Event Notification Report for February 10, 2019

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/09/2019 - 02/10/2019

EVENT NUMBERS
53871

Agreement State
Event Number: 53871
Rep Org: KENTUCKY DEPT OF RADIATION CONTROL
Licensee: NORTH AMERICAN STAINLESS
Region: 1
City: GHENT   State: KY
County:
License #: 201-499-57
Agreement: Y
Docket:
NRC Notified By: ANJAN (AJ) BHATTACHARYYA
HQ OPS Officer: BRIAN P. SMITH
Notification Date: 02/13/2019
Notification Time: 12:00 [ET]
Event Date: 02/10/2019
Event Time: 00:00 [EST]
Last Update Date: 02/13/2019
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
MARC FERDAS (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - GAUGE DEVICE DAMAGED BY MOLTEN STEEL

The following report was received from the Commonwealth of Kentucky via fax:

"KY RHB [Kentucky Radiation Health Branch] was notified by telephone on 2/12/2019 at 1315 EST by a representative from a specifically licensed facility, North American Stainless, that on Sunday, 2/10/2019, North American Stainless encountered a 'breakout' when molten steel escaped and poured onto billet caster molds located below a 'tundish' filled with molten steel. One of the molds attached to a Berthold Model No. LB300ML Mold Level Control fixed gauging device, serial number 9415, containing 1 mCi (37 MBq) Co-60 (source serial number 1819-11-15) was covered with the liquid steel encapsulating the source holder. After the steel and mold had cooled, it was freed on 2/12/2019 and segregated. The encapsulating steel rendered the device on-off mechanism (shutter) inoperable. Initial readings taken with a Ludlum 2241-3 survey instrument measured 6.25 mR/hr measured 12 inches directly in front of the window, and 1.25 mR/hr measured 90 degrees from the line of the window measured at a distance of 12 inches. Readings at the back of the source holder were 132 microR/hr measured at a distance of 12 inches. No overexposures have been reported. On 2/12/2019, Radiametric Technologies, a service provider located in Lorain, Ohio, requested reciprocal approval and was granted reciprocity on 2/13/2019 in order to assess and remediate the situation.

"The fixed gauging device involved in the incident was recently leak tested (test conducted on 7/31/2018) by Suntrac Services, League City TX. Radiametric Technologies, Lorain OH, recently tested the source holder on-off mechanism (1/31/2019) and it was found to be in good working order. North American Stainless is reviewing the incident to avoid future incidents involving 'tundish' failures. A full report will be provided once the remediation is complete.

"Reporting criteria in 10 CFR 30.50(b)(2)."

KY Report #KY190001