Skip to main content

Event Notification Report for July 13, 2019

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/12/2019 - 07/13/2019

EVENT NUMBERS
54174

Agreement State
Event Number: 54174
Rep Org: GEORGIA RADIOACTIVE MATERIAL PGM
Licensee: RAYONIER ADVANCED MATERIALS, LLC
Region: 1
City: COLLINS   State: GA
County:
License #: 381-1
Agreement: Y
Docket:
NRC Notified By: ROGER WILSON
HQ OPS Officer: JEFFREY WHITED
Notification Date: 07/19/2019
Notification Time: 10:31 [ET]
Event Date: 07/13/2019
Event Time: 00:00 [EDT]
Last Update Date: 07/22/2019
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
JOSEPH DEBOER (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - DENSITY GAUGE SHUTTER FAILED IN OPEN POSITION

The following information was received via E-mail:

"The shutter on a SVP generator [chlorine dioxide] ClO2 density meter failed in the open position. This failure was identified and verified on Saturday, 7/13/19. Berthold inspected the gauge while they were on site on 7/19/19 and are scheduled to come in on the next C mill outage to replace the shield. Outage is tentatively scheduled for 10/9/19. The gauge shutter normally operates in the open position so the failure poses no safety risk during normal operations.

"The SVP generator density meter is Rayonier instrument loop no. 507-081. The source is Cesium-137, 500 mCi, model 2623-100, serial no. ED350A in a LB7440 housing."


* * * UPDATE FROM ROGER WILSON TO DONALD NORWOOD AT 1358 EDT ON 7/19/2019 * * *

The following information was received via E-mail:

In the course of planning for Berthold to come on site to repair the SVP generator density meter shutter, it was discovered that our records on the source were in error. The source is model 2623 Cesium-137, 10 mCi, serial no. EA350A NOT 500 mCi, serial no. ED350.

Notified R1DO (Deboer) and NMSS Events Notification E-mail group.

* * * UPDATE FROM LESLINES LEVEQUE TO ANDREW WAUGH AT 1405 EDT ON 7/22/2019 * * *

The following information was received via E-mail:

"The broken shutter at the SVP salt cake density meter was addressed on 7/18/19. Berthold came on site and replaced the shield with a new one, moving the source from the old gauge into the new. The new shield is a model LB 7440-F-CR device, serial no. 37625-13606."