Skip to main content

Event Notification Report for May 30, 2018

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/29/2018 - 05/30/2018

EVENT NUMBERS
53436534375343354624

Agreement State
Event Number: 53436
Rep Org: PA BUREAU OF RADIATION PROTECTION
Licensee: UNIVERSAL PRESSURE PUMPING, INC.
Region: 1
City: MEADVILLE   State: PA
County:
License #: PA-1446
Agreement: Y
Docket:
NRC Notified By: JOHN CHIPPO
HQ OPS Officer: DONALD NORWOOD
Notification Date: 06/01/2018
Notification Time: 11:39 [ET]
Event Date: 05/30/2018
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
GLENN DENTEL (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
AGREEMENT STATE REPORT - IN-LINE DENSITY GAUGE STUCK SHUTTER

The following information was received via E-mail:

"On May 31, 2018, the Department [PA DEP Bureau of Radiation Protection] was notified by the licensee that a malfunction of a roll pin on a shutter handle occurred at a temporary jobsite in Eighty Four, Pennsylvania. It is initially reportable per 10 CFR 30.50(b)(2).

"A roll pin, which holds the shutter handle to the shutter shaft on a Berthhold Model LB 8010 in-line density gauge containing 20 milliCuries of cesium-137 became sheared off during an attempt to move the shutter to the open position, rendering the gauge unusable. The gauge is currently being stored at their Punxsutawney, PA location. The shutter is in the closed position and the gauge is out of service awaiting repair from the manufacturer. There was no other damage to the gauge. No overexposures have occurred.

"Radionuclide: Cs-137
Manufacturer: Berthold
Model: LB 8010
Serial Number: 10485
Activity: 20 mCi

"The cause of the event has been attributed to normal wear and tear on the gauge. A reactive inspection is planned by the Department."

PA Event Report ID No: PA180013


Non-Agreement State
Event Number: 53437
Rep Org: CHRISTIANA CARE HOME SERVICES, INC
Licensee: CHRISTIANA CARE HOME SERVICES, INC.
Region: 1
City: NEWARK   State: DE
County:
License #:
Agreement: N
Docket:
NRC Notified By: XIAOQIAN WEN
HQ OPS Officer: JEFF HERRERA
Notification Date: 06/01/2018
Notification Time: 13:05 [ET]
Event Date: 05/30/2018
Event Time: 00:00 [EDT]
Last Update Date: 06/01/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
GLENN DENTEL (R1DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
Event Text
LOST IODINE-125 SEEDS

On 5/30/2018 a physicist for Christiana Care Home Services discovered that 50 Iodine-125 seeds were missing from the Hot Lab. The licensee began investigating to determine what happened to the seeds. The licensee determined that the seeds had been initially brought into the Hot Lab on 2/6/2018. The licensee believes that on 3/16/2018 an employee from Occupational Safety picked up empty trays from the Hot Lab to recycle them as part of their recycling program and that the Iodine-125 seeds may have been on two of the trays picked up. The trays were taken to a trailer where normal scrap metal is placed and were later picked up by the recycling company.

The licensee believes, but could not confirm that the recycling company picked up the trays along with the seeds which were then taken to universal waste disposal. The licensee interviewed the occupational safety individual and the individual could not confirm that he saw any Iodine-125 seeds in the trays he placed into the recycling box. The licensee has also contacted the recycling company to determine if the boxes can be retrieved, however, the recycling company stated that the box of scrap metal could not be retrieved at this point.

The licensee contacted the Iodine-125 vendor to confirm that the inventory that they have in their possession was correct. The quantity of seeds missing consisted of 50 Iodine-125 seeds with a total activity of 6 millicuries.

THIS MATERIAL EVENT CONTAINS A "CATEGORY 3" LEVEL OF RADIOACTIVE MATERIAL

Category 3 sources, if not safely managed or securely protected, could cause permanent injury to a person who handled them, or were otherwise in contact with them, for some hours. It could possibly - although it is unlikely - be fatal to be close to this amount of unshielded radioactive material for a period of days to weeks. These sources are typically used in practices such as fixed industrial gauges involving high activity sources (for example: level gauges, dredger gauges, conveyor gauges and spinning pipe gauges) and well logging. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf


Non-Power Reactor
Event Number: 53433
Rep Org: UNIV OF MISSOURI-COLUMBIA
Licensee: UNIVERSITY OF MISSOURI
Region: 0
City: COLUMBIA   State: MO
County: BOONE
License #: R-103
Agreement: N
Docket: 05000186
NRC Notified By: SEAN SCHAEFER
HQ OPS Officer: THOMAS KENDZIA
Notification Date: 05/31/2018
Notification Time: 08:54 [ET]
Event Date: 05/30/2018
Event Time: 07:10 [CDT]
Last Update Date: 05/31/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
GEOFFERY WERTZ (PM)
ELIZABETH REED (NPR)
Event Text
TECHNICAL SPECIFICATION DEVIATION

"On May 30, 2018, at 07:10 CST, with the reactor operating at 10 MW in the automatic control mode, MURR [University of Missouri Research Reactor] was shut down due to a failure of the Control Rod Operate Switch 1S4 to move the shim control blades in the inward direction. The Reactor Safety (Scram) and Rod-Run-In Systems were unaffected by this failure and remained operational and would automatically and manually initiate, if required. This email is a required notification per MURR TS [Technical Specification] 6.6.c(1) to report to the NRC Operations Center that an Abnormal Occurrence, as defined by MURR TS 1.1.b, has occurred. MURR was not in compliance with all of the Limiting Conditions for Operations (LCOs) as established in Section 3.0. Specifically, MURR was not in compliance with TS 3.2.a, which states, All control blades, including the regulating blade, shall be operable during reactor operation. Control Rod Operate Switch 1S4 was replaced and retest was conducted satisfactorily, which included verifying inward and outward movement of all 4 shim control blades. Authorization was received from the Reactor Facility Director, as required by TS 6.6.c(4), to restart the reactor and resume 10 MW operation. A detailed event report will follow within 14 days as required by MURR TS 6.6.c(3)."

The failure was identified during scheduled testing and the reactor was shutdown by manual Scram in accordance with procedures.

The licensee notified the NRC Research and Test Reactor Project Manager (Wertz).


Agreement State
Event Number: 54624
Rep Org: COLORADO DEPT OF HEALTH
Licensee: CURTIS HOTEL
Region: 4
City: Denver   State: CO
County:
License #: GL002245
Agreement: Y
Docket:
NRC Notified By: KATHRYN MOTE
HQ OPS Officer: BRIAN P. SMITH
Notification Date: 03/30/2020
Notification Time: 17:40 [ET]
Event Date: 05/30/2018
Event Time: 00:00 [MDT]
Last Update Date: 03/30/2020
Emergency Class: NON EMERGENCY
10 CFR Section:
AGREEMENT STATE
Person (Organization):
VINCENT GADDY (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST TRITIUM EXIT SIGN

The following was summarized from the email received from the state of Colorado:

One tritium exit sign, containing 10.0 Curies, was determined lost after renovation.

Initial Date Reported: 5/30/18

Final Decision Material Lost Date: 5/30/18

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf