Event Notification Report for November 17, 2026
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
11/16/2026 - 11/17/2026
EVENT NUMBERS
58527
Agreement State
Event Number: 58527
Rep Org: Pennsylvania Dept of Environ Prot
Licensee: David Blackmore & Associate, Inc.
Region: 1
City: Philadelpia State: PA
County:
License #: PA-1289
Agreement: Y
Docket:
NRC Notified By: John S Chipo
HQ OPS Officer: Ernest West
Licensee: David Blackmore & Associate, Inc.
Region: 1
City: Philadelpia State: PA
County:
License #: PA-1289
Agreement: Y
Docket:
NRC Notified By: John S Chipo
HQ OPS Officer: Ernest West
Notification Date: 11/10/2026
Notification Time: 12:29 [ET]
Event Date: 11/09/2026
Event Time: 00:00 [EST]
Last Update Date: 11/16/2026
Notification Time: 12:29 [ET]
Event Date: 11/09/2026
Event Time: 00:00 [EST]
Last Update Date: 11/16/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
CNSC (Canada), (EMAIL)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB, (EMAIL)
CNSC (Canada), (EMAIL)
AGREEMENT STATE REPORT - STOLEN GAUGE
The following is a summary of information provided by the Pennsylvania Department of Health, Bureau of Environmental Health and Radiation Protection (the Department) via email:
On November 10, 2026, an employee of the licensee reported to the police that their vehicle was stolen overnight with a nuclear density gauge inside. The Department is in contact with the licensee and will provide updates as additional information becomes available.
Manufacturer: CPN International Division of InstroTek, Inc.
Model: MC Series PORTAPROBE (MC-1)
Serial number: MD20506599
Isotopes and activities: 10 millicuries (mCi) of cesium-137 (Cs-137) and 50 mCi of americium-241/beryllium (Am-241:Be)
Pennsylvania Incident Number: PA 260021
* * * UPDATE ON 11/16/2026 AT 1135 EST FROM JOHN CHIPPO TO ADAM CONKLIN * * *
The following information was provided by the Pennsylvania Department of Health, Bureau of Environmental Health and Radiation Protection (the Department) via email:
"On November 16, 2026, a nuclear density gauge was discovered in Philadelphia. The discovery was reported to the Philadelphia Office of Emergency Management. The Philadelphia Fire Department Hazardous Materials Administrative Unit (PFD HMAU) responded to the scene. The Department spoke to a PFD HMAU officer and was able to verify that the serial number on the gauge matches the serial number of the gauge that was in the stolen vehicle. The licensee will coordinate with PFD HMAU to retrieve the gauge.
"The Department will perform a reactive inspection. More information will be provided upon receipt."
Notified NMSS Events Notifications, ILTAB, CNSC (Canada) via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf
The following is a summary of information provided by the Pennsylvania Department of Health, Bureau of Environmental Health and Radiation Protection (the Department) via email:
On November 10, 2026, an employee of the licensee reported to the police that their vehicle was stolen overnight with a nuclear density gauge inside. The Department is in contact with the licensee and will provide updates as additional information becomes available.
Manufacturer: CPN International Division of InstroTek, Inc.
Model: MC Series PORTAPROBE (MC-1)
Serial number: MD20506599
Isotopes and activities: 10 millicuries (mCi) of cesium-137 (Cs-137) and 50 mCi of americium-241/beryllium (Am-241:Be)
Pennsylvania Incident Number: PA 260021
* * * UPDATE ON 11/16/2026 AT 1135 EST FROM JOHN CHIPPO TO ADAM CONKLIN * * *
The following information was provided by the Pennsylvania Department of Health, Bureau of Environmental Health and Radiation Protection (the Department) via email:
"On November 16, 2026, a nuclear density gauge was discovered in Philadelphia. The discovery was reported to the Philadelphia Office of Emergency Management. The Philadelphia Fire Department Hazardous Materials Administrative Unit (PFD HMAU) responded to the scene. The Department spoke to a PFD HMAU officer and was able to verify that the serial number on the gauge matches the serial number of the gauge that was in the stolen vehicle. The licensee will coordinate with PFD HMAU to retrieve the gauge.
"The Department will perform a reactive inspection. More information will be provided upon receipt."
Notified NMSS Events Notifications, ILTAB, CNSC (Canada) via email.
THIS MATERIAL EVENT CONTAINS A 'Less than Cat 3' LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf