Skip to main content

Event Notification Report for June 14, 2018

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
06/13/2018 - 06/14/2018

EVENT NUMBERS
5345854671

Agreement State
Event Number: 53458
Rep Org: UTAH DIVISION OF RADIATION CONTROL
Licensee: UNIVERSITY OF UTAH RADIATION SAFETY
Region: 4
City: SALT LAKE CITY   State: UT
County:
License #: UT 1800001
Agreement: Y
Docket:
NRC Notified By: SPENCER WICKHAM
HQ OPS Officer: ANDREW WAUGH
Notification Date: 06/15/2018
Notification Time: 16:55 [ET]
Event Date: 06/14/2018
Event Time: 00:00 [MDT]
Last Update Date: 08/17/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
NICK TAYLOR (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

The following was received from the State of Utah via email:

"The licensee informed the State of Utah they are evaluating a potential medical event. A patient was implanted with 54 Pd-103 seeds in the prostate under ultrasound guidance. Per standard practice, the patient returned for a CT scan to verify the placement of the seeds. The CT scan revealed that 32 of the seeds had been implanted outside of the prostate. In addition, only 51 seeds were located, likely the result of 3 seeds being passed via stool. They believe that several additional seeds are in the rectum and will be passed following an enema."

Utah Event Report ID No.: UT180003


* * * UPDATE ON 8/17/2018 AT 1106 EDT FROM TIM BUTLER TO ANDREW WAUGH * * *

The following update was received from the State of Utah via email:

"The licensee reported a medical event involving a patient treated for prostate cancer. The treatment included implanting 54 Pd-103 brachytherapy [seeds] (Theragenics, Theraseed) containing a total activity of 4 GBq (108.167 mCi), in the patient's prostate for a prescribed therapeutic radiation dose of 12,500 cGy (rad). The prostate gland only received approximately 1,000 cGy (rad). The seeds were implanted on June 14, 2018 under ultrasonic guidance. On June 15, 2018, the patient returned to the facility for a post implant CT scan. The scan showed that the implanted seeds, although in an appropriate pattern, were placed outside the intended target. The Licensee's Radiation Oncology group determined that an additional quality assurance review was warranted. The State performed a reactive inspection during the week of June 15, 2018. The cause was determined to be human error. An unintended dose to the rectum of approximately 18,677 cGy (rad) was received, where no dose was anticipated. Corrective actions included changes to the prostate brachytherapy protocol to incorporate an additional step to ensure the medical physicist and authorized user clearly identifies the prostate gland and the surrounding anatomy. The treatment will be cancelled if the prostate gland and surrounding anatomy cannot be visualized adequately."

Notified R4DO (Deese), INES Coordinator (Milligan), and NMSS Event Notifications via email.

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


Agreement State
Event Number: 54671
Rep Org: COLORADO DEPT OF HEALTH
Licensee: LDS CHURCH - ARVADA
Region: 4
City: ARVADA   State: CO
County:
License #: GL002098
Agreement: Y
Docket:
NRC Notified By: KATHRYN MOTE
HQ OPS Officer: CATY NOLAN
Notification Date: 04/16/2020
Notification Time: 15:34 [ET]
Event Date: 06/14/2018
Event Time: 00:00 [MDT]
Last Update Date: 04/16/2020
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
JEFFREY JOSEY (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
LAURA PEARSON (ILTAB)
Event Text
AGREEMENT STATE REPORT - LOST TRITIUM EXIT SIGNS

The following is a summary of information received from the State of Colorado via e-mail:

The licensee is unable to locate two tritium exit signs each with an activity of 10.0 Ci. The two exit signs were not able to be accounted for during annual registration.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf