Skip to main content

Event Notification Report for November 23, 2026

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/22/2026 - 11/23/2026

EVENT NUMBERS
58532585335853458542585375854658547

Agreement State
Event Number: 58532
Rep Org: Arizona Dept of Health Services
Licensee: Integer Consulting, LLC
Region: 4
City: Gilbert   State: AZ
County:
License #: 07-706
Agreement: Y
Docket:
NRC Notified By: Brian D. Goretzki
HQ OPS Officer: Adam Conklin
Notification Date: 11/13/2026
Notification Time: 12:43 [ET]
Event Date: 11/12/2026
Event Time: 00:00 [MST]
Last Update Date: 11/13/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - FOUND SOURCE

The following information was provided by the Arizona Department of Health Services (the Department) via email:

"On November 12, 2026, the Department received a phone call from a contractor that a Troxler model 3450 nuclear moisture density gauge was found off the Interstate 10 and Loop 101 interchange. An inspector responded to the site to retrieve the gauge and transported it back to the [Department]. The Department is in possession of the nuclear gauge and is currently performing leak testing of the device. The gauge contains 8 millicuries of Cs-137 and 40 millicuries of Am-241. The Department has requested additional information and continues to investigate the event.

"Additional information will be provided as it is received in accordance with SA-300."

Arizona incident number: 26-066

THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Agreement State
Event Number: 58533
Rep Org: Louisiana Dept of Environ Quality
Licensee: Touro Infirmary
Region: 4
City: New Orleans   State: LA
County:
License #: LA-1198-L01
Agreement: Y
Docket:
NRC Notified By: James Pate
HQ OPS Officer: Adam Conklin
Notification Date: 11/13/2026
Notification Time: 13:32 [ET]
Event Date: 11/11/2026
Event Time: 00:00 [CST]
Last Update Date: 11/13/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - LEAKING SOURCE

The following information was provided by the Louisiana Department of Environmental Quality (LDEQ) via email:

"On November 11, 2026, the licensee contacted the LDEQ concerning a leaking vial source, which was wipe tested on October 15, 2026. The cesium-137 vial source had an activity of 112 microcuries and the removable activity was 21.6 nanocuries.

"The serial number for the vial is CK957, manufacturer: Amersham, model: CDC.V1, and assay date was December 6, 1991, with an initial activity of 250 microcuries.

"There was no contamination event.

"The licensee's radiation safety officer stated that the vial source will be sealed and shipped to a nuclear pharmacy for disposal to correct this situation."

Louisiana incident number: LA20260014


Agreement State
Event Number: 58534
Rep Org: Tennessee Div Radiological Health
Licensee: Johnson City Medical Center
Region: 1
City: Johnson City   State: TN
County:
License #: R-90004
Agreement: Y
Docket:
NRC Notified By: Andrew Holcomb
HQ OPS Officer: Ian Howard
Notification Date: 11/13/2026
Notification Time: 16:23 [ET]
Event Date: 10/03/2026
Event Time: 12:00 [EST]
Last Update Date: 11/13/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following information was provided by the Tennessee Division of Radiological Health (the Department) via email:

"The Department was informed on November 13, 2026, of dose numbers that constituted an underdose to a patient. Contact from the licensee was made on November 9, 2026, but the dose data was not received until November 13, 2026. The physician prescribed a two-treatment fraction of BWXT Y-90 TheraSpheres. The first fraction was successfully delivered, but during the second treatment a kink occurred in the catheter. No spillage or contamination was found. It was estimated that approximately 2 mCi of a planned 23.5 mCi was delivered. The physician confirmed that the patient was informed on the day of the treatment. The post-treatment plan showed an underdose difference of 35,850 rem between the planned 393.5 Gy (39,350 rem) and the delivered 35.0 Gy (3,500 rem). The physician decided against a repeat treatment."

