Skip to main content

Power Reactor Status Report for November 05, 2011

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Beaver Valley 1 99 *
Beaver Valley 2 100
Calvert Cliffs 1 100
Calvert Cliffs 2 100
FitzPatrick 100
Ginna 100
Hope Creek 1 100
Indian Point 2 100
Indian Point 3 100 138/13.8KV FEEDER #95891 DEENERGIZED FOR MAINTENANCE
Limerick 1 100
Limerick 2 100
Millstone 2 100
Millstone 3 0 2011-10-08 REFUELING OUTAGE
Nine Mile Point 1 100
Nine Mile Point 2 100
Oyster Creek 100
Peach Bottom 2 100
Peach Bottom 3 100
Pilgrim 1 100
Salem 1 0 2011-10-23 DEFUELED
Salem 2 100
Seabrook 1 100 CONTINGENCY MLCC2
Susquehanna 1 99 *
Susquehanna 2 80 1% /HOUR RAMP UP FOLLOWING ROD SEQUENCE EXCHANGE *
Three Mile Island 1 0 2011-10-24 DEFUELED
Vermont Yankee 60 HOLDING POWER FOR REACTOR ENGINEERING TESTS *

Region 2

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Browns Ferry 1 76 HOLDING FOR SCRAM TIME TESTING AND ROD SEQUENCE EXCHANGE TRINITY 161 KV LINE OOS *
Browns Ferry 2 100 TRINITY 161 KV LINE OOS
Browns Ferry 3 100 TRINITY 161 KV LINE OOS
Brunswick 1 100
Brunswick 2 0 2011-11-04 MAINTENANCE OUTAGE *
Catawba 1 100
Catawba 2 100
Crystal River 3 0 2009-09-25 DEFUELED; CONTAINMENT TENSIONING ON HOLD
Farley 1 100
Farley 2 0 2011-10-09 REFUELING OUTAGE
Harris 1 100
Hatch 1 99 *
Hatch 2 100
McGuire 1 100
McGuire 2 100
North Anna 1 0 2011-08-23 FORCED OUTAGE
North Anna 2 0 2011-08-23 REFUELING OUTAGE
Oconee 1 100
Oconee 2 0 2011-10-21 DEFUELED
Oconee 3 100
Robinson 2 100
Saint Lucie 1 85 REDUCED POWER DUE TO 1A1 CIRC WATER PUMP OOS - COMMENCED DILUTION TO BEGIN COASTDOWN
Saint Lucie 2 100
Sequoyah 1 100
Sequoyah 2 100
Summer 100
Surry 1 100
Surry 2 75 REDUCED POWER TO REPLACE MOTOR ON HEATER DRAIN PUMP
Turkey Point 3 100
Turkey Point 4 100
Vogtle 1 100
Vogtle 2 100
Watts Bar 1 100

Region 3

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Braidwood 1 100
Braidwood 2 100
Byron 1 99 FEEDWATER INSTRUMENT FLOW UNCERTAINTY
Byron 2 96 REDUCED FOR FEEDWATER HEATER MAINTENANCE *
Clinton 97 100% ELECTRICAL CAPABILITY
D.C. Cook 1 100
D.C. Cook 2 100
Davis-Besse 0 2011-09-30 MAINTENANCE OUTAGE - REACTOR VESSEL HEAD REPLACEMENT *
Dresden 2 0 2011-10-16 REFUELING OUTAGE
Dresden 3 100
Duane Arnold 100
Fermi 2 100
Kewaunee 100
La Salle 1 100
La Salle 2 100
Monticello 100
Palisades 100
Perry 1 100 *
Point Beach 1 0 2011-10-02 REFUELING OUTAGE *
Point Beach 2 100
Prairie Island 1 100
Prairie Island 2 100
Quad Cities 1 100
Quad Cities 2 100

Region 4

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Arkansas Nuclear 1 0 2011-10-16 REFUELING OUTAGE - CORE RELOAD IN PROGRESS
Arkansas Nuclear 2 100
Callaway 0 2011-10-15 DEFUELED
Columbia Generating Station 100
Comanche Peak 1 100
Comanche Peak 2 100
Cooper 100
Diablo Canyon 1 100
Diablo Canyon 2 100
Fort Calhoun 0 2011-04-09 REFUELING OUTAGE
Grand Gulf 1 96 2ND STAGE MSR LIMITED TO 96% POWER
Palo Verde 1 0 2011-10-07 REFUELING OUTAGE
Palo Verde 2 100
Palo Verde 3 100
River Bend 1 100
San Onofre 2 100
San Onofre 3 100
South Texas 1 100
South Texas 2 0 2011-10-29 REFUELING OUTAGE
Waterford 3 100
Wolf Creek 1 90 REDUCED POWER TO TROUBLESHOOT PROBLEM FOUND DURING TURBINE STOP VALVE TESTING *

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.