Skip to main content

Power Reactor Status Report for April 26, 2001

UNEVALUATED INFORMATION PROVIDED BY THE FACILITY

On this page:

Region 1

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Beaver Valley 1 0 2001-04-20 MAINTENANCE OUTAGE
Beaver Valley 2 100
Calvert Cliffs 1 100
Calvert Cliffs 2 0 2001-03-16 REFUELING OUTAGE *
FitzPatrick 100
Ginna 100
Hope Creek 1 100
Indian Point 2 100
Indian Point 3 98 COASTDOWN TO REFUELING OUTAGE *
Limerick 1 100
Limerick 2 100
Millstone 2 97 CIRCULATING WATER BAY MAINTENANCE
Millstone 3 100
Nine Mile Point 1 0 2001-03-18 REFUELING OUTAGE
Nine Mile Point 2 95 HOLDING DUE TO RECIRC FLOW CONTROL VALVE PROBLEM
Oyster Creek 100
Peach Bottom 2 100
Peach Bottom 3 100
Pilgrim 1 0 2001-04-21 REFUELING OUTAGE
Salem 1 0 2001-04-06 REFUELING OUTAGE - DEFUELED
Salem 2 100
Seabrook 1 100
Susquehanna 1 100
Susquehanna 2 38 CONTROL ROD TESTING *
Three Mile Island 1 75 MAIN XMFR GAS INCREASE *
Vermont Yankee 99 COASTDOWN TO REFUELING OUTAGE *

Region 2

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Browns Ferry 1 0 1985-03-03 DEFUELED
Browns Ferry 2 20 TURBINE OFFLINE DUE TO HIGH VIBRATION
Browns Ferry 3 100
Brunswick 1 100
Brunswick 2 100
Catawba 1 100
Catawba 2 100
Crystal River 3 100
Farley 1 100
Farley 2 0 2001-02-24 REFUELING OUTAGE
Harris 1 100
Hatch 1 100 *
Hatch 2 100
McGuire 1 100
McGuire 2 100
North Anna 1 100
North Anna 2 100
Oconee 1 100
Oconee 2 0 2001-04-25 REFUELING OUTAGE *
Oconee 3 100 *
Robinson 2 0 2001-04-06 REFUELING OUTAGE - DEFUELED
Saint Lucie 1 0 2001-04-02 REFUELING OUTAGE *
Saint Lucie 2 100
Sequoyah 1 100
Sequoyah 2 100
Summer 100
Surry 1 100
Surry 2 100
Turkey Point 3 100
Turkey Point 4 100
Vogtle 1 100
Vogtle 2 0 2001-04-07 REFUELING OUTAGE
Watts Bar 1 100

Region 3

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Braidwood 1 100 *
Braidwood 2 100
Byron 1 100 *
Byron 2 100
Clinton 100
D.C. Cook 1 100
D.C. Cook 2 100
Davis-Besse 100
Dresden 2 100
Dresden 3 100
Duane Arnold 0 2001-04-12 REFUELING OUTAGE
Fermi 2 100
Kewaunee 96 MAXIMUM POWER LEVEL DUE TO PLUGGED STEAM GENERATOR TUBES
La Salle 1 100
La Salle 2 100
Monticello 100
Palisades 0 2001-03-30 REFUELING OUTAGE
Perry 1 100
Point Beach 1 0 2001-04-06 REFUELING OUTAGE - DEFUELED
Point Beach 2 100
Prairie Island 1 100
Prairie Island 2 100
Quad Cities 1 100
Quad Cities 2 100

Region 4

Unit Power Down Reason or Comment Change in Report (*) Scrams (#)
Arkansas Nuclear 1 100
Arkansas Nuclear 2 100
Callaway 0 2001-04-06 REFUELING OUTAGE
Columbia Generating Station 91 COASTDOWN TO REFUELING OUTAGE
Comanche Peak 1 80 FLUX MAPPING *
Comanche Peak 2 100
Cooper 100
Diablo Canyon 1 100
Diablo Canyon 2 100
Fort Calhoun 0 2001-03-15 REFUELING OUTAGE HEATUP IN PROGRESS *
Grand Gulf 1 0 2001-04-13 REFUELING OUTAGE
Palo Verde 1 0 2001-03-31 REFUELING OUTAGE - DEFUELED
Palo Verde 2 99
Palo Verde 3 99
River Bend 1 76 CONTROL ROD PATTERN ADJUSTMENT *
San Onofre 2 100
San Onofre 3 0 2001-02-03 MAINTENANCE OUTAGE
South Texas 1 100
South Texas 2 100
Waterford 3 100
Wolf Creek 1 100

* - Power Reactor Status Report change within past 24 hours
# - Number of reactor scrams or trips within past 24 hours

Notes:
  • Reactor status data collected between 4 a.m. and 8 a.m. each day.
  • All times are based on eastern time.