Skip to main content

Event Notification Report for July 01, 2020

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
06/30/2020 - 07/01/2020

EVENT NUMBERS
547635476154807

Agreement State
Event Number: 54763
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: Cleveland Clinic Florida - Weston
Region: 1
City: Weston   State: FL
County:
License #: 3871-1
Agreement: Y
Docket:
NRC Notified By: David Pieski
HQ OPS Officer: Brian P. Smith
Notification Date: 07/06/2020
Notification Time: 11:40 [ET]
Event Date: 07/01/2020
Event Time: 00:00 [EDT]
Last Update Date: 07/06/2020
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
ANTHONY DIMITRIADIS (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following was received via email:

"A 98 microCurie I-125 breast cancer localization seed (titanium encapsulated) was inadvertently cut in half during its extraction from a patient. All portions of seed presumably removed and lavage performed. A pancake probe was used at tissue surface prior to tissue closure and measured 200 microR/hr. Tissue entry point was closed and re-surveyed at some later time with a measurement of 10 microR/hr. Post recovery, patient was apprised of the event and initiated a 10-day KI treatment plan. [The Radiation Safety Regional Health Director] is in consultation with the dose calibrator manufacturer and seed manufacturer (Team Best) in order to better calculate activity of recovered seed portions and subsequently compare to initial, inserted activity. The difference will yield activity remaining in the patient."

Florida Incident Number: FL20-073

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Power Reactor
Event Number: 54761
Facility: Fermi
Region: 3     State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: Jeffrey Myers
HQ OPS Officer: Kerby Scales
Notification Date: 07/02/2020
Notification Time: 02:01 [ET]
Event Date: 07/01/2020
Event Time: 23:05 [EDT]
Last Update Date: 07/02/2020
Emergency Class: Non Emergency
10 CFR Section:
50.72(b)(3)(iv)(A) - Valid Specif Sys Actuation
Person (Organization):
PATRICIA PELKE (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Refueling 0 Refueling
Event Text
LOSS OF OFFSITE POWER - AUTO INITIATION OF EMERGENCY DIESEL GENERATOR

"At 2305 EDT on July 1, 2020, while in Mode 5 for Refueling Outage 20 with no core alterations in progress, Fermi 2 experienced a loss of Division 2 offsite power (345 kV) which resulted in a valid automatic initiation of the Division 2 Emergency Diesel Generators (EDG) 13 and 14. EDG 13 and 14 started as expected to supply their associated busses. Division 1 offsite power remains operable and powering the Division 1 Residual Heat Removal (RHR) system in Shutdown Cooling (SDC) mode of operation. Division 1 EDGs 11 and 12 remain operable and available.

"The cause of the loss of Division 2 offsite power is under review and has preliminarily been determined to be caused by Mayfly accumulation in and around the Division 2 (345 kV) switchyard. Actions have been put in place to minimize and deter Mayflies from gathering near plant switchyards.

"All systems responded as expected for the loss of Division 2 offsite power and no loss of SDC occurred. There was no impact to the health and safety of the public or plant personnel.

"The NRC Resident Inspector has been notified.

"The event is reportable pursuant to 10 CFR 50.72(b)(3)(iv)(A), as a valid specified system actuation."


Agreement State
Event Number: 54807
Rep Org: MA RADIATION CONTROL PROGRAM
Licensee: Town of Littleton
Region: 1
City: Attleboro   State: MA
County:
License #: N/A
Agreement: Y
Docket:
NRC Notified By: Zara Rejaee
HQ OPS Officer: Bethany Cecere
Notification Date: 07/30/2020
Notification Time: 12:35 [ET]
Event Date: 07/01/2020
Event Time: 00:00 [EDT]
Last Update Date: 09/02/2020
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
BRICE BICKETT (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
Event Text


EN Revision Imported Date : 9/3/2020

EN Revision Text: AGREEMENT STATE REPORT - ABANDONED RADIOACTIVE SCRAP METAL

The following information was received via email:

"On 7/1/2020, Massachusetts Radiation Control Program was informed by Schnitzer Steel Industries, Inc., that a scrap metal shipment from Town of Littleton Transfer Station in Littleton, MA set off the radiation monitor alarm. The vehicle was redirected back to Littleton Transfer Station for follow-up survey and mitigation in accordance with MA RCP DOT Special Permit 10656 MA-MA-20-01.

"On 7/6/20, the material was identified and segregated from the scrap metal load by an independent radiation consultant. The radioactive material discovered was radium-226 Aircraft gauge. Device is intact and not leaking as a wipe test was done by radiation consultant. A Ludlum Model 9DP-1 ion chamber was used for direct measurements on the instrument. The dose rate at 6 inches from the instrument was 1 mR/hr. Dose rate outside of drum is less than 300 microR/hr. The radium-226 activity was estimated to be approximately 31.6 microCuries based on the dose rate measured.

"The RAM material is being stored in safe secure storage away from people and labeled as radioactive material held for proper disposal.

"This activity meets the 30-day event report requirement for lost or abandoned radioactive material greater than 10 times the quantities specified in 10 CFR 20 Appendix C, or the Massachusetts equivalent, 105 CMR 120.297 Appendix C, which is ten times reportable quantity for radium-226 (1 microCurie).

"The Massachusetts Radiation Control Program considers this event to be open until proper disposal of this instrument is confirmed."

Event Docket No.: MA 19-4216

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


* * * UPDATE FROM ZARA REJAEE TO DONALD NORWOOD AT 1549 EDT ON 9/2/2020 * * *

The following information was received via E-mail and is the Agency's (Massachusetts Radiations Control Program) final update to this report:

"1). Event Cause: Device abandoned or discarded by person(s) unknown.

"2). Corrective Action: Device transferred for proper disposal at licensed facility.

"3). Manufacturer of Source or Device: Not Available / Not Indicated. Device found in scrap metal load.

"4). No additional information expected by Agency.

"5). Agency considers this event to be closed."

Notified R1DO (Ambrosini), NMSS Events Notification E-mail group and ILTAB E-mail group.