Event Number: 53462
Facility: BROWNS FERRY
Region: 2     State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: MARK MOEBES
HQ OPS Officer: RICHARD SMITH
Notification Date: 06/20/2018
Notification Time: 11:39 [ET]
Event Date: 06/20/2018
Event Time: 10:03 [CDT]
Last Update Date: 06/20/2018
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
GERALD MCCOY (R2DO)
BRIAN HOLIAN (NRR)
CATHY HANEY (R2RA)
JEFF GRANT (IRD)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
3 N Y 94 Power Operation 94 Power Operation
Event Text
NOTIFICATION OF UNUSUAL EVENT DECLARED DUE TO TOXIC GAS RELEASE

On June 20, 2018 at 1003 CDT, the licensee declared a Notification of Unusual Event based on Emergency Action Level (EAL) 6.5.U, toxic gas release on site.

The Notification of Unusual Event was terminated at 1025 CDT.

The toxic gas release occurred when site personnel were filling a fire suppression carbon dioxide (CO2) tank outside the diesel generator building. The relief valve in the common diesel generator room for Unit 1 and 2 diesel generators inadvertently lifted causing a toxic gas environment by releasing CO2 into the room. The licensee terminated the tank fill stopping the release of CO2, and with the door to the room being opened, the gas cleared in about 20 minutes.

The licensee has notified the NRC Resident Inspector.

Notified DHS SWO, FEMA Ops, DHS NICC, FEMA NWC (email) and NuclearSSA (email).


Power Reactor
Event Number: 53463
Facility: CLINTON
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ROBERT RUSH
HQ OPS Officer: RICHARD SMITH
Notification Date: 06/20/2018
Notification Time: 17:51 [ET]
Event Date: 06/20/2018
Event Time: 11:45 [CDT]
Last Update Date: 06/20/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
KENNETH RIEMER (R3DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 98 Power Operation 98 Power Operation
Event Text
HIGH-PRESSURE CORE SPRAY INOPERABLE

"On June 20, 2018, at 1145 hours (CDT), during panel walkdown, it was identified that High-Pressure Core Spray (HPCS) injection valve 1E22F004 was in the open position. Valve 1E22F004 is normally closed for containment integrity purposes. Operations personnel verified that the valve was open locally and that the plant computer indicated the valve is in the 'not closed' position. No alarms or status lamps indicated why the valve would be open and there was no valid demand signal. Reactor power, pressure, level, and feedwater parameters remain steady and unchanged, with no indication of HPCS injection having occurred or in progress.

"A low-water level signal, or a high drywell pressure signal, or manual operation initiates HPCS. When a high-water level in the reactor vessel is detected, HPCS injection is automatically stopped by a signal to close injection valve 1E22F004. With valve 1E22F004 in the open position without a demand signal, closure on a high reactor water level condition was not assured. Therefore, HPCS was declared inoperable. The following Technical Specifications were entered: 3.5.1, Emergency Core Cooling Systems (ECCS) - Operating and 3.6.1.3, Primary Containment Isolation Valves (PCIVs).

"Subsequently, HPCS injection valve 1E22F004 was observed to be cycling without operator action. The valve was deactivated in the closed position to assure the containment isolation function.

"The cause of valve 1E22F004 cycling without operator action is under investigation.

"HPCS is a single train safety system that consists of a single motor-driven pump, a spray sparger in the reactor vessel, and associated piping, valves, controls and instrumentation. HPCS is part of the ECCS network, which also includes Low-Pressure Core Spray, Low-Pressure Coolant Injection, and the Automatic Depressurization system.

"This event is being reported as an 8-hour non-emergency notification per 10 CFR 50.72(b)(3)(v) as, 'Any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to: (A) Shut down the reactor and maintain it in a safe shutdown condition; (B) Remove residual heat; (C) Control the release of radioactive material; or (D) Mitigate the consequences of an accident.'"

The licensee notified the NRC Resident Inspector.


Agreement State
Event Number: 53465
Rep Org: OK DEQ RAD MANAGEMENT
Licensee: TULSA GAMMA RAY, INC.
Region: 4
City: TULSA   State: OK
County:
License #: OK-17178-02
Agreement: Y
Docket:
NRC Notified By: KEVIN SAMPSON
HQ OPS Officer: RICHARD SMITH
Notification Date: 06/21/2018
Notification Time: 12:07 [ET]
Event Date: 06/20/2018
Event Time: 16:15 [CDT]
Last Update Date: 06/21/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
MICHAEL HAY (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - RADIOGRAPHY CAMERA CRANK FAILURE

The following was received from the state of Oklahoma via phone call and E-mail:

On June 20, 2018, at approximately 1615 CDT, Tulsa Gamma Ray, Inc. (License # OK-17178-02) had a failure of the industrial radiography camera leaving the source exposed. The radiography camera is a model QSA 880D, source Spec T5, source strength unknown. The crank was a Sentinel SAN 882 Serial Number 15997.

The licensee was authorized to perform a source recoveries, and the Radiation Safety Officer (RSO) successfully recovered the source. The RSO received a dose of 140 mRem as indicated on the RSO's pocket dosimeter. No other exposure information was provide at the time of the report.

The state of Oklahoma will provide more information on this event as it becomes available. A State report number will be provided at that time.