Skip to main content

Event Notification Report for May 03, 2019

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/02/2019 - 05/03/2019

EVENT NUMBERS
54046540475404854043

Power Reactor
Event Number: 54046
Facility: TURKEY POINT
Region: 2     State: FL
Unit: [3] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: CHRISTOPHER TRENT
HQ OPS Officer: CATY NOLAN
Notification Date: 05/03/2019
Notification Time: 16:43 [ET]
Event Date: 05/03/2019
Event Time: 08:52 [EDT]
Last Update Date: 05/03/2019
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
JAMIE HEISSERER (R2DO)
FFD GROUP (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
4 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS-FOR-DUTY REPORT

A non-licensed contract supervisor had a confirmed positive during a for-cause fitness-for-duty test. The individual's authorization for site access has been terminated.

The NRC Resident has been notified.


Power Reactor
Event Number: 54047
Facility: MCGUIRE
Region: 2     State: NC
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: DAVID PUNCH
HQ OPS Officer: JEFFREY WHITED
Notification Date: 05/03/2019
Notification Time: 19:00 [ET]
Event Date: 05/03/2019
Event Time: 15:54 [EDT]
Last Update Date: 05/03/2019
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JAMIE HEISSERER (R2DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 100 Power Operation 0 Hot Standby
Event Text
AUTOMATIC REACTOR TRIP ON OVER TEMPERATURE DELTA TEMPERATURE

"At 1554 EDT on 5/3/19, with Unit 1 in Mode 1 at approximately 100 percent power, the reactor automatically tripped on Over Temperature Delta Temperature following a pressure transient in the Reactor Coolant System. The trip was uncomplicated with all systems responding normally post trip. Operations manually started the motor driven auxiliary feedwater pumps and has stabilized the plant. Decay heat is being removed by the condenser. Unit 2 is not affected.

"Due to Reactor Protection System actuation while critical and actuation of the motor driven auxiliary feedwater pumps, this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(iv)(B) and an 8-hour non-emergency notification per 10 CFR 50.72(b)(3)(iv)(A).

"There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."

Unit 1 is in a normal electrical lineup.

Prior to the automatic trip, the backup pressurizer heaters were in service as is normal during power ascension. The pressure transient started when the backup heaters were in the process of being removed from service.

The licensee notified the NRC Resident Inspector.


Agreement State
Event Number: 54048
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: SANTA CLARA HOSPITAL
Region: 4
City: SAN JOSE   State: CA
County:
License #: 0741
Agreement: Y
Docket:
NRC Notified By: JOHN FASSELL
HQ OPS Officer: JEFFREY WHITED
Notification Date: 05/03/2019
Notification Time: 18:37 [ET]
Event Date: 05/03/2019
Event Time: 00:00 [PDT]
Last Update Date: 05/03/2019
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
GREG WERNER (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - Y-90 UNDERDOSAGE REPORT

The following was received via e-mail:

"At 1138 PDT on 05/03/2019, the [California Radiation Control Program] received a phone call from the licensee's [Radiation Safety Officer] RSO providing the initial report on a Y-90 radioembolization underdose. Only 76 percent of the planned dose was provided to the organ of interest with the rest having leaked out because of a faulty stopcock assembly. The leak area was contained and cleaned up. All decontamination is complete and the only effect is the underdose to the patient."

CA 5010 Number: 050319

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Agreement State
Event Number: 54043
Rep Org: SC DEPT OF HEALTH & ENV CONTROL
Licensee: NEW-INDY CONTAINERBOARD, LLC
Region: 1
City: CATAWBA   State: SC
County:
License #: 030
Agreement: Y
Docket:
NRC Notified By: ANDREW ROXBURGH
HQ OPS Officer: JEFFREY WHITED
Notification Date: 05/03/2019
Notification Time: 10:55 [ET]
Event Date: 05/03/2019
Event Time: 06:00 [EDT]
Last Update Date: 05/03/2019
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
ERIN CARFANG (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - BROKEN SHUTTER

The following was received via e-mail:

"On May 3, 2019, the Department [South Carolina Department of Health and Environmental Control] was notified by the licensee that a shutter had broken on one of its gauges while attempting to close the shutter because of a sprinkler failure that was soaking the area where the gauge was mounted. The gauge is a Kay-Ray Model 70628 containing 10 mCi of Cesium 137. The licensee has contacted Systems Services who is specifically licensed to repair the damaged shutter. The [Radiation Safety Officer] RSO stated that he has performed a radiation survey around the gauge where individuals normally work and the radiation readings are background. Access to the gauge has been restricted and the area has been roped off by the RSO until the service provider comes to fix the shutter. The service provider is scheduled to come May 7, 2019."