Tennessee Event Report ID Number: TN-26-086

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Fuel Cycle Facility
Event Number: 58542
Facility: Louisiana Energy Services
Region: 2     State: NM
Unit: [] [] []
RX Type:
Comments: Uranium Enrichment Facility
Gas Centrifuge Facility

NRC Notified By: Lindsey Zimmerman
HQ OPS Officer: Josue Ramirez
Notification Date: 11/19/2026
Notification Time: 09:59 [ET]
Event Date: 11/18/2026
Event Time: 10:45 [MST]
Last Update Date: 11/19/2026
Emergency Class: Non Emergency
10 CFR Section:
PART 70 APP A (b)(2) - Loss Or Degraded Safety Items
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Peterka, Nicholas (NMSS)
Event Text
DEGRADATION OF ITEM RELIED ON FOR SAFETY

The following information was provided by the licensee via phone and email:

"The facility is in a safe and stable configuration and no accident has occurred.

"During annual routine maintenance of a tails cylinder station, the surveillance to verify 'IROFS2', a thermocouple for preventing overheating of a cylinder, failed to trip at the required setpoint temperature. The cylinder station was tagged out of service prior to maintenance to ensure no material was present during testing. 'IROFS1' for this station, which provides similar protection, passed the surveillance. The affected thermocouple is located in a tails cylinder station within SBM 1001.

"Corrective actions have begun. A detailed investigation will be conducted. The station will remain out of service until repairs and retesting of 'IROFS2' occurs."


Agreement State
Event Number: 58537
Rep Org: Kentucky Dept for Public Health
Licensee: Baptist Health Louisville
Region: 1
City: Louisville   State: KY
County:
License #: 202-117-27
Agreement: Y
Docket:
NRC Notified By: Russell Hestand
HQ OPS Officer: Ian Howard
Notification Date: 11/14/2026
Notification Time: 15:34 [ET]
Event Date: 11/13/2026
Event Time: 11:10 [CST]
Last Update Date: 11/14/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
Silberfeld, Dafna (NMSS)
NMSS_Events_Notification, (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following is a summary of information provided by the Radiation Health Branch (RHB) of the Kentucky Department for Public Health and Safety via email:

"On November 14, 2026, at 1422 CST, the radiation safety officer at Baptist Health Louisville reported a misadministration to RHB. The technologist administered the wrong radiopharmaceutical/radionuclide to a patient. The patient was to be injected with Tc-99m sestamibi for a parathyroid scan. The patient was instead injected with 22 mCi of Tc99m methyl diphosphonate. The patient was unable to get the exam they came in for. The patient and authorized user were informed, and the study was rescheduled later. The ordering physician was notified as well. There were no safety concerns for the patient. They are working on the proper reports and corrective actions."

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Power Reactor
Event Number: 58546
Facility: Salem
Region: 1     State: NJ
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Steven Boesch
HQ OPS Officer: Josue Ramirez
Notification Date: 11/20/2026
Notification Time: 15:10 [ET]
Event Date: 11/20/2026
Event Time: 09:10 [EST]
Last Update Date: 11/20/2026
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
R1_Reactor_Event (EMAIL)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Defueled 0 Defueled
2 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY EVENT

The following information was provided by the licensee via phone and email:

"On November 20, 2026, at 0910 EST, a licensed operator was determined to have violated the fitness-for-duty (FFD) policy. The individual's unescorted access has been revoked. This notification is being made under 10 CFR 26.719 (b) (2) (ii) for a significant FFD policy violation.
"The NRC Resident Inspector and New Jersey Bureau of Nuclear Engineering have been notified."



Power Reactor
Event Number: 58547
Facility: Ginna
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: Sean Gillen
HQ OPS Officer: Robert A. Thompson
Notification Date: 11/22/2026
Notification Time: 10:07 [ET]
Event Date: 11/22/2026
Event Time: 09:22 [EST]
Last Update Date: 11/22/2026
Emergency Class: Non Emergency
10 CFR Section:
26.719 - Fitness For Duty
Person (Organization):
R1 Reactor Events, (EMAIL)
FFD Group, (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY

The following information was provided by the licensee via phone and email:

"At 0922 EST on 11/22/2026, it was determined that a non-licensed supervisor failed a test specified by the fitness for duty testing program. The individual's authorization for site access has been terminated at all Constellation facilities.

"The NRC Resident Inspector has been notified."