Skip to main content

Event Notification Report for May 22, 2018

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/21/2018 - 05/22/2018

EVENT NUMBERS
534185341653419

Power Reactor
Event Number: 53418
Facility: OYSTER CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-2
NRC Notified By: BRYAN EAGAN
HQ OPS Officer: THOMAS KENDZIA
Notification Date: 05/22/2018
Notification Time: 15:36 [ET]
Event Date: 05/22/2018
Event Time: 10:28 [EDT]
Last Update Date: 05/22/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
ANTHONY DIMITRIADIS (R1DO)
FFD GROUP (EMAIL)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY - LICENSED OPERATOR CONFIRMED POSITIVE TEST

"A licensed operator had a confirmed positive test during a random fitness-for-duty test. The individual was not performing licensed duties. The individual's qualifications and plant access were removed. A work performance investigation has been completed. Work performed by the individual has been verified to be compliant with all standards.

"The NRC Resident Inspector has been notified."


Power Reactor
Event Number: 53416
Facility: COOPER
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: TERREL HIGGINS
HQ OPS Officer: THOMAS KENDZIA
Notification Date: 05/22/2018
Notification Time: 13:36 [ET]
Event Date: 05/22/2018
Event Time: 09:00 [CDT]
Last Update Date: 05/22/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
JASON KOZAL (R4DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
UNPLANNED PUBLIC NOTIFICATION DURING A DRILL

"On 05/22/2018, Cooper Nuclear Station (CNS) was conducting an Emergency Response Organization (ERO) drill which included state and local involvement. At approximately 09:00 CST Nebraska Emergency Management Agency (NEMA) inadvertently broadcasted CNS' declaration of a Notice of Unusual Event for the drill over the public scanner. This resulted in various members of the public or news media inquiring about the perceived event or posting erroneous information via Twitter, television news outlets, newspapers, and radio stations. These news outlets have been informed that CNS was conducting a drill and do not intend to release any stories regarding this event. There is no evidence of a formal news release at this time. However, due to the uncontrolled source of the information, the determination was made to make this report.

"This unplanned media event is a 4 hour report, in accordance with 10CFR50.72(b)(2)(xi). This event is not significant with respect to the health and safety of the public.

"The licensee notified the NRC Resident Inspector."


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 53419
Facility: BEAVER VALLEY
Region: 1     State: PA
Unit: [1] [] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: JIM DOUGHERTY
HQ OPS Officer: THOMAS KENDZIA
Notification Date: 05/22/2018
Notification Time: 18:38 [ET]
Event Date: 05/22/2018
Event Time: 12:56 [EDT]
Last Update Date: 06/21/2018
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS 50.72(b)(3)(ii)(B) - UNANALYZED CONDITION 50.72(b)(3)(v)(B) - POT RHR INOP 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
ANTHONY DIMITRIADIS (R1DO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
GAS VOIDS DISCOVERED IN BOTH TRAINS OF LOW HEAD SAFETY INJECTION

"On 5/22/2018, while operating at approximately 100 percent power, Ultrasonic Testing of the Beaver Valley Power Station (BVPS) Unit 1 Low Head Safety Injection (LHSI) pump suction piping identified gas voids in excess of the acceptable limit for void volume. Both trains of LHSI were declared inoperable. Technical Specification (TS) 3.5.2 for both trains of the LHSI system was entered along with TS 3.0.3 which requires the initiation of a plant shutdown. Time of TS entry was 12:56 (EDT).

"Plant shutdown was commenced at 15:56 (EDT) in accordance with plant procedures.

"At 15:59 (EDT) Train 'A' LHSI was restored to operable status, TS 3.0.3 Action was exited and the power reduction was stopped at approximately 99 percent.

"At 17:43 (EDT) Train 'B' LHSI was restored to operable status, TS 3.5.2 Actions were exited.

"This is reportable per 10 CFR 50.72(b)(3)(ii) Unanalyzed Condition, 10 CFR 50.72(b)(3)(v) Event or Condition that Could Have Prevented the Fulfillment of a Safety Function and 10 CFR 50. 72(b )(2)(i) TS Required Shutdown.

"The NRC Resident Inspector has been notified."

* * * RETRACTION ON 6/21/18 AT 1535 EDT FROM SHAWN KEENER TO RICHARD SMITH * * *

"Further engineering evaluation has determined that the gas voids that existed at the time of discovery would not have rendered the LHSI [Low Head Safety Injection] system inoperable if it were required to actuate. The engineering evaluation concluded that filling of the containment sump during a Design Basis Accident would result in a void volume reduction such that the void in the LHSI suction piping would not be large enough to significantly impact the operability of the system. Therefore, the system remained operable but degraded. No TSs [Technical Specifications] were required to be entered and no shutdown was required. As such, all three reporting criteria do not apply and are being retracted.

"The NRC Resident Inspector has been notified."

Notified R1DO (Burritt).