE TO ICING CONDITIONS *
Browns Ferry 2 95 DRYWELL INLEAKAGE ISSUE VIA RBCCW SYSTEM -CONSERVATIVE OPERATIONS ALERT AND EXTREME WEATHER ALERT DUE TO ICING CONDITIONS *
Browns Ferry 3 100 CONSERVATIVE OPERATIONS ALERT AND EXTREME WEATHER ALERT DUE TO ICING CONDITIONS *
Brunswick 1 100
Brunswick 2 0 2015-02-20 DEFUELED
Catawba 1 100
Catawba 2 0 2015-02-27 REFUELING OUTAGE
Farley 1 100
Farley 2 100
Harris 1 100
Hatch 1 100
Hatch 2 0 2015-02-09 REFUELING OUTAGE *
McGuire 1 100
McGuire 2 100
North Anna 1 90 HOLDING POWER UNTIL REFUELING OUTAGE WINDOW - COASTDOWN TO REFUELING OUTAGE
North Anna 2 100
Oconee 1 100
Oconee 2 100
Oconee 3 100
Robinson 2 100
Saint Lucie 1 100
Saint Lucie 2 100
Sequoyah 1 100 CONSERVATIVE OPERATIONS ALERT IN EFFECT
Sequoyah 2 0 2015-03-02 REACTOR TRIP - SEE EN # 50856 - CONSERVATIVE OPERATIONS ALERT IN EFFECT
Summer 100
Surry 1 100
Surry 2 100
Turkey Point 3 49 MAIN TURBINE VALVE TESTING *
Turkey Point 4 100
Vogtle 1 100
Vogtle 2 100
Watts Bar 1 100 CONSERVATIVE OPERATIONS ALERT DUE TO ICING CONDITIONS *

Region 3

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Braidwood 1 100
Braidwood 2 100
Byron 1 0 2015-03-03 REACTOR TRIP - SEE EN# 50859
Byron 2 100
Clinton 99 100% ELECTRICAL CAPABILITY
D.C. Cook 1 100
D.C. Cook 2 100
Davis-Besse 100
Dresden 2 100
Dresden 3 100
Duane Arnold 100
Fermi 2 100
La Salle 1 100 COLD WEATHER ALERT IN EFFECT *
La Salle 2 21 MAIN GENERATOR TIED TO GRID - HOLDING FOR JET PUMP FME ISSUE - COLD WEATHER ALERT IN EFFECT *
Monticello 95 EPU TESTING IN PROGRESS
Palisades 100
Perry 1 86 COASTDOWN TO REFUELING OUTAGE *
Point Beach 1 100
Point Beach 2 98 REDUCED POWER FOR SCHEDULED TESTING *
Prairie Island 1 100
Prairie Island 2 100 REDUCING POWER SLOWLY FOR CONTROLLED SHUTDOWN TO ENTER FORCED OUTAGE DUE TO LOSS OF INSTRUMENT AIR *
Quad Cities 1 0 2015-03-02 REFUELING OUTAGE - COLD WEATHER ALERT IN EFFECT *
Quad Cities 2 100 COLD WEATHER ALERT IN EFFECT *

Region 4

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Arkansas Nuclear 1 100
Arkansas Nuclear 2 100
Callaway 100
Columbia Generating Station 100
Comanche Peak 1 100 COLD WEATHER ALERT IN EFFECT *
Comanche Peak 2 100 COLD WEATHER ALERT IN EFFECT *
Cooper 100
Diablo Canyon 1 100
Diablo Canyon 2 100
Fort Calhoun 100
Grand Gulf 1 100
Palo Verde 1 100
Palo Verde 2 100
Palo Verde 3 100
River Bend 1 0 2015-02-22 REFUELING OUTAGE
South Texas 1 100
South Texas 2 100
Waterford 3 100
Wolf Creek 1 0 2015-02-28 REFUELING OUTAGE *

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.