Event Notification Report for June 22, 2024

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
06/21/2024 - 06/22/2024

EVENT NUMBERS
57187

Power Reactor
Event Number: 57187
Facility: Vogtle 1/2
Region: 2     State: GA
Unit: [2] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: Matthew Henson
HQ OPS Officer: Karen Cotton-Gross
Notification Date: 06/22/2024
Notification Time: 11:44 [ET]
Event Date: 06/22/2024
Event Time: 07:28 [EDT]
Last Update Date: 06/22/2024
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
Suggs, LaDonna (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R N 0 Hot Standby 0 Hot Standby
Event Text
MANUAL ACTUATION OF REACTOR PROTECTION SYSTEM (RPS)

The following information was provided by the licensee via email:

"At 0728 EDT on 06/22/2024, with Unit 2 in Mode 3 at zero percent power and the reactor trip breakers closed, a manual actuation of the RPS was initiated during the withdrawal of the shutdown rods in preparation for Mode 2. This was procedurally directed due to a shutdown rod being misaligned from the other rods in the bank due to a malfunction.

"Units 1, 3 and 4 were not affected.

"Due to the manual actuation of the RPS, this event is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(iv)(A).

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."