Skip to main content

Event Notification Report for November 02, 2026

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/01/2026 - 11/02/2026

EVENT NUMBERS
585055851058514

Agreement State
Event Number: 58505
Rep Org: Alabama Dept of Public Health
Licensee: Auburn University
Region: 1
City: Auburn   State: AL
County:
License #: 248
Agreement: Y
Docket:
NRC Notified By: Sean Williams
HQ OPS Officer: Philip Alier
Notification Date: 10/23/2026
Notification Time: 13:36 [ET]
Event Date: 10/21/2026
Event Time: 00:00 [CDT]
Last Update Date: 10/23/2026
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - FAILED LEAK TEST

The following information was provided by the Radioactive Material Compliance Branch of the Alabama Department of Public Health via email:

"On October 21, 2026, the licensee reported that one of their electron capture detector (ECD) sources failed a leak test in preparation for disposal. The ECD source is an Eckert and Ziegler Ni-63 source with a 10 mCi activity and an assay date of January 1, 2026. The source model number is GL1318, and the serial number is SS2197. The device it was removed from is a Shimadzu GC-2104 with a serial number of C11485014099SA. After it was determined that the sealed source was leaking, the Shimadzu GC-2014 and the area were wiped, and no removable contamination was detected. The Ni-63 sealed source was placed in Auburn University's radiological waste area and is awaiting pickup by a commercial waste vendor."

Alabama incident number: 26-018


Power Reactor
Event Number: 58510
Facility: Palisades
Region: 3     State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: Kyle Steffic
HQ OPS Officer: Christopher Prescott
Notification Date: 10/30/2026
Notification Time: 11:38 [ET]
Event Date: 09/06/2026
Event Time: 02:54 [EDT]
Last Update Date: 10/30/2026
Emergency Class: Non Emergency
10 CFR Section:
50.73(a)(1) - Invalid Specif System Actuation
Person (Organization):
Nguyen, April (R3 BC)
R3 Reactor Events (Email)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
INVALID SPECIFIED SYSTEM ACTUATION

The following information was provided by the licensee via phone and email:

"At 0254 EDT, on September 6, 2026, operations received a containment isolation signal from the 'right' train fuel handling area radiation monitor (RIA-2317). At 0256 EDT, operations entered AOP-31, Spurious Containment Isolation, and performed the required abnormal operating procedure actions. All 'right' train valves actuated as designed.

"Radiation protection performed surveys of the general area of the 649' [elevation] of containment around the refuel monitors, and dose rates were normal. It was found that RIA-2317 had spiked high and isolated containment as designed. The monitor reading continued to rise and did not stabilize at the expected dose rates.

"RIA-2317 was determined to be inoperable and actions were taken to restore the system."

The NRC Resident Inspector was notified.


Power Reactor
Event Number: 58514
Facility: Cooper
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: Aric Harris
HQ OPS Officer: Robert A. Thompson
Notification Date: 11/01/2026
Notification Time: 09:20 [ET]
Event Date: 11/01/2026
Event Time: 04:54 [CST]
Last Update Date: 11/01/2026
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS Actuation - Critical
Person (Organization):
Dodson, Doug (R4 BC)
R4_Reactor_Events (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R Y 9 Startup 0 Hot Shutdown
Event Text
MANUAL REACTOR SCRAM

The following information was provided by the licensee via phone and email:

"On November 1, 2026, at 0454 CST, with the unit in Mode 2, [startup], at 9 percent power [starting up following a refueling outage], the reactor was manually tripped due to elevated vibrations on the only feedwater pump in service. The trip was not complex, with all systems responding normally post-trip.

"Operations stabilized the plant [in Mode 3, hot shutdown]. Reactor water lever is being maintained with the control rod drive system.

"Due to the reactor protection system actuation while critical, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B).

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."